zigbee-herdsman-converters
Version:
Collection of device converters to be used with zigbee-herdsman
177 lines • 7.24 kB
JavaScript
var __createBinding = (this && this.__createBinding) || (Object.create ? (function(o, m, k, k2) {
if (k2 === undefined) k2 = k;
var desc = Object.getOwnPropertyDescriptor(m, k);
if (!desc || ("get" in desc ? !m.__esModule : desc.writable || desc.configurable)) {
desc = { enumerable: true, get: function() { return m[k]; } };
}
Object.defineProperty(o, k2, desc);
}) : (function(o, m, k, k2) {
if (k2 === undefined) k2 = k;
o[k2] = m[k];
}));
var __setModuleDefault = (this && this.__setModuleDefault) || (Object.create ? (function(o, v) {
Object.defineProperty(o, "default", { enumerable: true, value: v });
}) : function(o, v) {
o["default"] = v;
});
var __importStar = (this && this.__importStar) || (function () {
var ownKeys = function(o) {
ownKeys = Object.getOwnPropertyNames || function (o) {
var ar = [];
for (var k in o) if (Object.prototype.hasOwnProperty.call(o, k)) ar[ar.length] = k;
return ar;
};
return ownKeys(o);
};
return function (mod) {
if (mod && mod.__esModule) return mod;
var result = {};
if (mod != null) for (var k = ownKeys(mod), i = 0; i < k.length; i++) if (k[i] !== "default") __createBinding(result, mod, k[i]);
__setModuleDefault(result, mod);
return result;
};
})();
Object.defineProperty(exports, "__esModule", { value: true });
exports.definitions = void 0;
const fz = __importStar(require("../converters/fromZigbee"));
const tz = __importStar(require("../converters/toZigbee"));
const exposes = __importStar(require("../lib/exposes"));
const m = __importStar(require("../lib/modernExtend"));
const reporting = __importStar(require("../lib/reporting"));
const e = exposes.presets;
const ea = exposes.access;
exports.definitions = [
{
zigbeeModel: ["PSS_00.00.00.15TC"],
model: "PSS-23ZBS",
vendor: "Climax",
description: "Power plug",
extend: [m.onOff()],
},
{
zigbeeModel: ["SD8SC_00.00.03.12TC"],
model: "SD-8SCZBS",
vendor: "Climax",
description: "Smoke detector",
fromZigbee: [fz.ias_smoke_alarm_1, fz.battery],
toZigbee: [tz.warning],
exposes: [e.smoke(), e.battery(), e.battery_low(), e.tamper(), e.warning()],
},
{
zigbeeModel: ["WS15_00.00.00.10TC"],
model: "WLS-15ZBS",
vendor: "Climax",
description: "Water leakage sensor",
fromZigbee: [fz.ias_water_leak_alarm_1, fz.battery],
toZigbee: [],
exposes: [e.water_leak(), e.battery_low(), e.tamper(), e.battery()],
},
{
zigbeeModel: ["SCM-3_00.00.03.15"],
model: "SCM-5ZBS",
vendor: "Climax",
description: "Roller shutter",
fromZigbee: [fz.cover_position_via_brightness, fz.cover_state_via_onoff],
toZigbee: [tz.cover_via_brightness],
exposes: [e.cover_position().setAccess("state", ea.ALL)],
},
{
zigbeeModel: [
"PSM_00.00.00.35TC",
"PSMP5_00.00.02.02TC",
"PSMP5_00.00.05.01TC",
"PSMP5_00.00.05.10TC",
"PSMP5_00.00.03.15TC",
"PSMP5_00.00.03.16TC",
"PSMP5_00.00.03.19TC",
],
model: "PSM-29ZBSR",
vendor: "Climax",
description: "Power plug",
fromZigbee: [fz.on_off, fz.metering, fz.ignore_basic_report],
toZigbee: [tz.on_off, tz.ignore_transition],
configure: async (device, coordinatorEndpoint) => {
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ["genOnOff", "seMetering"]);
await reporting.onOff(endpoint);
await reporting.readMeteringMultiplierDivisor(endpoint);
await reporting.instantaneousDemand(endpoint, { min: 10, change: 2 });
},
whiteLabel: [{ vendor: "Blaupunkt", model: "PSM-S1" }],
exposes: [e.switch(), e.power(), e.energy()],
},
{
zigbeeModel: ["RS_00.00.02.06TC"],
model: "RS-23ZBS",
vendor: "Climax",
description: "Temperature & humidity sensor",
fromZigbee: [fz.temperature, fz.humidity],
toZigbee: [],
configure: async (device, coordinatorEndpoint) => {
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ["msTemperatureMeasurement", "msRelativeHumidity"]);
await reporting.temperature(endpoint);
// configureReporting.humidity(endpoint); not needed and fails
// https://github.com/Koenkk/zigbee-herdsman-converters/issues/1312
},
exposes: [e.temperature(), e.humidity()],
},
{
zigbeeModel: ["SRACBP5_00.00.03.06TC", "SRAC_00.00.00.16TC", "SRACBP5_00.00.05.10TC"],
model: "SRAC-23B-ZBSR",
vendor: "Climax",
description: "Smart siren",
fromZigbee: [fz.battery, fz.ias_wd, fz.ias_enroll, fz.ias_siren],
toZigbee: [tz.warning_simple, tz.ias_max_duration, tz.warning, tz.squawk],
configure: async (device, coordinatorEndpoint) => {
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ["genBasic", "ssIasZone", "ssIasWd"]);
await endpoint.read("ssIasZone", ["zoneState", "iasCieAddr", "zoneId"]);
await endpoint.read("ssIasWd", ["maxDuration"]);
},
exposes: [
e.battery_low(),
e.tamper(),
e.warning(),
e.squawk(),
e.numeric("max_duration", ea.ALL).withUnit("s").withValueMin(0).withValueMax(600).withDescription("Duration of Siren"),
e.binary("alarm", ea.SET, "START", "OFF").withDescription("Manual start of siren"),
],
},
{
zigbeeModel: ["WS15_00.00.00.14TC"],
model: "WS-15ZBS",
vendor: "Climax",
description: "Water leak sensor",
fromZigbee: [fz.ias_water_leak_alarm_1],
toZigbee: [],
exposes: [e.water_leak(), e.battery_low(), e.tamper()],
},
{
zigbeeModel: ["CO_00.00.00.15TC", "CO_00.00.00.22TC"],
model: "CO-8ZBS",
vendor: "Climax",
description: "Smart carbon monoxide sensor",
fromZigbee: [fz.ias_carbon_monoxide_alarm_1, fz.battery],
toZigbee: [],
exposes: [e.carbon_monoxide(), e.battery_low(), e.tamper(), e.battery()],
},
{
zigbeeModel: ["KP-ACE_00.00.03.12TC", "KP-ACE_00.00.03.11TC"],
model: "KP-23EL-ZBS-ACE",
vendor: "Climax",
description: "Remote Keypad",
fromZigbee: [fz.ias_keypad, fz.battery, fz.command_arm, fz.command_panic, fz.command_emergency],
toZigbee: [],
exposes: [e.battery_low(), e.tamper(), e.action(["emergency", "panic", "disarm", "arm_all_zones", "arm_day_zones"])],
},
{
zigbeeModel: ["PRL_00.00.03.04TC"],
model: "PRL-1ZBS-12/24V",
vendor: "Climax",
description: "Zigbee 12-24V relay controller",
extend: [m.identify(), m.onOff(), m.forcePowerSource({ powerSource: "Mains (single phase)" })],
},
];