UNPKG

zigbee-herdsman-converters

Version:

Collection of device converters to be used with zigbee-herdsman

759 lines • 38.5 kB
"use strict"; var __createBinding = (this && this.__createBinding) || (Object.create ? (function(o, m, k, k2) { if (k2 === undefined) k2 = k; var desc = Object.getOwnPropertyDescriptor(m, k); if (!desc || ("get" in desc ? !m.__esModule : desc.writable || desc.configurable)) { desc = { enumerable: true, get: function() { return m[k]; } }; } Object.defineProperty(o, k2, desc); }) : (function(o, m, k, k2) { if (k2 === undefined) k2 = k; o[k2] = m[k]; })); var __setModuleDefault = (this && this.__setModuleDefault) || (Object.create ? (function(o, v) { Object.defineProperty(o, "default", { enumerable: true, value: v }); }) : function(o, v) { o["default"] = v; }); var __importStar = (this && this.__importStar) || function (mod) { if (mod && mod.__esModule) return mod; var result = {}; if (mod != null) for (var k in mod) if (k !== "default" && Object.prototype.hasOwnProperty.call(mod, k)) __createBinding(result, mod, k); __setModuleDefault(result, mod); return result; }; var __importDefault = (this && this.__importDefault) || function (mod) { return (mod && mod.__esModule) ? mod : { "default": mod }; }; Object.defineProperty(exports, "__esModule", { value: true }); const exposes = __importStar(require("../lib/exposes")); const fromZigbee_1 = __importDefault(require("../converters/fromZigbee")); const legacy = __importStar(require("../lib/legacy")); const toZigbee_1 = __importDefault(require("../converters/toZigbee")); const constants = __importStar(require("../lib/constants")); const reporting = __importStar(require("../lib/reporting")); const e = exposes.presets; const ea = exposes.access; const tuya = __importStar(require("../lib/tuya")); const modernExtend_1 = require("../lib/modernExtend"); const definitions = [ { zigbeeModel: ['PIRILLSensor-EF-3.0'], model: 'HS1MIS-3.0', vendor: 'HEIMAN', description: 'Smart occupancy sensor', fromZigbee: [fromZigbee_1.default.occupancy, fromZigbee_1.default.battery, fromZigbee_1.default.illuminance], toZigbee: [], exposes: [e.occupancy(), e.battery(), e.illuminance()], configure: async (device, cordinatorEndpoint) => { const endpoint1 = device.getEndpoint(1); await reporting.bind(endpoint1, cordinatorEndpoint, ['msOccupancySensing', 'genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint1); await reporting.occupancy(endpoint1); await reporting.bind(endpoint1, cordinatorEndpoint, ['msIlluminanceMeasurement']); await reporting.illuminance(endpoint1); }, }, { fingerprint: [{ modelID: 'TS0212', manufacturerName: '_TYZB01_wpmo3ja3' }], zigbeeModel: ['CO_V15', 'CO_YDLV10', 'CO_V16', '1ccaa94c49a84abaa9e38687913947ba', 'CO_CTPG'], model: 'HS1CA-M', description: 'Smart carbon monoxide sensor', vendor: 'HEIMAN', fromZigbee: [fromZigbee_1.default.ias_carbon_monoxide_alarm_1, fromZigbee_1.default.battery], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); await reporting.batteryAlarmState(endpoint); }, exposes: [e.carbon_monoxide(), e.battery_low(), e.battery()], }, { zigbeeModel: ['PIRSensor-N', 'PIRSensor-EM', 'PIRSensor-EF-3.0', 'PIR_TPV13'], model: 'HS3MS', vendor: 'HEIMAN', description: 'Smart motion sensor', fromZigbee: [fromZigbee_1.default.ias_occupancy_alarm_1], toZigbee: [], exposes: [e.occupancy(), e.battery_low(), e.tamper()], }, { zigbeeModel: ['SmartPlug', 'SmartPlug-EF-3.0'], model: 'HS2SK', description: 'Smart metering plug', vendor: 'HEIMAN', fromZigbee: [fromZigbee_1.default.on_off, fromZigbee_1.default.electrical_measurement, fromZigbee_1.default.metering], toZigbee: [toZigbee_1.default.on_off], whiteLabel: [{ vendor: 'Schneider Electric', model: 'CCTFR6500' }], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff', 'haElectricalMeasurement', 'seMetering']); await reporting.onOff(endpoint); await reporting.readEletricalMeasurementMultiplierDivisors(endpoint); await reporting.rmsVoltage(endpoint); await reporting.rmsCurrent(endpoint); await reporting.activePower(endpoint); await reporting.readMeteringMultiplierDivisor(endpoint); await reporting.currentSummDelivered(endpoint); }, exposes: [e.switch(), e.power(), e.current(), e.voltage(), e.energy()], }, { fingerprint: [{ modelID: 'SmartPlug-N', manufacturerName: 'HEIMAN' }], model: 'HS2SK_nxp', description: 'Smart metering plug', vendor: 'HEIMAN', fromZigbee: [fromZigbee_1.default.on_off, fromZigbee_1.default.electrical_measurement], toZigbee: [toZigbee_1.default.on_off], options: [exposes.options.measurement_poll_interval()], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff', 'haElectricalMeasurement']); await reporting.onOff(endpoint); await reporting.readEletricalMeasurementMultiplierDivisors(endpoint); }, onEvent: (type, data, device, settings) => tuya.onEventMeasurementPoll(type, data, device, settings), exposes: [e.switch(), e.power(), e.current(), e.voltage()], }, { zigbeeModel: ['SMOK_V16', 'SMOK_V15', 'b5db59bfd81e4f1f95dc57fdbba17931', '98293058552c49f38ad0748541ee96ba', 'SMOK_YDLV10', 'FB56-SMF02HM1.4', 'SmokeSensor-N-3.0', '319fa36e7384414a9ea62cba8f6e7626', 'c3442b4ac59b4ba1a83119d938f283ab', 'SmokeSensor-EF-3.0', 'SMOK_HV14'], model: 'HS1SA', vendor: 'HEIMAN', description: 'Smoke detector', fromZigbee: [fromZigbee_1.default.ias_smoke_alarm_1, fromZigbee_1.default.battery], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); }, exposes: [e.smoke(), e.battery_low(), e.battery()], }, { zigbeeModel: ['SmokeSensor-N', 'SmokeSensor-EM'], model: 'HS3SA/HS1SA', vendor: 'HEIMAN', description: 'Smoke detector', fromZigbee: [fromZigbee_1.default.ias_smoke_alarm_1, fromZigbee_1.default.battery], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); }, exposes: [e.smoke(), e.battery_low(), e.battery()], }, { zigbeeModel: ['GASSensor-N', 'GASSensor-N-3.0', 'd90d7c61c44d468a8e906ca0841e0a0c'], model: 'HS3CG', vendor: 'HEIMAN', description: 'Combustible gas sensor', fromZigbee: [fromZigbee_1.default.ias_gas_alarm_2], toZigbee: [], exposes: [e.gas(), e.battery_low(), e.tamper()], }, { zigbeeModel: ['GASSensor-EN'], model: 'HS1CG-M', vendor: 'HEIMAN', description: 'Combustible gas sensor', fromZigbee: [fromZigbee_1.default.ias_gas_alarm_1], toZigbee: [], exposes: [e.gas(), e.battery_low(), e.tamper()], }, { zigbeeModel: ['RH3070'], model: 'HS1CG', vendor: 'HEIMAN', description: 'Smart combustible gas sensor', fromZigbee: [fromZigbee_1.default.ias_gas_alarm_1], toZigbee: [], exposes: [e.gas(), e.battery_low(), e.tamper()], }, { zigbeeModel: ['GAS_V15'], model: 'HS1CG_M', vendor: 'HEIMAN', description: 'Combustible gas sensor', fromZigbee: [fromZigbee_1.default.ias_gas_alarm_2], toZigbee: [], exposes: [e.gas(), e.battery_low(), e.tamper()], }, { zigbeeModel: ['DoorSensor-N', 'DoorSensor-N-3.0'], model: 'HS3DS', vendor: 'HEIMAN', description: 'Door sensor', fromZigbee: [fromZigbee_1.default.ias_contact_alarm_1, fromZigbee_1.default.battery], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); await endpoint.read('genPowerCfg', ['batteryPercentageRemaining']); }, exposes: [e.contact(), e.battery(), e.battery_low(), e.tamper()], }, { zigbeeModel: ['DoorSensor-EM', 'DoorSensor-EF-3.0'], model: 'HS1DS', vendor: 'HEIMAN', description: 'Door sensor', fromZigbee: [fromZigbee_1.default.ias_contact_alarm_1, fromZigbee_1.default.battery], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); await endpoint.read('genPowerCfg', ['batteryPercentageRemaining']); }, exposes: [e.contact(), e.battery_low(), e.tamper(), e.battery()], }, { zigbeeModel: ['DOOR_TPV13', 'DOOR_TPV12'], model: 'HEIMAN-M1', vendor: 'HEIMAN', description: 'Door sensor', fromZigbee: [fromZigbee_1.default.ias_contact_alarm_1], toZigbee: [], exposes: [e.contact(), e.battery_low(), e.tamper()], }, { zigbeeModel: ['WaterSensor-N', 'WaterSensor-EM', 'WaterSensor-N-3.0', 'WaterSensor-EF-3.0', 'WaterSensor2-EF-3.0', 'WATER_TPV13'], model: 'HS1WL/HS3WL', vendor: 'HEIMAN', description: 'Water leakage sensor', fromZigbee: [fromZigbee_1.default.ias_water_leak_alarm_1, fromZigbee_1.default.battery], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); await endpoint.read('genPowerCfg', ['batteryPercentageRemaining']); }, exposes: [e.water_leak(), e.battery_low(), e.tamper(), e.battery()], }, { fingerprint: [{ modelID: 'RC-N', manufacturerName: 'HEIMAN' }], model: 'HS1RC-N', vendor: 'HEIMAN', description: 'Smart remote controller', fromZigbee: [fromZigbee_1.default.battery, legacy.fz.heiman_smart_controller_armmode, fromZigbee_1.default.command_emergency], toZigbee: [], exposes: [e.battery(), e.action(['emergency', 'disarm', 'arm_partial_zones', 'arm_all_zones'])], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); await endpoint.read('genPowerCfg', ['batteryPercentageRemaining']); }, }, { fingerprint: [{ modelID: 'RC-EF-3.0', manufacturerName: 'HEIMAN' }], model: 'HM1RC-2-E', vendor: 'HEIMAN', description: 'Smart remote controller', fromZigbee: [fromZigbee_1.default.battery, fromZigbee_1.default.command_arm, fromZigbee_1.default.command_emergency], toZigbee: [], exposes: [e.battery(), e.action(['emergency', 'disarm', 'arm_day_zones', 'arm_all_zones'])], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); await endpoint.read('genPowerCfg', ['batteryPercentageRemaining']); }, onEvent: async (type, data, device) => { // Since arm command has a response zigbee-herdsman doesn't send a default response. // This causes the remote to repeat the arm command, so send a default response here. if (data.type === 'commandArm' && data.cluster === 'ssIasAce') { await data.endpoint.defaultResponse(0, 0, 1281, data.meta.zclTransactionSequenceNumber); } }, }, { fingerprint: [{ modelID: 'RC-EM', manufacturerName: 'HEIMAN' }], model: 'HS1RC-EM', vendor: 'HEIMAN', description: 'Smart remote controller', fromZigbee: [fromZigbee_1.default.battery, legacy.fz.heiman_smart_controller_armmode, fromZigbee_1.default.command_emergency], toZigbee: [], exposes: [e.battery(), e.action(['emergency', 'disarm', 'arm_partial_zones', 'arm_all_zones'])], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); await endpoint.read('genPowerCfg', ['batteryPercentageRemaining']); }, }, { zigbeeModel: ['COSensor-EM', 'COSensor-N', 'COSensor-EF-3.0'], model: 'HS1CA-E', vendor: 'HEIMAN', description: 'Smart carbon monoxide sensor', fromZigbee: [fromZigbee_1.default.ias_carbon_monoxide_alarm_1, fromZigbee_1.default.battery], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); }, exposes: [e.carbon_monoxide(), e.battery_low(), e.battery()], }, { fingerprint: [{ modelID: 'TS0216', manufacturerName: '_TYZB01_8scntis1' }, { modelID: 