UNPKG

zigbee-herdsman-converters

Version:

Collection of device converters to be used with zigbee-herdsman

687 lines • 38.2 kB
"use strict"; var __createBinding = (this && this.__createBinding) || (Object.create ? (function(o, m, k, k2) { if (k2 === undefined) k2 = k; var desc = Object.getOwnPropertyDescriptor(m, k); if (!desc || ("get" in desc ? !m.__esModule : desc.writable || desc.configurable)) { desc = { enumerable: true, get: function() { return m[k]; } }; } Object.defineProperty(o, k2, desc); }) : (function(o, m, k, k2) { if (k2 === undefined) k2 = k; o[k2] = m[k]; })); var __setModuleDefault = (this && this.__setModuleDefault) || (Object.create ? (function(o, v) { Object.defineProperty(o, "default", { enumerable: true, value: v }); }) : function(o, v) { o["default"] = v; }); var __importStar = (this && this.__importStar) || function (mod) { if (mod && mod.__esModule) return mod; var result = {}; if (mod != null) for (var k in mod) if (k !== "default" && Object.prototype.hasOwnProperty.call(mod, k)) __createBinding(result, mod, k); __setModuleDefault(result, mod); return result; }; var __importDefault = (this && this.__importDefault) || function (mod) { return (mod && mod.__esModule) ? mod : { "default": mod }; }; Object.defineProperty(exports, "__esModule", { value: true }); const exposes = __importStar(require("../lib/exposes")); const fromZigbee_1 = __importDefault(require("../converters/fromZigbee")); const legacy = __importStar(require("../lib/legacy")); const toZigbee_1 = __importDefault(require("../converters/toZigbee")); const reporting = __importStar(require("../lib/reporting")); const ota = __importStar(require("../lib/ota")); const legrand_1 = require("../lib/legrand"); const modernExtend_1 = require("../lib/modernExtend"); const e = exposes.presets; const ea = exposes.access; const definitions = [ { zigbeeModel: [' Pocket remote\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000', ' Wireless Scenes Command\u0000\u0000\u0000\u0000\u0000\u0000\u0000'], model: '067755', vendor: 'Legrand', description: 'Wireless and batteryless 4 scenes control', ota: ota.zigbeeOTA, meta: { multiEndpoint: true, battery: { voltageToPercentage: '3V_2500' }, publishDuplicateTransaction: true }, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.battery, fromZigbee_1.default.command_recall], toZigbee: [], exposes: [e.battery(), e.action(['identify', 'recall_1_1'])], onEvent: legrand_1.readInitialBatteryState, configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg', 'genOnOff', 'genLevelCtrl']); }, }, { zigbeeModel: [' Dry contact\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000' + '\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000'], model: '412173', vendor: 'Legrand', description: 'DIN dry contactor module', whiteLabel: [{ vendor: 'BTicino', model: 'FC80AC' }], extend: [(0, modernExtend_1.onOff)()], ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.electrical_measurement, legrand_1.fzLegrand.cluster_fc01, fromZigbee_1.default.ignore_basic_report, fromZigbee_1.default.ignore_genOta], toZigbee: [toZigbee_1.default.legrand_device_mode, legrand_1.tzLegrand.identify, toZigbee_1.default.electrical_measurement_power], exposes: [ e.power().withAccess(ea.STATE_GET), e.enum('device_mode', ea.ALL, ['switch', 'auto']) .withDescription('switch: allow on/off, auto will use wired action via C1/C2 on contactor for example with HC/HP'), ], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genIdentify', 'genOnOff', 'haElectricalMeasurement']); await reporting.onOff(endpoint); await reporting.readEletricalMeasurementMultiplierDivisors(endpoint); await reporting.activePower(endpoint); // Read configuration values that are not sent periodically as well as current power (activePower). await endpoint.read('haElectricalMeasurement', ['activePower', 0xf000, 0xf001, 0xf002]); }, }, { zigbeeModel: [' Contactor\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000' + '\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000'], model: '412171', vendor: 'Legrand', description: 'DIN contactor module', whiteLabel: [{ vendor: 'BTicino', model: 'FC80CC' }], extend: [(0, modernExtend_1.onOff)(), (0, modernExtend_1.electricityMeter)({ cluster: 'electrical' })], ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, legrand_1.fzLegrand.cluster_fc01, fromZigbee_1.default.ignore_basic_report, fromZigbee_1.default.ignore_genOta], toZigbee: [toZigbee_1.default.legrand_device_mode, legrand_1.tzLegrand.identify, legrand_1.tzLegrand.auto_mode], exposes: [ e.enum('device_mode', ea.ALL, ['switch', 'auto']) .withDescription('Switch: allow manual on/off, auto uses contact\'s C1/C2 wired actions for Peak/Off-Peak electricity rates'), e.enum('auto_mode', ea.STATE_SET, ['off', 'auto', 'on_override']) .withDescription('Off/auto/on (override) (works only if device is set to "auto" mode)'), ], }, { zigbeeModel: [' Teleruptor\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000' + '\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000'], model: '412170', vendor: 'Legrand', description: 'DIN smart relay for light control', whiteLabel: [{ vendor: 'BTicino', model: 'FC80RC' }], extend: [(0, modernExtend_1.onOff)()], ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.electrical_measurement, legrand_1.fzLegrand.cluster_fc01, fromZigbee_1.default.ignore_basic_report, fromZigbee_1.default.ignore_genOta], toZigbee: [toZigbee_1.default.legrand_device_mode, legrand_1.tzLegrand.identify, toZigbee_1.default.electrical_measurement_power], exposes: [ e.power().withAccess(ea.STATE_GET), e.enum('device_mode', ea.ALL, ['switch', 'auto']) .withDescription('switch: allow on/off, auto will use wired action via C1/C2 on teleruptor with buttons'), ], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genIdentify', 'haElectricalMeasurement']); await reporting.readEletricalMeasurementMultiplierDivisors(endpoint); await reporting.activePower(endpoint); }, }, { zigbeeModel: [' Shutters central remote switch'], model: '067646', vendor: 'Legrand', description: 'Wireless shutter switch', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.ignore_basic_report, fromZigbee_1.default.command_cover_open, fromZigbee_1.default.command_cover_close, fromZigbee_1.default.command_cover_stop, fromZigbee_1.default.battery, fromZigbee_1.default.legrand_binary_input_moving], toZigbee: [], exposes: [e.battery(), e.action(['identify', 'open', 'close', 'stop', 'moving', 'stopped'])], onEvent: async (type, data, device, options, state) => { await (0, legrand_1.readInitialBatteryState)(type, data, device, options, state); if (data.type === 'commandCheckin' && data.cluster === 'genPollCtrl') { const endpoint = device.getEndpoint(1); await endpoint.command('genPollCtrl', 'fastPollStop', {}, legrand_1.legrandOptions); } }, configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg', 'genBinaryInput', 'closuresWindowCovering', 'genIdentify']); }, }, { zigbeeModel: [' Shutter switch with neutral\u0000\u0000\u0000'], model: '067776', vendor: 'Legrand', description: 'Netatmo wired shutter switch', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.ignore_basic_report, fromZigbee_1.default.cover_position_tilt, fromZigbee_1.default.legrand_binary_input_moving, fromZigbee_1.default.identify, legrand_1.fzLegrand.cluster_fc01, legrand_1.fzLegrand.calibration_mode(false)], toZigbee: [toZigbee_1.default.cover_state, toZigbee_1.default.cover_position_tilt, legrand_1.tzLegrand.identify, legrand_1.tzLegrand.led_mode, legrand_1.tzLegrand.calibration_mode(false)], exposes: (device, options) => { return [ legrand_1._067776.getCover(device), e.action(['moving', 'identify']), legrand_1.eLegrand.identify(), legrand_1.eLegrand.ledInDark(), legrand_1.eLegrand.ledIfOn(), legrand_1._067776.getCalibrationModes(false), e.linkquality(), ]; }, configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genBinaryInput', 'closuresWindowCovering', 'genIdentify']); let p = reporting.payload('currentPositionLiftPercentage', 1, 120, 1); await endpoint.configureReporting('closuresWindowCovering', p, legrand_1.legrandOptions); p = reporting.payload('currentPositionTiltPercentage', 1, 120, 1); await endpoint.configureReporting('closuresWindowCovering', p, legrand_1.legrandOptions); }, }, { // Some require coverInverted: // - https://github.com/Koenkk/zigbee2mqtt/issues/15101#issuecomment-1356787490 // - https://github.com/Koenkk/zigbee2mqtt/issues/16090 fingerprint: [ { modelID: ' Shutter switch with neutral\u0000\u0000\u0000', softwareBuildID: '001a' }, { modelID: ' Shutter switch with neutral\u0000\u0000\u0000', softwareBuildID: '00d\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u00000\u0012\u0002\u0000' + '\t\u0007\u0000\u0018\u0002\u0003\b\u0000 \u00132\u0000\u0000\u0000\u0000X\u0002\n\u0000\u0000\u0000\u0000d' + '\u0017\u0000\u0018\u0000' }, ], model: '067776_inverted', vendor: 'Legrand', description: 'Netatmo wired shutter switch', ota: ota.zigbeeOTA, meta: { coverInverted: true }, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.ignore_basic_report, fromZigbee_1.default.legrand_binary_input_moving, fromZigbee_1.default.cover_position_tilt, legrand_1.fzLegrand.cluster_fc01], toZigbee: [toZigbee_1.default.cover_state, toZigbee_1.default.cover_position_tilt, legrand_1.tzLegrand.identify, legrand_1.tzLegrand.led_mode], exposes: [e.cover_position()], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genBinaryInput', 'closuresWindowCovering', 'genIdentify']); await reporting.currentPositionLiftPercentage(endpoint); }, }, { zigbeeModel: [' Shutter SW with level control\u0000'], model: '067776A', vendor: 'Legrand', description: 'Netatmo wired shutter switch with level control (NLLV)', whiteLabel: [ { model: 'K4027C/L4027C/N4027C/NT4027C', vendor: 'BTicino', description: 'Shutter SW with level control', fingerprint: [{ hardwareVersion: 9 }, { hardwareVersion: 13 }], }, ], ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.ignore_basic_report, fromZigbee_1.default.cover_position_tilt, fromZigbee_1.default.legrand_binary_input_moving, fromZigbee_1.default.identify, legrand_1.fzLegrand.cluster_fc01, legrand_1.fzLegrand.calibration_mode(true)], toZigbee: [toZigbee_1.default.cover_state, toZigbee_1.default.cover_position_tilt, legrand_1.tzLegrand.identify, legrand_1.tzLegrand.led_mode, legrand_1.tzLegrand.calibration_mode(true)], exposes: (device, options) => { return [ legrand_1._067776.getCover(device), e.action(['moving', 'identify']), legrand_1.eLegrand.identify(), legrand_1.eLegrand.ledInDark(), legrand_1.eLegrand.ledIfOn(), legrand_1._067776.getCalibrationModes(true), e.linkquality(), ]; }, configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genBinaryInput', 'closuresWindowCovering', 'genIdentify']); let p = reporting.payload('currentPositionLiftPercentage', 1, 120, 1); await endpoint.configureReporting('closuresWindowCovering', p, legrand_1.legrandOptions); p = reporting.payload('currentPositionTiltPercentage', 1, 120, 1); await endpoint.configureReporting('closuresWindowCovering', p, legrand_1.legrandOptions); }, }, { // LED blinks RED when battery is low zigbeeModel: [' Remote switch\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000'], model: '067773', vendor: 'Legrand', description: 'Wireless remote switch', ota: ota.zigbeeOTA, meta: { battery: { voltageToPercentage: '3V_2500' }, publishDuplicateTransaction: true }, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.command_on, fromZigbee_1.default.command_off, fromZigbee_1.default.command_toggle, legacy.fz.cmd_move, legacy.fz.cmd_stop, fromZigbee_1.default.battery], toZigbee: [], exposes: [ e.battery(), e.action(['identify', 'on', 'off', 'toggle', 'brightness_move_up', 'brightness_move_down', 'brightness_stop']), ], onEvent: legrand_1.readInitialBatteryState, configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg', 'genOnOff', 'genLevelCtrl']); }, }, { zigbeeModel: [' Double gangs remote switch\u0000\u0000\u0000\u0000'], model: '067774', vendor: 'Legrand', description: 'Wireless double remote switch', ota: ota.zigbeeOTA, meta: { multiEndpoint: true, battery: { voltageToPercentage: '3V_2500' }, publishDuplicateTransaction: true }, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.command_on, fromZigbee_1.default.command_off, fromZigbee_1.default.command_toggle, fromZigbee_1.default.command_move, fromZigbee_1.default.command_stop, fromZigbee_1.default.battery], toZigbee: [], exposes: [ e.battery(), e.action(['identify', 'on', 'off', 'toggle', 