const exposes = require('../lib/exposes');
const fz = {...require('../converters/fromZigbee'), legacy: require('../lib/legacy').fromZigbee};
const tz = require('../converters/toZigbee');
const constants = require('../lib/constants');
const reporting = require('../lib/reporting');
const extend = require('../lib/extend');
const e = exposes.presets;
const ea = exposes.access;
module.exports = [
{
zigbeeModel: ['TH1123ZB'],
model: 'TH1123ZB',
vendor: 'Sinope',
description: 'Zigbee line volt thermostat',
fromZigbee: [fz.legacy.sinope_thermostat_att_report, fz.legacy.hvac_user_interface, fz.electrical_measurement, fz.metering,
fz.ignore_temperature_report, fz.legacy.sinope_thermostat_state],
toZigbee: [tz.thermostat_local_temperature, tz.thermostat_occupied_heating_setpoint, tz.thermostat_unoccupied_heating_setpoint,
tz.thermostat_temperature_display_mode, tz.thermostat_keypad_lockout, tz.thermostat_system_mode, tz.thermostat_running_state,
tz.sinope_thermostat_occupancy, tz.sinope_thermostat_backlight_autodim_param, tz.sinope_thermostat_time,
tz.sinope_thermostat_enable_outdoor_temperature, tz.sinope_thermostat_outdoor_temperature, tz.sinope_time_format],
exposes: [e.local_temperature(), e.keypad_lockout(), e.power(), e.current(), e.voltage(), e.energy(),
exposes.climate().withSetpoint('occupied_heating_setpoint', 7, 30, 0.5).withLocalTemperature()
.withSystemMode(['off', 'auto', 'heat']).withRunningState(['idle', 'heat']),
exposes.enum('backlight_auto_dim', ea.SET, ['on demand', 'sensing']).withDescription('Control backlight dimming behavior')],
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(1);
const binds = ['genBasic', 'genIdentify', 'genGroups', 'hvacThermostat', 'hvacUserInterfaceCfg', 'msTemperatureMeasurement',
'haElectricalMeasurement', 'seMetering', 'manuSpecificSinope'];
await reporting.bind(endpoint, coordinatorEndpoint, binds);
await reporting.thermostatTemperature(endpoint, {min: 10, max: 300, change: 20});
await reporting.thermostatPIHeatingDemand(endpoint, {min: 10, max: 301, change: 5});
await reporting.thermostatOccupiedHeatingSetpoint(endpoint, {min: 1, max: 302, change: 50});
await reporting.thermostatSystemMode(endpoint, {min: 1, max: 0});
await reporting.readMeteringMultiplierDivisor(endpoint);
await reporting.currentSummDelivered(endpoint, {min: 10, max: 303, change: [1, 1]});
try {
await reporting.instantaneousDemand(endpoint, {min: 10, max: 304, change: 1});
} catch (error) {/* Do nothing*/}
await reporting.readEletricalMeasurementMultiplierDivisors(endpoint);
try {
await reporting.activePower(endpoint, {min: 10, max: 305, change: 1});
} catch (error) {/* Do nothing*/}
try {
await reporting.rmsCurrent(endpoint, {min: 10, max: 306, change: 100}); // divider 1000: 0.1Arms
} catch (error) {/* Do nothing*/}
try {
await reporting.rmsVoltage(endpoint, {min: 10, max: 307, change: 5}); // divider 10: 0.5Vrms
} catch (error) {/* Do nothing*/}
// Disable default reporting
await reporting.temperature(endpoint, {min: 1, max: 0xFFFF});
await endpoint.configureReporting('msTemperatureMeasurement', [{
attribute: 'tolerance', minimumReportInterval: 1, maximumReportInterval: 0xFFFF, reportableChange: 1}]);
},
},
{
zigbeeModel: ['TH1124ZB'],
model: 'TH1124ZB',
vendor: 'Sinope',
description: 'Zigbee line volt thermostat',
fromZigbee: [fz.legacy.thermostat_att_report, fz.legacy.hvac_user_interface, fz.electrical_measurement, fz.metering,
fz.ignore_temperature_report, fz.legacy.sinope_thermostat_state],