'TS0216', manufacturerName: '_TYZB01_4obovpbi' }], zigbeeModel: ['WarningDevice', 'WarningDevice-EF-3.0'], model: 'HS2WD-E', vendor: 'HEIMAN', description: 'Smart siren', fromZigbee: [fromZigbee_1.default.battery, fromZigbee_1.default.ignore_basic_report], toZigbee: [toZigbee_1.default.warning], meta: { disableDefaultResponse: true }, configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); }, exposes: [e.battery(), e.warning()], }, { zigbeeModel: ['HT-EM', 'TH-EM', 'TH-T_V14'], model: 'HS1HT', vendor: 'HEIMAN', description: 'Smart temperature & humidity Sensor', exposes: [e.battery(), e.temperature(), e.humidity()], fromZigbee: [fromZigbee_1.default.temperature, fromZigbee_1.default.humidity, fromZigbee_1.default.battery], toZigbee: [], meta: { battery: { voltageToPercentage: '3V_2500' } }, whiteLabel: [{ vendor: 'Ferguson', model: 'TH-T_V14' }], configure: async (device, coordinatorEndpoint) => { const endpoint1 = device.getEndpoint(1); await reporting.bind(endpoint1, coordinatorEndpoint, ['msTemperatureMeasurement']); const endpoint2 = device.getEndpoint(2); await reporting.bind(endpoint2, coordinatorEndpoint, ['msRelativeHumidity', 'genPowerCfg']); await reporting.temperature(endpoint1); await reporting.humidity(endpoint2); await reporting.batteryVoltage(endpoint2); await reporting.batteryPercentageRemaining(endpoint2); }, }, { zigbeeModel: ['HT-N', 'HT-EF-3.0'], model: 'HS1HT-N', vendor: 'HEIMAN', description: 'Smart temperature & humidity Sensor', fromZigbee: [fromZigbee_1.default.temperature, fromZigbee_1.default.humidity, fromZigbee_1.default.battery], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint1 = device.getEndpoint(1); await reporting.bind(endpoint1, coordinatorEndpoint, ['msTemperatureMeasurement', 'genPowerCfg']); await reporting.temperature(endpoint1); await reporting.batteryPercentageRemaining(endpoint1); await endpoint1.read('genPowerCfg', ['batteryPercentageRemaining']); const endpoint2 = device.getEndpoint(2); await reporting.bind(endpoint2, coordinatorEndpoint, ['msRelativeHumidity']); await reporting.humidity(endpoint2); }, exposes: [e.temperature(), e.humidity(), e.battery()], }, { zigbeeModel: ['E_Socket'], model: 'HS2ESK-E', vendor: 'HEIMAN', description: 'Smart in wall plug', fromZigbee: [fromZigbee_1.default.on_off, fromZigbee_1.default.electrical_measurement], toZigbee: [toZigbee_1.default.on_off], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff', 'haElectricalMeasurement']); await reporting.onOff(endpoint); await reporting.readEletricalMeasurementMultiplierDivisors(endpoint); await reporting.rmsVoltage(endpoint); await reporting.rmsCurrent(endpoint); await reporting.activePower(endpoint); }, exposes: [e.switch(), e.power(), e.current(), e.voltage()], }, { fingerprint: [{ modelID: 'SOS-EM', manufacturerName: 'HEIMAN' }, { modelID: 'SOS-EF-3.0', manufacturerName: 'HEIMAN' }], model: 'HS1EB/HS1EB-E', vendor: 'HEIMAN', description: 'Smart emergency button', fromZigbee: [fromZigbee_1.default.command_status_change_notification_action, legacy.fz.st_button_state, fromZigbee_1.default.battery], toZigbee: [], exposes: [e.battery(), e.action(['off', 'single', 'double', 'hold'])], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); await endpoint.read('genPowerCfg', ['batteryPercentageRemaining']); }, }, { fingerprint: [{ modelID: 'SceneSwitch-EM-3.0', manufacturerName: 'HEIMAN' }], model: 'HS2SS', vendor: 'HEIMAN', description: 'Smart scene switch', fromZigbee: [fromZigbee_1.default.battery, fromZigbee_1.default.heiman_scenes], exposes: [e.battery(), e.action(['cinema', 'at_home', 'sleep', 'go_out', 'repast'])], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg', 'heimanSpecificScenes']); await reporting.batteryPercentageRemaining(endpoint); }, }, { zigbeeModel: ['TempDimmerSw-EM-3.0'], model: 'HS2WDSC-E', vendor: 'HEIMAN', description: 'Remote dimmer and temperature control', fromZigbee: [fromZigbee_1.default.battery, fromZigbee_1.default.command_on, fromZigbee_1.default.command_off, fromZigbee_1.default.command_move, fromZigbee_1.default.command_stop, fromZigbee_1.default.command_move_to_color, fromZigbee_1.default.command_move_to_color_temp], exposes: [e.battery(), e.action(['on', 'off', 'move', 'stop', 'color_move', 'color_temperature_move'])], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg', 'genOnOff', 'genLevelCtrl', 'lightingColorCtrl']); await reporting.batteryPercentageRemaining(endpoint, { min: constants.repInterval.MINUTES_5, max: constants.repInterval.HOUR }); }, }, { fingerprint: [{ modelID: 'ColorDimmerSw-EM-3.0', manufacturerName: 'HEIMAN' }], model: 'HS2WDSR-E', vendor: 'HEIMAN', description: 'Remote dimmer and color control', fromZigbee: [fromZigbee_1.default.battery, fromZigbee_1.default.command_on, fromZigbee_1.default.command_off, fromZigbee_1.default.command_move, fromZigbee_1.default.command_stop, fromZigbee_1.default.command_move_to_color], exposes: [e.battery(), e.action(['on', 'off', 'move', 'stop', 'color_move'])], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg', 'genOnOff', 'genLevelCtrl', 'lightingColorCtrl']); await reporting.batteryPercentageRemaining(endpoint, { min: constants.repInterval.MINUTES_5, max: constants.repInterval.HOUR }); }, }, { zigbeeModel: ['HS3HT-EFA-3.0'], model: 'HS3HT', vendor: 'HEIMAN', description: 'Temperature & humidity sensor with display', fromZigbee: [fromZigbee_1.default.temperature, fromZigbee_1.default.humidity, fromZigbee_1.default.battery], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint1 = device.getEndpoint(1); await reporting.bind(endpoint1, coordinatorEndpoint, ['msTemperatureMeasurement', 'genPowerCfg']); await reporting.temperature(endpoint1); await reporting.batteryPercentageRemaining(endpoint1); await endpoint1.read('genPowerCfg', ['batteryPercentageRemaining']); const endpoint2 = device.getEndpoint(2); await reporting.bind(endpoint2, coordinatorEndpoint, ['msRelativeHumidity']); await reporting.humidity(endpoint2); }, exposes: [e.battery(), e.temperature(), e.humidity()], }, { zigbeeModel: ['GASSensor-EM', '358e4e3e03c644709905034dae81433e'], model: 'HS1CG-E', vendor: 'HEIMAN', description: 'Combustible gas sensor', fromZigbee: [fromZigbee_1.default.ias_gas_alarm_1], toZigbee: [], whiteLabel: [{ vendor: 'Piri', model: 'HSIO18008' }], exposes: [e.gas(), e.battery_low(), e.tamper()], }, { zigbeeModel: ['GASSensor-EFR-3.0', 'GASSensor-EF-3.0'], model: 'HS1CG-E_3.0', vendor: 'HEIMAN', description: 'Combustible gas sensor', fromZigbee: [fromZigbee_1.default.ias_gas_alarm_2], toZigbee: [], exposes: [e.gas(), e.battery_low(), e.tamper()], }, { fingerprint: [{ modelID: 'Vibration-N', manufacturerName: 'HEIMAN' }], model: 'HS1VS-N', vendor: 'HEIMAN', description: 'Vibration sensor', fromZigbee: [fromZigbee_1.default.ias_vibration_alarm_1, fromZigbee_1.default.battery], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); await endpoint.read('genPowerCfg', ['batteryPercentageRemaining']); }, exposes: [e.vibration(), e.battery_low(), e.tamper(), e.battery()], }, { fingerprint: [{ modelID: 