'brightness_move_up', 'brightness_move_down', 'brightness_stop']), ], onEvent: legrand_1.readInitialBatteryState, configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg', 'genOnOff', 'genLevelCtrl']); const endpoint2 = device.getEndpoint(2); await reporting.bind(endpoint2, coordinatorEndpoint, ['genOnOff', 'genLevelCtrl']); }, endpoint: (device) => { return { left: 1, right: 2 }; }, }, { zigbeeModel: [' Remote toggle switch\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000'], model: '067694', vendor: 'Legrand', description: 'Remote toggle switch', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.command_on, fromZigbee_1.default.command_off, fromZigbee_1.default.command_toggle, fromZigbee_1.default.battery], toZigbee: [], exposes: [ e.battery(), e.action(['identify', 'on', 'off', 'toggle']), ], onEvent: legrand_1.readInitialBatteryState, configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg', 'genOnOff']); }, }, { zigbeeModel: [' Dimmer switch w/o neutral\u0000\u0000\u0000\u0000\u0000'], model: '067771', vendor: 'Legrand', description: 'Wired switch without neutral', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.lighting_ballast_configuration, legrand_1.fzLegrand.cluster_fc01], toZigbee: [legrand_1.tzLegrand.led_mode, toZigbee_1.default.legrand_device_mode, legrand_1.tzLegrand.identify, toZigbee_1.default.ballast_config], exposes: [ e.numeric('ballast_minimum_level', ea.ALL).withValueMin(1).withValueMax(254) .withDescription('Specifies the minimum brightness value'), e.numeric('ballast_maximum_level', ea.ALL).withValueMin(1).withValueMax(254) .withDescription('Specifies the maximum brightness value'), e.binary('device_mode', ea.ALL, 'dimmer_on', 'dimmer_off') .withDescription('Allow the device to change brightness'), legrand_1.eLegrand.ledInDark(), legrand_1.eLegrand.ledIfOn(), ], extend: [(0, modernExtend_1.light)({ configureReporting: true })], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genIdentify', 'genBinaryInput', 'lightingBallastCfg']); }, }, { zigbeeModel: [' Dimmer switch w/o neutral evo\u0000'], model: '199182', vendor: 'Legrand', description: 'Wired switch without neutral', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.lighting_ballast_configuration, legrand_1.fzLegrand.cluster_fc01], toZigbee: [legrand_1.tzLegrand.led_mode, toZigbee_1.default.legrand_device_mode, legrand_1.tzLegrand.identify, toZigbee_1.default.ballast_config], exposes: [ e.numeric('ballast_minimum_level', ea.ALL).withValueMin(1).withValueMax(254) .withDescription('Specifies the minimum brightness value'), e.numeric('ballast_maximum_level', ea.ALL).withValueMin(1).withValueMax(254) .withDescription('Specifies the maximum brightness value'), e.binary('device_mode', ea.ALL, 'dimmer_on', 'dimmer_off') .withDescription('Allow the device to change brightness'), legrand_1.eLegrand.ledInDark(), legrand_1.eLegrand.ledIfOn(), ], extend: [(0, modernExtend_1.light)({ configureReporting: true })], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genIdentify', 'genBinaryInput', 'lightingBallastCfg']); }, }, { zigbeeModel: [' Connected outlet\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000'], model: '067775/741811', vendor: 'Legrand', description: 'Power socket with power consumption monitoring', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.on_off, fromZigbee_1.default.electrical_measurement, fromZigbee_1.default.power_on_behavior, legrand_1.fzLegrand.cluster_fc01], toZigbee: [toZigbee_1.default.on_off, legrand_1.tzLegrand.led_mode, legrand_1.tzLegrand.identify, toZigbee_1.default.power_on_behavior], exposes: [ e.switch(), e.action(['identify']), e.power(), e.power_apparent(), e.power_on_behavior(), legrand_1.eLegrand.identify(), legrand_1.eLegrand.ledInDark(), legrand_1.eLegrand.ledIfOn(), ], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genIdentify', 'genOnOff', 'haElectricalMeasurement']); await reporting.onOff(endpoint); await reporting.readEletricalMeasurementMultiplierDivisors(endpoint); await reporting.activePower(endpoint); try { await reporting.apparentPower(endpoint); } catch (e) { // Some version/firmware don't seem to support