UNPKG

zigbee-herdsman-converters

Version:

Collection of device converters to be used with zigbee-herdsman

123 lines 6.11 kB
"use strict"; var __createBinding = (this && this.__createBinding) || (Object.create ? (function(o, m, k, k2) { if (k2 === undefined) k2 = k; var desc = Object.getOwnPropertyDescriptor(m, k); if (!desc || ("get" in desc ? !m.__esModule : desc.writable || desc.configurable)) { desc = { enumerable: true, get: function() { return m[k]; } }; } Object.defineProperty(o, k2, desc); }) : (function(o, m, k, k2) { if (k2 === undefined) k2 = k; o[k2] = m[k]; })); var __setModuleDefault = (this && this.__setModuleDefault) || (Object.create ? (function(o, v) { Object.defineProperty(o, "default", { enumerable: true, value: v }); }) : function(o, v) { o["default"] = v; }); var __importStar = (this && this.__importStar) || (function () { var ownKeys = function(o) { ownKeys = Object.getOwnPropertyNames || function (o) { var ar = []; for (var k in o) if (Object.prototype.hasOwnProperty.call(o, k)) ar[ar.length] = k; return ar; }; return ownKeys(o); }; return function (mod) { if (mod && mod.__esModule) return mod; var result = {}; if (mod != null) for (var k = ownKeys(mod), i = 0; i < k.length; i++) if (k[i] !== "default") __createBinding(result, mod, k[i]); __setModuleDefault(result, mod); return result; }; })(); Object.defineProperty(exports, "__esModule", { value: true }); exports.definitions = void 0; const exposes = __importStar(require("../lib/exposes")); const m = __importStar(require("../lib/modernExtend")); const tuya = __importStar(require("../lib/tuya")); const e = exposes.presets; const ea = exposes.access; exports.definitions = [ { fingerprint: tuya.fingerprint("TS0601", ["_TZE204_e5hpkc6d", "_TZE200_4hbx5cvx", "_TZE200_e5hpkc6d"]), model: "TS0601_futurehome_thermostat", vendor: "Futurehome", description: "Thermostat", fromZigbee: [tuya.fz.datapoints], toZigbee: [tuya.tz.datapoints], whiteLabel: [tuya.whitelabel("Futurehome", "Co020", "Smart thermostat", ["_TZE200_e5hpkc6d"])], onEvent: tuya.onEventSetTime, configure: tuya.configureMagicPacket, exposes: [ e .climate() .withSystemMode(["off", "heat"], ea.STATE_SET, "Whether the thermostat is turned on or off") .withPreset(["user", "home", "away", "auto"]) .withLocalTemperature(ea.STATE) .withLocalTemperatureCalibration(-9, 9, 1, ea.STATE_SET) .withRunningState(["idle", "heat"], ea.STATE) .withSetpoint("current_heating_setpoint", 5, 35, 1, ea.STATE_SET), e .temperature_sensor_select(["air_sensor", "floor_sensor", "max_guard"]) .withDescription("Max guard. Floor sensor must be installed. The thermostat will regulate according to the room sensor, " + "but interrupt heating if the floor sensor exceeds the maximum guard temperature. Standard is 27°C" + "\n\n" + "There is also a maximum guard when the thermostat is set to floor sensor. " + "The thermostat regulates according to the floor sensor, but will interrupt heating if the floor sensor " + "exceeds the maximum guard temperature. Standard is 27°C."), e .numeric("local_temperature_floor", ea.STATE) .withUnit("°C") .withDescription("Current temperature measured on the external sensor (floor)") .withValueStep(1), e.child_lock(), e.window_detection(), e .numeric("hysteresis", ea.STATE_SET) .withUnit("°C") .withDescription("The offset from the target temperature in which the temperature has to " + "change for the heating state to change. This is to prevent erratically turning on/off " + "when the temperature is close to the target.") .withValueMin(1) .withValueMax(9) .withValueStep(1), e .numeric("max_temperature_protection", ea.STATE_SET) .withUnit("°C") .withDescription("Max guarding temperature") .withValueMin(20) .withValueMax(95) .withValueStep(1), ], meta: { tuyaDatapoints: [ [1, "system_mode", tuya.valueConverterBasic.lookup({ off: false, heat: true })], [2, "preset", tuya.valueConverterBasic.lookup({ user: tuya.enum(0), home: tuya.enum(1), away: tuya.enum(2), auto: tuya.enum(3) })], [16, "current_heating_setpoint", tuya.valueConverter.raw], [24, "local_temperature", tuya.valueConverter.raw], [28, "local_temperature_calibration", tuya.valueConverter.raw], [30, "child_lock", tuya.valueConverter.lockUnlock], [101, "local_temperature_floor", tuya.valueConverter.raw], [102, "sensor", tuya.valueConverterBasic.lookup({ air_sensor: tuya.enum(0), floor_sensor: tuya.enum(1), max_guard: tuya.enum(2) })], [103, "hysteresis", tuya.valueConverter.raw], [104, "running_state", tuya.valueConverterBasic.lookup({ idle: false, heat: true })], // In the old handler, endpoint 105 was left unused. I don't know what this value means. // Leaving it in here for future reference in case someone else figures it out. // connecteTempProgram: 105 [106, "window_detection", tuya.valueConverter.onOff], [107, "max_temperature_protection", tuya.valueConverter.raw], ], }, }, { zigbeeModel: ["FH9130"], model: "4509243", vendor: "Futurehome", description: "Smart puck", ota: true, extend: [m.light({ configureReporting: true })], }, ]; //# sourceMappingURL=futurehome.js.map