toZigbee: [tz.thermostat_local_temperature, tz.thermostat_occupied_heating_setpoint, tz.thermostat_unoccupied_heating_setpoint,
tz.thermostat_temperature_display_mode, tz.thermostat_keypad_lockout, tz.thermostat_system_mode, tz.thermostat_running_state,
tz.sinope_thermostat_occupancy, tz.sinope_thermostat_backlight_autodim_param, tz.sinope_thermostat_time,
tz.sinope_thermostat_enable_outdoor_temperature, tz.sinope_thermostat_outdoor_temperature, tz.sinope_time_format],
exposes: [e.local_temperature(), e.keypad_lockout(), e.power(), e.current(), e.voltage(), e.energy(),
exposes.climate().withSetpoint('occupied_heating_setpoint', 7, 30, 0.5).withLocalTemperature()
.withSystemMode(['off', 'auto', 'heat']).withRunningState(['idle', 'heat']).withPiHeatingDemand(),
exposes.enum('backlight_auto_dim', ea.SET, ['on demand', 'sensing']).withDescription('Control backlight dimming behavior')],
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(1);
const binds = ['genBasic', 'genIdentify', 'genGroups', 'hvacThermostat', 'hvacUserInterfaceCfg', 'msTemperatureMeasurement',
'haElectricalMeasurement', 'seMetering', 'manuSpecificSinope'];
await reporting.bind(endpoint, coordinatorEndpoint, binds);
await reporting.thermostatTemperature(endpoint, {min: 10, max: 300, change: 20});
await reporting.thermostatPIHeatingDemand(endpoint, {min: 10, max: 301, change: 5});
await reporting.thermostatOccupiedHeatingSetpoint(endpoint, {min: 1, max: 302, change: 50});
await reporting.readMeteringMultiplierDivisor(endpoint);
await reporting.currentSummDelivered(endpoint, {min: 10, max: 303, change: [1, 1]});
try {
await reporting.instantaneousDemand(endpoint, {min: 10, max: 304, change: 1});
} catch (error) {/* Do nothing*/}
await reporting.readEletricalMeasurementMultiplierDivisors(endpoint);
try {
await reporting.activePower(endpoint, {min: 10, max: 305, change: 1});
} catch (error) {/* Do nothing*/}
try {
await reporting.rmsCurrent(endpoint, {min: 10, max: 306, change: 100}); // divider 1000: 0.1Arms
} catch (error) {/* Do nothing*/}
try {
await reporting.rmsVoltage(endpoint, {min: 10, max: 307, change: 5}); // divider 10: 0.5Vrms
} catch (error) {/* Do nothing*/}
try {
await reporting.thermostatKeypadLockMode(endpoint, {min: 1, max: 0});
} catch (error) {
// Not all support this: https://github.com/Koenkk/zigbee2mqtt/issues/3760
}
// Disable default reporting
await reporting.temperature(endpoint, {min: 1, max: 0xFFFF});
await endpoint.configureReporting('msTemperatureMeasurement', [{
attribute: 'tolerance', minimumReportInterval: 1, maximumReportInterval: 0xFFFF, reportableChange: 1}]);
},
},
{
zigbeeModel: ['TH1300ZB'],
model: 'TH1300ZB',
vendor: 'Sinope',
description: 'Zigbee smart floor heating thermostat',
fromZigbee: [fz.legacy.thermostat_att_report, fz.legacy.hvac_user_interface, fz.ignore_temperature_report,
fz.legacy.sinope_thermostat_state, fz.sinope_TH1300ZB_specific],
toZigbee: [tz.thermostat_local_temperature, tz.thermostat_occupied_heating_setpoint, tz.thermostat_unoccupied_heating_setpoint,
tz.thermostat_temperature_display_mode, tz.thermostat_keypad_lockout, tz.thermostat_system_mode, tz.thermostat_running_state,
tz.sinope_thermostat_occupancy, tz.sinope_thermostat_backlight_autodim_param, tz.sinope_thermostat_time,
tz.sinope_thermostat_enable_outdoor_temperature, tz.sinope_thermostat_outdoor_temperature, tz.sinope_floor_control_mode,
tz.sinope_ambiant_max_heat_setpoint, tz.sinope_floor_min_heat_setpoint, tz.sinope_floor_max_heat_setpoint,
tz.sinope_temperature_sensor, tz.sinope_time_format],
