zigbee-herdsman-converters
Version:
Collection of device converters to be used with zigbee-herdsman
338 lines • 18.9 kB
JavaScript
"use strict";
var __createBinding = (this && this.__createBinding) || (Object.create ? (function(o, m, k, k2) {
if (k2 === undefined) k2 = k;
var desc = Object.getOwnPropertyDescriptor(m, k);
if (!desc || ("get" in desc ? !m.__esModule : desc.writable || desc.configurable)) {
desc = { enumerable: true, get: function() { return m[k]; } };
}
Object.defineProperty(o, k2, desc);
}) : (function(o, m, k, k2) {
if (k2 === undefined) k2 = k;
o[k2] = m[k];
}));
var __setModuleDefault = (this && this.__setModuleDefault) || (Object.create ? (function(o, v) {
Object.defineProperty(o, "default", { enumerable: true, value: v });
}) : function(o, v) {
o["default"] = v;
});
var __importStar = (this && this.__importStar) || (function () {
var ownKeys = function(o) {
ownKeys = Object.getOwnPropertyNames || function (o) {
var ar = [];
for (var k in o) if (Object.prototype.hasOwnProperty.call(o, k)) ar[ar.length] = k;
return ar;
};
return ownKeys(o);
};
return function (mod) {
if (mod && mod.__esModule) return mod;
var result = {};
if (mod != null) for (var k = ownKeys(mod), i = 0; i < k.length; i++) if (k[i] !== "default") __createBinding(result, mod, k[i]);
__setModuleDefault(result, mod);
return result;
};
})();
Object.defineProperty(exports, "__esModule", { value: true });
exports.ubisysModernExtend = void 0;
const zigbee_herdsman_1 = require("zigbee-herdsman");
const exposes = __importStar(require("../lib/exposes"));
const m = __importStar(require("../lib/modernExtend"));
const exposes_1 = require("./exposes");
const logger_1 = require("./logger");
const modernExtend_1 = require("./modernExtend");
const NS = "zhc:ubisys";
exports.ubisysModernExtend = {
pollCurrentSummDelivered: (endpointId) => {
return m.poll({
key: "measurement",
defaultIntervalSeconds: 60,
option: exposes.options.measurement_poll_interval(),
poll: async (device) => {
const endpoint = device.getEndpoint(typeof endpointId === "number" ? endpointId : endpointId(device));
await endpoint.read("seMetering", ["currentSummDelivered"]);
},
});
},
addCustomClusterHvacThermostat: () => (0, modernExtend_1.deviceAddCustomCluster)("hvacThermostat", {
ID: 0x0201,
attributes: {
// H10
ubisysClassBTemperatureOffset: { ID: 0x0000, type: zigbee_herdsman_1.Zcl.DataType.INT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysReturnFlowTemperatureWeight: {
ID: 0x0001,
type: zigbee_herdsman_1.Zcl.DataType.INT8,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
ubisysRawOutdoorTemperature: { ID: 0x0002, type: zigbee_herdsman_1.Zcl.DataType.STRUCT, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysRawLocalTemperatureA: { ID: 0x0003, type: zigbee_herdsman_1.Zcl.DataType.STRUCT, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysRawLocalTemperatureB: { ID: 0x0004, type: zigbee_herdsman_1.Zcl.DataType.STRUCT, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysRawForwardFlowTemperature: {
ID: 0x0005,
type: zigbee_herdsman_1.Zcl.DataType.STRUCT,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
ubisysRawReturnFlowTemperature: {
ID: 0x0006,
type: zigbee_herdsman_1.Zcl.DataType.STRUCT,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
ubisysInstalledExtensions: { ID: 0x0007, type: zigbee_herdsman_1.Zcl.DataType.BITMAP64, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
// H1
ubisysTemperatureOffset: { ID: 0x0010, type: zigbee_herdsman_1.Zcl.DataType.INT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysDefaultOccupiedHeatingSetpoint: {
ID: 0x0011,
type: zigbee_herdsman_1.Zcl.DataType.INT16,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
ubisysVacationMode: { ID: 0x0012, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysRemoteTemperature: { ID: 0x0013, type: zigbee_herdsman_1.Zcl.DataType.INT16, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysRemoteTemperatureValidDuration: {
ID: 0x0014,
type: zigbee_herdsman_1.Zcl.DataType.UINT8,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
ubisysDetectOpenWindow: { ID: 0x0015, type: zigbee_herdsman_1.Zcl.DataType.BITMAP8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysOpenWindowState: { ID: 0x0016, type: zigbee_herdsman_1.Zcl.DataType.BITMAP8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysOpenWindowSensitivity: { ID: 0x0017, type: zigbee_herdsman_1.Zcl.DataType.UINT16, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysOpenWindowDetectionPeriod: {
ID: 0x0018,
type: zigbee_herdsman_1.Zcl.DataType.UINT16,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