'Vibration-EF_3.0', manufacturerName: 'HEIMAN' }, { modelID: 'Vibration-EF-3.0', manufacturerName: 'HEIMAN' }], model: 'HS1VS-EF', vendor: 'HEIMAN', description: 'Vibration sensor', fromZigbee: [fromZigbee_1.default.ias_vibration_alarm_1, fromZigbee_1.default.battery], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); await endpoint.read('genPowerCfg', ['batteryPercentageRemaining']); }, exposes: [e.vibration(), e.battery_low(), e.tamper(), e.battery()], }, { fingerprint: [{ modelID: 'HS2AQ-EM', manufacturerName: 'HEIMAN' }], model: 'HS2AQ-EM', vendor: 'HEIMAN', description: 'Air quality monitor', fromZigbee: [fromZigbee_1.default.battery, fromZigbee_1.default.temperature, fromZigbee_1.default.humidity, fromZigbee_1.default.pm25, fromZigbee_1.default.heiman_hcho, fromZigbee_1.default.heiman_air_quality], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const heiman = { configureReporting: { pm25MeasuredValue: async (endpoint, overrides) => { const payload = reporting.payload('measuredValue', 0, constants.repInterval.HOUR, 1, overrides); await endpoint.configureReporting('pm25Measurement', payload); }, formAldehydeMeasuredValue: async (endpoint, overrides) => { const payload = reporting.payload('measuredValue', 0, constants.repInterval.HOUR, 1, overrides); await endpoint.configureReporting('heimanSpecificFormaldehydeMeasurement', payload); }, batteryState: async (endpoint, overrides) => { const payload = reporting.payload('batteryState', 0, constants.repInterval.HOUR, 1, overrides); await endpoint.configureReporting('heimanSpecificAirQuality', payload); }, pm10measuredValue: async (endpoint, overrides) => { const payload = reporting.payload('pm10measuredValue', 0, constants.repInterval.HOUR, 1, overrides); await endpoint.configureReporting('heimanSpecificAirQuality', payload); }, tvocMeasuredValue: async (endpoint, overrides) => { const payload = reporting.payload('tvocMeasuredValue', 0, constants.repInterval.HOUR, 1, overrides); await endpoint.configureReporting('heimanSpecificAirQuality', payload); }, aqiMeasuredValue: async (endpoint, overrides) => { const payload = reporting.payload('aqiMeasuredValue', 0, constants.repInterval.HOUR, 1, overrides); await endpoint.configureReporting('heimanSpecificAirQuality', payload); }, }, }; const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, [ 'genPowerCfg', 'genTime', 'msTemperatureMeasurement', 'msRelativeHumidity', 'pm25Measurement', 'heimanSpecificFormaldehydeMeasurement', 'heimanSpecificAirQuality' ]); await reporting.batteryPercentageRemaining(endpoint); await reporting.temperature(endpoint); await reporting.humidity(endpoint); await heiman.configureReporting.pm25MeasuredValue(endpoint); await heiman.configureReporting.formAldehydeMeasuredValue(endpoint); await heiman.configureReporting.batteryState(endpoint); await heiman.configureReporting.pm10measuredValue(endpoint); await heiman.configureReporting.tvocMeasuredValue(endpoint); await heiman.configureReporting.aqiMeasuredValue(endpoint); await endpoint.read('genPowerCfg', ['batteryPercentageRemaining']); // Seems that it is bug in HEIMAN, device does not asks for the time with binding // So, we need to write time during configure const time = Math.round(((new Date()).getTime() - constants.OneJanuary2000) / 1000); // Time-master + synchronised const values = { timeStatus: 3, time: time, timeZone: ((new Date()).getTimezoneOffset() * -1) * 60 }; endpoint.write('genTime', values); }, exposes: [e.battery(), e.temperature(), e.humidity(), e.pm25(), e.hcho(), e.voc(), e.aqi(), e.pm10(), e.enum('battery_state', ea.STATE, ['not_charging', 'charging', 'charged'])], }, { fingerprint: [{ modelID: 'IRControl-EM', manufacturerName: 'HEIMAN' }], model: 'HS2IRC', vendor: 'HEIMAN', description: 'Smart IR Control', fromZigbee: [fromZigbee_1.default.battery, fromZigbee_1.default.heiman_ir_remote], toZigbee: [toZigbee_1.default.heiman_ir_remote], exposes: [e.battery()], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg', 'heimanSpecificInfraRedRemote']); await reporting.batteryPercentageRemaining(endpoint); }, }, { zigbeeModel: ['HS2SW1L-EF-3.0', 'HS2SW1L-EFR-3.0', 'HS2SW1A-N'], fingerprint: [ { modelID: 'HS2SW1A-EF-3.0', manufacturerName: 'HEIMAN' }, { modelID: 'HS2SW1A-EFR-3.0', manufacturerName: 'HEIMAN' }, ], model: 'HS2SW1A/HS2SW1A-N', vendor: 'HEIMAN', description: 'Smart switch - 1 gang with neutral wire', fromZigbee: [fromZigbee_1.default.ignore_basic_report, fromZigbee_1.default.on_off, fromZigbee_1.default.device_temperature], toZigbee: [toZigbee_1.default.on_off], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff', 'genDeviceTempCfg']); await reporting.onOff(endpoint); await reporting.deviceTemperature(endpoint); }, exposes: [e.switch(), e.device_temperature()], }, { zigbeeModel: ['HS2SW2L-EF-3.0', 'HS2SW2L-EFR-3.0', 'HS2SW2A-N'], fingerprint: [ { modelID: 'HS2SW2A-EF-3.0', manufacturerName: 'HEIMAN' }, { modelID: 'HS2SW2A-EFR-3.0', manufacturerName: 'HEIMAN' }, ], model: 'HS2SW2A/HS2SW2A-N', vendor: 'HEIMAN', description: 'Smart switch - 2 gang with neutral wire', fromZigbee: [fromZigbee_1.default.ignore_basic_report, fromZigbee_1.default.on_off, fromZigbee_1.default.device_temperature], toZigbee: [toZigbee_1.default.on_off], endpoint: (device) => { return { left: 1, right: 2 }; }, meta: { multiEndpoint: true }, configure: async (device, coordinatorEndpoint) => { await reporting.bind(device.getEndpoint(1), coordinatorEndpoint, ['genOnOff', 'genDeviceTempCfg']); await reporting.bind(device.getEndpoint(2), coordinatorEndpoint, ['genOnOff']); await reporting.deviceTemperature(device.getEndpoint(1)); }, exposes: [e.switch().withEndpoint('left'), e.switch().withEndpoint('right'), e.device_temperature()], }, { zigbeeModel: ['HS2SW3L-EF-3.0', 'HS2SW3L-EFR-3.0', 'HS2SW3A-N'], fingerprint: [ { modelID: 'HS2SW3A-EF-3.0', manufacturerName: 'HEIMAN' }, { modelID: 'HS2SW3A-EFR-3.0', manufacturerName: 'HEIMAN' }, ], model: 'HS2SW3A/HS2SW3A-N', vendor: 'HEIMAN', description: 'Smart switch - 3 gang with neutral wire', fromZigbee: [fromZigbee_1.default.ignore_basic_report, fromZigbee_1.default.on_off, fromZigbee_1.default.device_temperature], toZigbee: [toZigbee_1.default.on_off], endpoint: (device) => { return { left: 1, center: 2, right: 3 }; }, meta: { multiEndpoint: true }, configure: async (device, coordinatorEndpoint) => { await reporting.bind(device.getEndpoint(1), coordinatorEndpoint, ['genOnOff', 'genDeviceTempCfg']); await reporting.bind(device.getEndpoint(2), coordinatorEndpoint, ['genOnOff']); await reporting.bind(device.getEndpoint(3), coordinatorEndpoint, ['genOnOff']); await reporting.deviceTemperature(device.getEndpoint(1)); }, exposes: [e.switch().withEndpoint('left'), e.switch().withEndpoint('center'), e.switch().withEndpoint('right'), e.device_temperature()], }, { zigbeeModel: ['TemperLight'], model: 'HS2WDS', vendor: 'HEIMAN', description: 'LED 9W CCT E27', extend: [(0, modernExtend_1.light)({ colorTemp: { range: [153, 370] } })], }, { zigbeeModel: ['CurtainMo-EF-3.0', 'CurtainMo-EF'], model: 'HS2CM-N-DC', vendor: 