UNPKG

zigbee-herdsman

Version:

An open source ZigBee gateway solution with node.js.

70 lines (69 loc) 3.57 kB
export enum Status { /** Operation was successful. */ SUCCESS = 0x00, /** Operation was not successful. */ FAILURE = 0x01, /** The sender of the command does not have authorization to carry out this command. */ NOT_AUTHORIZED = 0x7e, RESERVED = 0x7f, /** * The command appears to contain the wrong fields, as detected either by the presence of one or more invalid * field entries or by there being missing fields. * Command not carried out. Implementer has discretion as to whether to return this error or INVALID_FIELD. */ MALFORMED_COMMAND = 0x80, // UNSUP_CLUSTER_COMMAND = 0x81, DEPRECATED in favor of UNSUP_COMMAND /** The specified command is not supported on the device. Command not carried out. */ UNSUP_COMMAND = 0x81, UNSUP_GENERAL_COMMAND = 0x82, // DEPRECATED in favor of UNSUP_COMMAND UNSUP_MANUF_CLUSTER_COMMAND = 0x83, // DEPRECATED in favor of UNSUP_COMMAND UNSUP_MANUF_GENERAL_COMMAND = 0x84, // DEPRECATED in favor of UNSUP_COMMAND /** At least one field of the command contains an incorrect value, according to the specification the device is implemented to. */ INVALID_FIELD = 0x85, /** The specified attribute does not exist on the device. */ UNSUPPORTED_ATTRIBUTE = 0x86, /** * Out of range error or set to a reserved value. Attribute keeps its old value. * Note that an attribute value may be out of range if an attribute is related to another, * e.g., with minimum and maximum attributes. See the individual attribute descriptions for specific details. */ INVALID_VALUE = 0x87, /** Attempt to write a read-only attribute. */ READ_ONLY = 0x88, /** An operation failed due to an insufficient amount of free space available. */ INSUFFICIENT_SPACE = 0x89, DUPLICATE_EXISTS = 0x8a, // DEPRECATED in favor of SUCCESS /** The requested information (e.g., table entry) could not be found. */ NOT_FOUND = 0x8b, /** Periodic reports cannot be issued for this attribute.*/ UNREPORTABLE_ATTRIBUTE = 0x8c, /** The data type given for an attribute is incorrect. Command not carried out.*/ INVALID_DATA_TYPE = 0x8d, /** The selector for an attribute is incorrect. */ INVALID_SELECTOR = 0x8e, WRITE_ONLY = 0x8f, // DEPRECATED in favor of NOT_AUTHORIZED INCONSISTENT_STARTUP_STATE = 0x90, // DEPRECATED in favor of FAILURE DEFINED_OUT_OF_BAND = 0x91, // DEPRECATED in favor of FAILURE RESERVED14 = 0x92, ACTION_DENIED = 0x93, // DEPRECATED in favor of FAILURE /** The exchange was aborted due to excessive response time. */ TIMEOUT = 0x94, /** Failed case when a client or a server decides to abort the upgrade process. */ ABORT = 0x95, /** Invalid OTA upgrade image (ex. failed signature validation or signer information check or CRC check). */ INVALID_IMAGE = 0x96, /** Server does not have data block available yet. */ WAIT_FOR_DATA = 0x97, /** No OTA upgrade image available for the client. */ NO_IMAGE_AVAILABLE = 0x98, /** The client still requires more OTA upgrade image files to successfully upgrade. */ REQUIRE_MORE_IMAGE = 0x99, /** The command has been received and is being processed. */ NOTIFICATION_PENDING = 0x9a, HARDWARE_FAILURE = 0xc0, // DEPRECATED in favor of FAILURE SOFTWARE_FAILURE = 0xc1, // DEPRECATED in favor of FAILURE RESERVED15 = 0xc2, /** The cluster is not supported. */ UNSUPPORTED_CLUSTER = 0xc3, LIMIT_REACHED = 0xc4, // DEPRECATED in favor of SUCCESS }