zigbee-herdsman-converters
Version:
Collection of device converters to be used with zigbee-herdsman
196 lines • 10.5 kB
JavaScript
"use strict";
var __createBinding = (this && this.__createBinding) || (Object.create ? (function(o, m, k, k2) {
if (k2 === undefined) k2 = k;
var desc = Object.getOwnPropertyDescriptor(m, k);
if (!desc || ("get" in desc ? !m.__esModule : desc.writable || desc.configurable)) {
desc = { enumerable: true, get: function() { return m[k]; } };
}
Object.defineProperty(o, k2, desc);
}) : (function(o, m, k, k2) {
if (k2 === undefined) k2 = k;
o[k2] = m[k];
}));
var __setModuleDefault = (this && this.__setModuleDefault) || (Object.create ? (function(o, v) {
Object.defineProperty(o, "default", { enumerable: true, value: v });
}) : function(o, v) {
o["default"] = v;
});
var __importStar = (this && this.__importStar) || function (mod) {
if (mod && mod.__esModule) return mod;
var result = {};
if (mod != null) for (var k in mod) if (k !== "default" && Object.prototype.hasOwnProperty.call(mod, k)) __createBinding(result, mod, k);
__setModuleDefault(result, mod);
return result;
};
var __importDefault = (this && this.__importDefault) || function (mod) {
return (mod && mod.__esModule) ? mod : { "default": mod };
};
Object.defineProperty(exports, "__esModule", { value: true });
const exposes = __importStar(require("../lib/exposes"));
const fromZigbee_1 = __importDefault(require("../converters/fromZigbee"));
const toZigbee_1 = __importDefault(require("../converters/toZigbee"));
const constants = __importStar(require("../lib/constants"));
const reporting = __importStar(require("../lib/reporting"));
const modernExtend_1 = require("../lib/modernExtend");
const ea = exposes.access;
const e = exposes.presets;
const definitions = [
{
zigbeeModel: ['ElkoDimmerZHA'],
model: '316GLEDRF',
vendor: 'ELKO',
description: 'ZigBee in-wall smart dimmer',
extend: [(0, modernExtend_1.light)({ configureReporting: true })],
meta: { disableDefaultResponse: true },
},
{
zigbeeModel: ['ElkoDimmerRemoteZHA'],
model: 'EKO05806',
vendor: 'ELKO',
description: 'Elko ESH 316 Endevender RF',
fromZigbee: [fromZigbee_1.default.command_toggle, fromZigbee_1.default.command_step],
toZigbee: [],
exposes: [e.action(['toggle', 'brightness_step_up', 'brightness_step_down'])],
configure: async (device, coordinatorEndpoint) => {
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff', 'genLevelCtrl']);
await reporting.onOff(endpoint);
},
},
{
zigbeeModel: ['Super TR'],
model: '4523430',
vendor: 'ELKO',
description: 'ESH Plus Super TR RF PH',
fromZigbee: [fromZigbee_1.default.elko_thermostat, fromZigbee_1.default.thermostat],
toZigbee: [toZigbee_1.default.thermostat_occupied_heating_setpoint, toZigbee_1.default.thermostat_occupied_heating_setpoint, toZigbee_1.default.elko_load,
toZigbee_1.default.elko_display_text, toZigbee_1.default.elko_power_status, toZigbee_1.default.elko_external_temp, toZigbee_1.default.elko_mean_power, toZigbee_1.default.elko_child_lock, toZigbee_1.default.elko_frost_guard,
toZigbee_1.default.elko_relay_state, toZigbee_1.default.elko_sensor_mode, toZigbee_1.default.elko_local_temperature_calibration, toZigbee_1.default.elko_max_floor_temp,
toZigbee_1.default.elko_regulator_mode, toZigbee_1.default.elko_regulator_time, toZigbee_1.default.elko_night_switching],
exposes: [e.text('display_text', ea.ALL).withDescription('Displayed text on thermostat display (zone). Max 14 characters'),
e.numeric('load', ea.ALL).withUnit('W')
.withDescription('Load in W when heating is on (between 0-2300 W). The thermostat uses the value as input to the ' +
'mean_power calculation.')