'HEIMAN', description: 'Gear window shade motor', fromZigbee: [fromZigbee_1.default.cover_position_via_brightness], toZigbee: [toZigbee_1.default.cover_via_brightness], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genLevelCtrl', 'genPowerCfg']); await reporting.brightness(endpoint); }, exposes: [e.cover_position().setAccess('state', ea.ALL)], }, { zigbeeModel: ['PIR_TPV16'], model: 'HS1MS-M', vendor: 'HEIMAN', description: 'Smart motion sensor', fromZigbee: [fromZigbee_1.default.ias_occupancy_alarm_1], toZigbee: [], exposes: [e.occupancy(), e.battery_low(), e.tamper()], }, { zigbeeModel: ['TY0202'], model: 'HS1MS-EF', vendor: 'HEIMAN', description: 'Smart motion sensor', fromZigbee: [fromZigbee_1.default.ias_occupancy_alarm_1], toZigbee: [], exposes: [e.occupancy(), e.battery_low(), e.tamper()], }, { fingerprint: [{ modelID: 'DoorBell-EM', manufacturerName: 'HEIMAN' }], model: 'HS2DB', vendor: 'HEIMAN', description: 'Smart doorbell button', fromZigbee: [fromZigbee_1.default.battery, fromZigbee_1.default.heiman_doorbell_button, fromZigbee_1.default.ignore_basic_report], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); }, exposes: [e.battery(), e.action(['pressed']), e.battery_low(), e.tamper()], }, { fingerprint: [{ modelID: 'DoorBell-EF-3.0', manufacturerName: 'HEIMAN' }], model: 'HS2SS-E_V03', vendor: 'HEIMAN', description: 'Smart doorbell button', fromZigbee: [fromZigbee_1.default.battery, fromZigbee_1.default.heiman_doorbell_button, fromZigbee_1.default.ignore_basic_report], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg']); await reporting.batteryPercentageRemaining(endpoint); }, exposes: [e.battery(), e.action(['pressed']), e.battery_low(), e.tamper()], }, { zigbeeModel: ['HS3AQ-EFA-3.0'], model: 'HS3AQ', vendor: 'HEIMAN', description: 'Smart air quality monitor', fromZigbee: [fromZigbee_1.default.co2, fromZigbee_1.default.humidity, fromZigbee_1.default.battery, fromZigbee_1.default.temperature], toZigbee: [], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['msRelativeHumidity', 'genPowerCfg', 'msTemperatureMeasurement', 'msCO2']); await reporting.batteryPercentageRemaining(endpoint); await reporting.temperature(endpoint, { min: 1, max: constants.repInterval.MINUTES_5, change: 10 }); // 0.1 degree change await reporting.humidity(endpoint, { min: 1, max: constants.repInterval.MINUTES_5, change: 10 }); // 0.1 % change await reporting.co2(endpoint, { min: 5, max: constants.repInterval.MINUTES_5, change: 0.00005 }); // 50 ppm change }, exposes: [e.co2(), e.battery(), e.humidity(), e.temperature()], }, { zigbeeModel: ['RouteLight-EF-3.0'], model: 'HS2RNL', vendor: 'HEIMAN', description: 'Smart repeater & night light', fromZigbee: [fromZigbee_1.default.on_off, fromZigbee_1.default.battery], toZigbee: [toZigbee_1.default.on_off], configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg', 'genOnOff', 'genLevelCtrl']); await reporting.onOff(endpoint); // switch the night light on/off await reporting.batteryPercentageRemaining(endpoint); // internal backup battery in case of power outage }, exposes: [e.switch(), e.battery()], }, { zigbeeModel: ['PIR_TPV12'], model: 'PIR_TPV12', vendor: 'HEIMAN', description: 'Motion sensor', extend: [ (0, modernExtend_1.battery)({ voltageToPercentage: '3V_2500', voltage: true }), (0, modernExtend_1.iasZoneAlarm)({ zoneType: 'occupancy', zoneAttributes: ['alarm_1', 'tamper', 'battery_low'] }), ], }, ]; exports.default = definitions; module.exports = definitions; //# sourceMappingURL=heiman.js.map