zigbee-herdsman-converters
Version:
Collection of device converters to be used with zigbee-herdsman
123 lines • 6.11 kB
JavaScript
var __createBinding = (this && this.__createBinding) || (Object.create ? (function(o, m, k, k2) {
if (k2 === undefined) k2 = k;
var desc = Object.getOwnPropertyDescriptor(m, k);
if (!desc || ("get" in desc ? !m.__esModule : desc.writable || desc.configurable)) {
desc = { enumerable: true, get: function() { return m[k]; } };
}
Object.defineProperty(o, k2, desc);
}) : (function(o, m, k, k2) {
if (k2 === undefined) k2 = k;
o[k2] = m[k];
}));
var __setModuleDefault = (this && this.__setModuleDefault) || (Object.create ? (function(o, v) {
Object.defineProperty(o, "default", { enumerable: true, value: v });
}) : function(o, v) {
o["default"] = v;
});
var __importStar = (this && this.__importStar) || (function () {
var ownKeys = function(o) {
ownKeys = Object.getOwnPropertyNames || function (o) {
var ar = [];
for (var k in o) if (Object.prototype.hasOwnProperty.call(o, k)) ar[ar.length] = k;
return ar;
};
return ownKeys(o);
};
return function (mod) {
if (mod && mod.__esModule) return mod;
var result = {};
if (mod != null) for (var k = ownKeys(mod), i = 0; i < k.length; i++) if (k[i] !== "default") __createBinding(result, mod, k[i]);
__setModuleDefault(result, mod);
return result;
};
})();
Object.defineProperty(exports, "__esModule", { value: true });
exports.definitions = void 0;
const exposes = __importStar(require("../lib/exposes"));
const m = __importStar(require("../lib/modernExtend"));
const tuya = __importStar(require("../lib/tuya"));
const e = exposes.presets;
const ea = exposes.access;
exports.definitions = [
{
fingerprint: tuya.fingerprint("TS0601", ["_TZE204_e5hpkc6d", "_TZE200_4hbx5cvx", "_TZE200_e5hpkc6d"]),
model: "TS0601_futurehome_thermostat",
vendor: "Futurehome",
description: "Thermostat",
fromZigbee: [tuya.fz.datapoints],
toZigbee: [tuya.tz.datapoints],
whiteLabel: [tuya.whitelabel("Futurehome", "Co020", "Smart thermostat", ["_TZE200_e5hpkc6d"])],
onEvent: tuya.onEventSetTime,
configure: tuya.configureMagicPacket,
exposes: [
e
.climate()
.withSystemMode(["off", "heat"], ea.STATE_SET, "Whether the thermostat is turned on or off")
.withPreset(["user", "home", "away", "auto"])
.withLocalTemperature(ea.STATE)
.withLocalTemperatureCalibration(-9, 9, 1, ea.STATE_SET)
.withRunningState(["idle", "heat"], ea.STATE)
.withSetpoint("current_heating_setpoint", 5, 35, 1, ea.STATE_SET),
e
.temperature_sensor_select(["air_sensor", "floor_sensor", "max_guard"])
.withDescription("Max guard. Floor sensor must be installed. The thermostat will regulate according to the room sensor, " +
"but interrupt heating if the floor sensor exceeds the maximum guard temperature. Standard is 27°C" +
"\n\n" +
"There is also a maximum guard when the thermostat is set to floor sensor. " +
"The thermostat regulates according to the floor sensor, but will interrupt heating if the floor sensor " +
"exceeds the maximum guard temperature. Standard is 27°C."),
e
.numeric("local_temperature_floor", ea.STATE)
.withUnit("°C")
.withDescription("Current temperature measured on the external sensor (floor)")
.withValueStep(1),
e.child_lock(),
e.window_detection(),
e
.numeric("hysteresis", ea.STATE_SET)
.withUnit("°C")
.withDescription("The offset from the target temperature in which the temperature has to " +
"change for the heating state to change. This is to prevent erratically turning on/off " +
"when the temperature is close to the target.")
.withValueMin(1)
.withValueMax(9)
.withValueStep(1),
e
.numeric("max_temperature_protection", ea.STATE_SET)
.withUnit("°C")
.withDescription("Max guarding temperature")
.withValueMin(20)
.withValueMax(95)
.withValueStep(1),
],
meta: {
tuyaDatapoints: [
[1, "system_mode", tuya.valueConverterBasic.lookup({ off: false, heat: true })],
[2, "preset", tuya.valueConverterBasic.lookup({ user: tuya.enum(0), home: tuya.enum(1), away: tuya.enum(2), auto: tuya.enum(3) })],
[16, "current_heating_setpoint", tuya.valueConverter.raw],
[24, "local_temperature", tuya.valueConverter.raw],
[28, "local_temperature_calibration", tuya.valueConverter.raw],
[30, "child_lock", tuya.valueConverter.lockUnlock],
[101, "local_temperature_floor", tuya.valueConverter.raw],
[102, "sensor", tuya.valueConverterBasic.lookup({ air_sensor: tuya.enum(0), floor_sensor: tuya.enum(1), max_guard: tuya.enum(2) })],
[103, "hysteresis", tuya.valueConverter.raw],
[104, "running_state", tuya.valueConverterBasic.lookup({ idle: false, heat: true })],
// In the old handler, endpoint 105 was left unused. I don't know what this value means.
// Leaving it in here for future reference in case someone else figures it out.
// connecteTempProgram: 105
[106, "window_detection", tuya.valueConverter.onOff],
[107, "max_temperature_protection", tuya.valueConverter.raw],
],
},
},
{
zigbeeModel: ["FH9130"],
model: "4509243",
vendor: "Futurehome",
description: "Smart puck",
ota: true,
extend: [m.light({ configureReporting: true })],
},
];