this. // https://github.com/Koenkk/zigbee2mqtt/issues/16732 } }, }, { zigbeeModel: [' Micromodule switch\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000'], model: '064888', vendor: 'Legrand', description: 'Wired micromodule switch', whiteLabel: [{ vendor: 'BTicino', model: '3584C' }], extend: [(0, modernExtend_1.onOff)()], ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify], toZigbee: [legrand_1.tzLegrand.identify], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genBinaryInput']); }, }, { // LED blinks RED when battery is low zigbeeModel: [' Master remote SW Home / Away\u0000\u0000'], model: '064873', vendor: 'Legrand', description: 'Home & away switch / master switch', whiteLabel: [{ vendor: 'BTicino', model: 'LN4570CWI' }], ota: ota.zigbeeOTA, meta: { battery: { voltageToPercentage: '3V_2500' } }, fromZigbee: [fromZigbee_1.default.legrand_scenes, fromZigbee_1.default.legrand_master_switch_center, fromZigbee_1.default.ignore_poll_ctrl, fromZigbee_1.default.battery], toZigbee: [], exposes: [ e.battery(), e.action(['enter', 'leave', 'sleep', 'wakeup', 'center']), ], onEvent: async (type, data, device, options, state) => { await (0, legrand_1.readInitialBatteryState)(type, data, device, options, state); if (data.type === 'commandCheckin' && data.cluster === 'genPollCtrl') { // TODO current solution is a work around, it would be cleaner to answer to the request const endpoint = device.getEndpoint(1); await endpoint.command('genPollCtrl', 'fastPollStop', {}, legrand_1.legrandOptions); } }, configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genIdentify', 'genPowerCfg']); }, }, { zigbeeModel: [' DIN power consumption module\u0000\u0000', ' DIN power consumption module', 'Smart shedder module'], model: '412015', vendor: 'Legrand', description: 'DIN power consumption module', whiteLabel: [ { vendor: 'Legrand', description: 'DIN power consumption module', model: '412172', fingerprint: [{ modelID: ' Smart shedder module' }] }, { vendor: 'BTicino', description: 'DIN power consumption module', model: 'FC80GCS', fingerprint: [{ modelID: ' Smart shedder module' }] }, ], ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.metering, fromZigbee_1.default.electrical_measurement, fromZigbee_1.default.ignore_basic_report, fromZigbee_1.default.ignore_genOta, fromZigbee_1.default.legrand_power_alarm, legrand_1.fzLegrand.cluster_fc01], toZigbee: [legrand_1.tzLegrand.led_mode, legrand_1.tzLegrand.identify, toZigbee_1.default.electrical_measurement_power, toZigbee_1.default.legrand_power_alarm], exposes: [ e.power().withAccess(ea.STATE_GET), e.power_apparent(), e.binary('power_alarm_active', ea.STATE, true, false), e.binary('power_alarm', ea.ALL, true, false).withDescription('Enable/disable the power alarm'), ], onEvent: async (type, data, device, options, state) => { /** * The DIN power consumption module loses the configure reporting * after device restart/powerloss. * * We reconfigure the reporting at deviceAnnounce. */ if (type === 'deviceAnnounce') { for (const endpoint of device.endpoints) { for (const c of endpoint.configuredReportings) { await endpoint.configureReporting(c.cluster.name, [{ attribute: c.attribute.name, minimumReportInterval: c.minimumReportInterval, maximumReportInterval: c.maximumReportInterval, reportableChange: c.reportableChange, }]); } } } }, configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['haElectricalMeasurement', 'genIdentify']); await reporting.readEletricalMeasurementMultiplierDivisors(endpoint); await reporting.activePower(endpoint); await endpoint.read('haElectricalMeasurement', ['activePower']); try { await reporting.apparentPower(endpoint); await endpoint.read('haElectricalMeasurement', ['apparentPower']); } catch (e) { // Some version/firmware don't seem to support this. } // Read configuration values that are not sent periodically. await endpoint.read('haElectricalMeasurement', [0xf000, 0xf001, 0xf002]); }, }, { zigbeeModel: ['Remote switch Wake up / Sleep'], model: '752189', vendor: 'Legrand', description: 'Night/day wireless switch', ota: ota.zigbeeOTA, meta: { battery: { voltageToPercentage: '3V_2500' } }, fromZigbee: [fromZigbee_1.default.legrand_scenes, fromZigbee_1.default.battery, fromZigbee_1.default.ignore_poll_ctrl, fromZigbee_1.default.legrand_master_switch_center], toZigbee: [], exposes: [ e.battery(), e.action(['enter', 'leave', 'sleep', 'wakeup', 'center']), ], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genIdentify', 'genPowerCfg']); }, }, { fingerprint: [{ modelID: 'GreenPower_254', ieeeAddr: /^0x00000000005.....