ubisysOpenWindowTimeout: { ID: 0x0019, type: zigbee_herdsman_1.Zcl.DataType.UINT16, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysProportionalGain: { ID: 0x0020, type: zigbee_herdsman_1.Zcl.DataType.INT16, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysProportionalShift: { ID: 0x0021, type: zigbee_herdsman_1.Zcl.DataType.INT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysIntegralFactor: { ID: 0x0022, type: zigbee_herdsman_1.Zcl.DataType.INT16, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
},
commands: {},
commandsResponse: {},
}),
addCustomClusterGenLevelCtrl: () => (0, modernExtend_1.deviceAddCustomCluster)("genLevelCtrl", {
ID: 0x0008,
attributes: {
// D1(-R)
ubisysMinimumOnLevel: { ID: 0x0000, type: zigbee_herdsman_1.Zcl.DataType.UINT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
// H10
ubisysValveType: { ID: 0x0001, type: zigbee_herdsman_1.Zcl.DataType.BITMAP8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysCyclePeriod: { ID: 0x0002, type: zigbee_herdsman_1.Zcl.DataType.UINT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysSeason: { ID: 0x0003, type: zigbee_herdsman_1.Zcl.DataType.ENUM8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysBackupLevel: { ID: 0x0004, type: zigbee_herdsman_1.Zcl.DataType.UINT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysAlternateBackupLevel: { ID: 0x0005, type: zigbee_herdsman_1.Zcl.DataType.UINT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysLowerRange: { ID: 0x0006, type: zigbee_herdsman_1.Zcl.DataType.UINT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysUpperRange: { ID: 0x0007, type: zigbee_herdsman_1.Zcl.DataType.UINT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysPumpThresholdOn: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.UINT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysPumpThresholdOff: { ID: 0x0009, type: zigbee_herdsman_1.Zcl.DataType.UINT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysHeatingDemandEnableThreshold: {
ID: 0x000a,
type: zigbee_herdsman_1.Zcl.DataType.UINT8,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
ubisysHeatingDemandDisableThreshold: {
ID: 0x000b,
type: zigbee_herdsman_1.Zcl.DataType.UINT8,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
ubisysCoolingDemandEnableThreshold: {
ID: 0x000c,
type: zigbee_herdsman_1.Zcl.DataType.UINT8,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
ubisysCoolingDemandDisableThreshold: {
ID: 0x000d,
type: zigbee_herdsman_1.Zcl.DataType.UINT8,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
},
commands: {},
commandsResponse: {},
}),
addCustomClusterClosuresWindowCovering: () => (0, modernExtend_1.deviceAddCustomCluster)("closuresWindowCovering", {
ID: 0x0102,
attributes: {
// J1(-R)
ubisysTurnaroundGuardTime: { ID: 0x1000, type: zigbee_herdsman_1.Zcl.DataType.UINT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysLiftToTiltTransitionSteps: {
ID: 0x1001,
type: zigbee_herdsman_1.Zcl.DataType.UINT16,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
ubisysTotalSteps: { ID: 0x1002, type: zigbee_herdsman_1.Zcl.DataType.UINT16, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysLiftToTiltTransitionSteps2: {
ID: 0x1003,
type: zigbee_herdsman_1.Zcl.DataType.UINT16,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
ubisysTotalSteps2: { ID: 0x1004, type: zigbee_herdsman_1.Zcl.DataType.UINT16, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysAdditionalSteps: { ID: 0x1005, type: zigbee_herdsman_1.Zcl.DataType.UINT8, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
ubisysInactivePowerThreshold: {
ID: 0x1006,
type: zigbee_herdsman_1.Zcl.DataType.UINT16,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
},
ubisysStartupSteps: { ID: 0x1007, type: zigbee_herdsman_1.Zcl.DataType.UINT16, manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH },
},
commands: {},
commandsResponse: {},
}),
addCustomClusterManuSpecificUbisysDeviceSetup: () => (0, modernExtend_1.deviceAddCustomCluster)("manuSpecificUbisysDeviceSetup", {
ID: 0xfc00,
// XXX: once we moved all manuSpecific ones out of zh, we should revisit this
// Doesn't use manufacturerCode: https://github.com/Koenkk/zigbee-herdsman-converters/pull/4412
attributes: {
inputConfigurations: { ID: 0x0000, type: zigbee_herdsman_1.Zcl.DataType.ARRAY },
inputActions: { ID: 0x0001, type: zigbee_herdsman_1.Zcl.DataType.ARRAY },
},
commands: {},
commandsResponse: {},
}),
addCustomClusterManuSpecificUbisysDimmerSetup: () => (0, modernExtend_1.deviceAddCustomCluster)("manuSpecificUbisysDimmerSetup", {
ID: 0xfc01,
manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH,
attributes: {
capabilities: { ID: 0x0000, type: zigbee_herdsman_1.Zcl.DataType.BITMAP8 },
status: { ID: 0x0001, type: zigbee_herdsman_1.Zcl.DataType.BITMAP8 },
mode: { ID: 0x0002, type: zigbee_herdsman_1.Zcl.DataType.BITMAP8 },
},
commands: {},
commandsResponse: {},
}),