.withValueMin(0).withValueMax(2300),
e.binary('regulator_mode', ea.ALL, 'regulator', 'thermostat')
.withDescription('Device in regulator or thermostat mode.'),
e.numeric('regulator_time', ea.ALL).withUnit('min')
.withValueMin(5).withValueMax(20).withDescription('When device is in regulator mode this controls the time between each ' +
'in/out connection. When device is in thermostat mode this controls the time between each in/out switch when measured ' +
'temperature is within +-0.5 °C set temperature. Choose a long time for (slow) concrete floors and a short time for ' +
'(quick) wooden floors.'),
e.climate().withSetpoint('occupied_heating_setpoint', 5, 50, 1)
.withLocalTemperature(ea.STATE)
.withLocalTemperatureCalibration()
.withSystemMode(['off', 'heat']).withRunningState(['idle', 'heat']),
e.temperature_sensor_select(['air', 'floor', 'supervisor_floor']),
e.numeric('floor_temp', ea.STATE_GET).withUnit('°C')
.withDescription('Current temperature measured from the floor sensor'),
e.numeric('max_floor_temp', ea.ALL).withUnit('°C')
.withDescription('Set max floor temperature (between 20-35 °C) when "supervisor_floor" is set')
.withValueMin(20).withValueMax(35),
e.numeric('mean_power', ea.STATE_GET).withUnit('W')
.withDescription('Reports average power usage last 10 minutes'),
e.binary('child_lock', ea.ALL, 'lock', 'unlock')
.withDescription('Enables/disables physical input on the device'),
e.binary('frost_guard', ea.ALL, 'on', 'off')
.withDescription('When frost guard is ON, it is activated when the thermostat is switched OFF with the ON/OFF button.' +
'At the same time, the display will fade and the text "Frostsikring x °C" appears in the display and remains until the ' +
'thermostat is switched on again.'),
e.binary('night_switching', ea.ALL, 'on', 'off')
.withDescription('Turn on or off night setting.'),
],
configure: async (device, coordinatorEndpoint) => {
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ['hvacThermostat', 'genBasic', 'genIdentify']);
// standard ZCL attributes
await reporting.thermostatTemperature(endpoint);
await reporting.thermostatOccupiedHeatingSetpoint(endpoint);
// ELKO attributes
// Load value
await endpoint.configureReporting('hvacThermostat', [{
attribute: 'elkoLoad',
minimumReportInterval: 0,
maximumReportInterval: constants.repInterval.HOUR,
reportableChange: 1,
}]);
// Power status
await endpoint.configureReporting('hvacThermostat', [{
attribute: 'elkoPowerStatus',
minimumReportInterval: 0,
maximumReportInterval: constants.repInterval.HOUR,
reportableChange: null,
}]);
// Power consumption
await endpoint.configureReporting('hvacThermostat', [{
attribute: 'elkoMeanPower',
minimumReportInterval: 0,
maximumReportInterval: constants.repInterval.HOUR,
reportableChange: 5,
}]);
// External temp sensor (floor)
await endpoint.configureReporting('hvacThermostat', [{
attribute: 'elkoExternalTemp',
minimumReportInterval: 0,
maximumReportInterval: constants.repInterval.HOUR,
reportableChange: 10,
}]);
// Child lock active/inactive
await endpoint.configureReporting('hvacThermostat', [{
attribute: 'elkoChildLock',
minimumReportInterval: 0,
maximumReportInterval: constants.repInterval.HOUR,
reportableChange: null,
}]);
// Night switching
await endpoint.configureReporting('hvacThermostat', [{
attribute: 'elkoNightSwitching',
minimumReportInterval: 0,
maximumReportInterval: constants.repInterval.HOUR,
reportableChange: null,
}]);
// Frost guard
await endpoint.configureReporting('hvacThermostat', [{
attribute: 'elkoFrostGuard',
minimumReportInterval: 0,
maximumReportInterval: constants.repInterval.HOUR,
reportableChange: null,
}]);
// Heating active/inactive
await endpoint.configureReporting('hvacThermostat', [{
attribute: 'elkoRelayState',
minimumReportInterval: 0,
maximumReportInterval: constants.repInterval.HOUR,
reportableChange: null,
}]);
// Max floor temp
await endpoint.configureReporting('hvacThermostat', [{
attribute: 'elkoMaxFloorTemp',
minimumReportInterval: 0,
maximumReportInterval: constants.repInterval.HOUR,
reportableChange: 1,
}]);
// Regulator mode
await endpoint.configureReporting('hvacThermostat', [{
attribute: 'elkoRegulatorMode',
minimumReportInterval: 0,
maximumReportInterval: constants.repInterval.HOUR,
reportableChange: null,
}]);
// Regulator time
await endpoint.configureReporting('hvacThermostat', [{
attribute: 'elkoRegulatorTime',
minimumReportInterval: 0,
maximumReportInterval: constants.repInterval.HOUR,
reportableChange: 1,
}]);
// Trigger read
await endpoint.read('hvacThermostat', ['elkoDisplayText', 'elkoSensor']);
device.powerSource = 'Mains (single phase)';
device.save();
},
},
];
exports.default = definitions;