$/ }], model: 'ZLGP14/ZLGP15/ZLGP16', vendor: 'Legrand', description: 'Wireless and batteryless scenario switch (home arrival/departure, 1-4 switches, daytime day/night)', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.legrand_greenpower], toZigbee: [], exposes: [e.action([ 'home_arrival', 'home_departure', // ZLGP14 'press_1', 'press_2', 'press_3', 'press_4', // ZLGP15 'daytime_day', 'daytime_night', // ZLGP16 ])], }, { fingerprint: [{ modelID: 'GreenPower_2', ieeeAddr: /^0x00000000005.....$/ }], model: 'ZLGP17/ZLGP18', vendor: 'Legrand', description: 'Wireless and batteryless (double) lighting control', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.legrand_greenpower], toZigbee: [], exposes: [e.action(['press_once', 'press_twice'])], }, { fingerprint: [{ modelID: 'GreenPower_3', ieeeAddr: /^0x00000000005.....$/ }], model: '600087L', vendor: 'Legrand', description: 'Wireless and batteryless blind control switch', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.legrand_greenpower], toZigbee: [], exposes: [e.action(['stop', 'up', 'down'])], }, { zigbeeModel: [' Cable outlet\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000' + '\u0000\u0000'], model: '064882', vendor: 'Legrand', description: 'Cable outlet with pilot wire and consumption measurement', ota: ota.zigbeeOTA, fromZigbee: [legrand_1.fzLegrand.cluster_fc01, fromZigbee_1.default.legrand_pilot_wire_mode, fromZigbee_1.default.on_off, fromZigbee_1.default.electrical_measurement, fromZigbee_1.default.power_on_behavior], toZigbee: [toZigbee_1.default.legrand_device_mode, toZigbee_1.default.legrand_pilot_wire_mode, toZigbee_1.default.on_off, toZigbee_1.default.electrical_measurement_power, toZigbee_1.default.power_on_behavior], exposes: [ e.binary('device_mode', ea.ALL, 'pilot_on', 'pilot_off'), e.pilot_wire_mode(), e.switch().withState('state', true, 'Works only when the pilot wire is deactivated'), e.power().withAccess(ea.STATE_GET), e.power_apparent(), e.power_on_behavior() .withDescription('Controls the behavior when the device is powered on. Works only when the pilot wire is deactivated'), ], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff', 'haElectricalMeasurement', 'manuSpecificLegrandDevices2']); await reporting.onOff(endpoint); await reporting.readEletricalMeasurementMultiplierDivisors(endpoint); await reporting.activePower(endpoint); await reporting.apparentPower(endpoint); }, }, { zigbeeModel: [' NLIS - Double light switch\u0000\u0000\u0000\u0000'], model: '067772', vendor: 'Legrand', description: 'Double wired switch with neutral', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.legrand_binary_input_on_off, fromZigbee_1.default.lighting_ballast_configuration, legrand_1.fzLegrand.cluster_fc01], toZigbee: [legrand_1.tzLegrand.identify, toZigbee_1.default.legrand_device_mode, legrand_1.tzLegrand.led_mode, toZigbee_1.default.ballast_config], exposes: [ e.numeric('ballast_minimum_level', ea.ALL).withValueMin(1).withValueMax(254) .withDescription('Specifies the minimum brightness value').withEndpoint('left'), e.numeric('ballast_maximum_level', ea.ALL).withValueMin(1).withValueMax(254) .withDescription('Specifies the maximum brightness value').withEndpoint('left'), e.numeric('ballast_minimum_level', ea.ALL).withValueMin(1).withValueMax(254) .withDescription('Specifies the minimum brightness value').withEndpoint('right'), e.numeric('ballast_maximum_level', ea.ALL).withValueMin(1).withValueMax(254) .withDescription('Specifies the maximum brightness value').withEndpoint('right'), e.binary('device_mode', ea.ALL, 'dimmer_on', 'dimmer_off') .withDescription('Allow the device to change brightness'), e.switch().withEndpoint('left'), e.switch().withEndpoint('right'), legrand_1.eLegrand.ledInDark(), legrand_1.eLegrand.ledIfOn(), ], extend: [(0, modernExtend_1.deviceEndpoints)({ endpoints: { 'left': 2, 'right': 1 } }), (0, modernExtend_1.light)({ configureReporting: true, endpointNames: ['left', 'right'] })], }, { zigbeeModel: [' Mobile outlet\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000\u0000'], model: 'WNRR15/WNRR20', vendor: 'Legrand', description: 'Outlet with power consumption monitoring', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.on_off, fromZigbee_1.default.electrical_measurement, legrand_1.fzLegrand.cluster_fc01], toZigbee: [toZigbee_1.default.on_off, legrand_1.tzLegrand.led_mode, legrand_1.tzLegrand.identify], exposes: [ e.switch(), e.action(['identify']), e.power(), ], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genIdentify', 'genOnOff', 'haElectricalMeasurement']); await reporting.onOff(endpoint); await reporting.readEletricalMeasurementMultiplierDivisors(endpoint); await reporting.activePower(endpoint); }, }, { zigbeeModel: ['Hospitality on off switch'], model: 'WNAL10/WNRL10', vendor: 'Legrand', description: 'Smart switch with Netatmo', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.on_off, fromZigbee_1.default.legrand_binary_input_on_off, legrand_1.fzLegrand.cluster_fc01], toZigbee: [toZigbee_1.default.on_off, legrand_1.tzLegrand.led_mode], exposes: [ e.switch(), legrand_1.eLegrand.ledInDark(), legrand_1.eLegrand.ledIfOn(), ], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff']); await reporting.onOff(endpoint); }, }, { zigbeeModel: ['Hospitality dimmer switch'], model: 'WNAL50/WNRL50', vendor: 'Legrand', description: 'Smart dimmer switch with Netatmo', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.lighting_ballast_configuration, legrand_1.fzLegrand.cluster_fc01], toZigbee: [legrand_1.tzLegrand.led_mode, toZigbee_1.default.legrand_device_mode, legrand_1.tzLegrand.identify, toZigbee_1.default.ballast_config], exposes: [ e.numeric('ballast_minimum_level', ea.ALL).withValueMin(1).withValueMax(254) .withDescription('Specifies the minimum brightness value'), e.numeric('ballast_maximum_level', ea.ALL).withValueMin(1).withValueMax(254) .withDescription('Specifies the maximum brightness value'), e.binary('device_mode', ea.ALL, 'dimmer_on', 'dimmer_off') .withDescription('Allow the device to change brightness'), legrand_1.eLegrand.ledInDark(), legrand_1.eLegrand.ledIfOn(), ], extend: [(0, modernExtend_1.light)({ configureReporting: true })], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genIdentify', 'genBinaryInput', 'lightingBallastCfg']); }, }, { // LED blinks RED when battery is low zigbeeModel: ['Remote dimmer switch'], model: 'WNAL63', vendor: 'Legrand', description: 'Remote dimmer switch', ota: ota.zigbeeOTA, meta: { battery: { voltageToPercentage: '3V_2500' }, publishDuplicateTransaction: true }, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.command_on, fromZigbee_1.default.command_off, fromZigbee_1.default.command_toggle, legacy.fz.cmd_move, legacy.fz.cmd_stop, fromZigbee_1.default.battery], toZigbee: [], exposes: [ e.battery(), e.action(['identify', 'on', 'off', 'toggle', 'brightness_move_up', 'brightness_move_down', 'brightness_stop']), ], onEvent: legrand_1.readInitialBatteryState, configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genIdentify', 'genOnOff', 'genLevelCtrl']); }, }, { zigbeeModel: [' Centralized ventilation SW', ' Centralized ventilation SW\u0000\u0000\u0000\u0000', ], model: '067766', vendor: 'Legrand', description: 'Centralized ventilation switch', ota: ota.zigbeeOTA, fromZigbee: [fromZigbee_1.default.identify, fromZigbee_1.default.on_off, fromZigbee_1.default.power_on_behavior, legrand_1.fzLegrand.cluster_fc01], toZigbee: [toZigbee_1.default.on_off, legrand_1.tzLegrand.led_mode, legrand_1.tzLegrand.identify, toZigbee_1.default.power_on_behavior], exposes: [ e.switch(), e.action(['identify']), legrand_1.eLegrand.ledInDark(), legrand_1.eLegrand.ledIfOn(), e.power_on_behavior(), ], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genIdentify', 'genOnOff']); await reporting.onOff(endpoint); }, }, ]; exports.default = definitions; module.exports = definitions; //# sourceMappingURL=legrand.js.map