localTemperatureOffset: (args) => (0, modernExtend_1.numeric)({
name: "local_temperature_offset",
cluster: "hvacThermostat",
attribute: "ubisysTemperatureOffset",
entityCategory: "config",
description: "Specifies the temperature offset for the locally measured temperature value.",
valueMin: -10,
valueMax: 10,
unit: "ºC",
...args,
}),
occupiedHeatingSetpointDefault: (args) => (0, modernExtend_1.numeric)({
name: "occupied_heating_default_setpoint",
cluster: "hvacThermostat",
attribute: "ubisysDefaultOccupiedHeatingSetpoint",
entityCategory: "config",
description: "Specifies the default heating setpoint during occupancy, " +
"representing the targeted temperature when a recurring weekly schedule ends without a follow-up schedule.",
scale: 100,
valueStep: 0.5, // H1 interface uses 0.5 step
valueMin: 7,
valueMax: 30,
unit: "ºC",
...args,
}),
remoteTemperatureDuration: (args) => (0, modernExtend_1.numeric)({
name: "remote_temperature_duration",
cluster: "hvacThermostat",
attribute: "ubisysRemoteTemperatureValidDuration",
entityCategory: "config",
description: "Specifies the duration period in seconds, during which a remotely measured temperature value " +
"remains valid since its reception as attribute report.",
valueMin: 0,
valueMax: 86400,
unit: "s",
...args,
}),
vacationMode: () => {
const clusterName = "hvacThermostat";
const writeableAttributeName = "ubisysVacationMode";
const readableAttributeName = "occupancy";
const propertyName = "vacation_mode";
const access = exposes_1.access.ALL;
const expose = exposes_1.presets
.binary(propertyName, access, true, false)
.withDescription("When Vacation Mode is active the schedule is disabled and unoccupied_heating_setpoint is used.");
const fromZigbee = [
{
cluster: clusterName,
type: ["attributeReport", "readResponse"],
convert: (model, msg, publish, options, meta) => {
if (msg.data[readableAttributeName] !== undefined) {
return { [propertyName]: msg.data.occupancy === 0 };
}
},
},
];
const toZigbee = [
{
key: [propertyName],
convertSet: async (entity, key, value, meta) => {
if (typeof value === "boolean") {
await entity.write(clusterName, { [writeableAttributeName]: value ? 1 : 0 }, { manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.UBISYS_TECHNOLOGIES_GMBH });
}
else {
logger_1.logger.error(`${propertyName} must be a boolean!`, NS);
}
},
convertGet: async (entity, key, meta) => {
await entity.read(clusterName, [readableAttributeName]);
},
},
];
const configure = [
(0, modernExtend_1.setupConfigureForReporting)(clusterName, readableAttributeName, { config: { min: 0, max: "1_HOUR", change: 0 }, access }),
];
return { exposes: [expose], fromZigbee, toZigbee, configure, isModernExtend: true };
},
openWindowState: (args) => (0, modernExtend_1.binary)({
name: "open_window_state",
cluster: "hvacThermostat",
attribute: "ubisysOpenWindowState",
access: "STATE_GET",
valueOn: [true, 1],
valueOff: [false, 0],
description: "Presents the currently detected window state.",
...args,
}),
openWindowDetect: (args) => (0, modernExtend_1.binary)({
name: "open_window_detect",
cluster: "hvacThermostat",
attribute: "ubisysDetectOpenWindow",
entityCategory: "config",
valueOn: [true, 1],
valueOff: [false, 0],
description: "Specifies whether the Open Window Detection is activated or deactivated.",
...args,
}),
openWindowTimeout: (args) => (0, modernExtend_1.numeric)({
name: "open_window_timeout",
cluster: "hvacThermostat",
attribute: "ubisysOpenWindowTimeout",
entityCategory: "config",
description: "Specifies the maximum time duration in seconds for a detected open-window state. This attribute " +
"effectively defines how long a detected open-window state should last before H1 returns back to " +
"its default set point settings.",
valueMin: 0,
valueMax: 86400,
unit: "s",
...args,
}),
openWindowDetectionPeriod: (args) => (0, modernExtend_1.numeric)({
name: "open_window_detection_periode",
cluster: "hvacThermostat",
attribute: "ubisysOpenWindowDetectionPeriod",
entityCategory: "config",
description: "Specifies the time duration in minutes, within which the sharp temperature change must have taken " +
"place for the open window detection.",
valueMin: 1,
valueMax: 180,
unit: "m",
...args,
}),
openWindowSensitivity: (args) => (0, modernExtend_1.numeric)({
name: "open_window_sensitivity",
cluster: "hvacThermostat",
attribute: "ubisysOpenWindowSensitivity",
entityCategory: "config",
description: "Specifies the temperature change threshold for the Open Window Detection. This is the point at " +
"which the H1 detects a significant temperature change indicating the detection of an open or " +
"closed window.",
scale: 100,
valueStep: 0.5, // H1 interface uses 0.5 step
valueMin: 1,
valueMax: 30,
unit: "ºC",
...args,
}),
};
//# sourceMappingURL=ubisys.js.map