exposes: [e.local_temperature(), e.keypad_lockout(),
exposes.climate().withSetpoint('occupied_heating_setpoint', 7, 30, 0.5).withLocalTemperature()
.withSystemMode(['off', 'auto', 'heat']).withRunningState(['idle', 'heat']).withPiHeatingDemand(),
exposes.enum('backlight_auto_dim', ea.SET, ['on demand', 'sensing']).withDescription('Control backlight dimming behavior')],
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(1);
const binds = ['genBasic', 'genIdentify', 'genGroups', 'hvacThermostat', 'hvacUserInterfaceCfg',
'msTemperatureMeasurement', 'manuSpecificSinope'];
await reporting.bind(endpoint, coordinatorEndpoint, binds);
await reporting.thermostatTemperature(endpoint, {min: 10, max: 300, change: 20});
await reporting.thermostatPIHeatingDemand(endpoint, {min: 10, max: 301, change: 5});
await reporting.thermostatOccupiedHeatingSetpoint(endpoint, {min: 1, max: 302, change: 50});
try {
await reporting.thermostatKeypadLockMode(endpoint, {min: 1, max: 0});
} catch (error) {
// Not all support this: https://github.com/Koenkk/zigbee2mqtt/issues/3760
}
await endpoint.configureReporting('manuSpecificSinope', [{attribute: 'GFCiStatus', minimumReportInterval: 1,
maximumReportInterval: constants.repInterval.HOUR, reportableChange: 1}]);
await endpoint.configureReporting('manuSpecificSinope', [{attribute: 'floorLimitStatus',
minimumReportInterval: 1, maximumReportInterval: constants.repInterval.HOUR, reportableChange: 1}]);
await reporting.temperature(endpoint, {min: 1, max: 0xFFFF}); // disable reporting
},
},
{
zigbeeModel: ['TH1400ZB'],
model: 'TH1400ZB',
vendor: 'Sinope',
description: 'Zigbee low volt thermostat',
fromZigbee: [fz.legacy.sinope_thermostat_att_report],
toZigbee: [tz.thermostat_local_temperature, tz.thermostat_occupied_heating_setpoint, tz.thermostat_temperature_display_mode,
tz.thermostat_keypad_lockout, tz.thermostat_system_mode, tz.thermostat_running_state,
tz.sinope_thermostat_backlight_autodim_param, tz.sinope_thermostat_time, tz.sinope_thermostat_enable_outdoor_temperature,
tz.sinope_thermostat_outdoor_temperature],
exposes: [exposes.climate().withSetpoint('occupied_heating_setpoint', 7, 30, 1).withLocalTemperature()
.withSystemMode(['off', 'auto', 'heat']).withRunningState(['idle', 'heat']), exposes.enum('backlight_auto_dim',
ea.SET, ['on demand', 'sensing']).withDescription('Control backlight dimming behavior')],
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(1);
const binds = ['genBasic', 'genIdentify', 'genGroups', 'hvacThermostat', 'hvacUserInterfaceCfg', 'msTemperatureMeasurement'];
await reporting.bind(endpoint, coordinatorEndpoint, binds);
await reporting.thermostatTemperature(endpoint);
await reporting.thermostatOccupiedHeatingSetpoint(endpoint);
await reporting.thermostatPIHeatingDemand(endpoint);
},
},
{
zigbeeModel: ['TH1500ZB'],
model: 'TH1500ZB',
vendor: 'Sinope',
description: 'Zigbee dual pole line volt thermostat',
fromZigbee: [fz.legacy.thermostat_att_report],
toZigbee: [tz.thermostat_local_temperature, tz.thermostat_occupied_heating_setpoint, tz.thermostat_unoccupied_heating_setpoint,
tz.thermostat_temperature_display_mode, tz.thermostat_keypad_lockout, tz.thermostat_system_mode, tz.thermostat_running_state,
tz.sinope_thermostat_occupancy, tz.sinope_thermostat_backlight_autodim_param, tz.sinope_thermostat_time,
tz.sinope_thermostat_enable_outdoor_temperature, tz.sinope_thermostat_outdoor_temperature],
exposes: [exposes.climate().withSetpoint('occupied_heating_setpoint', 7, 30, 1).withLocalTemperature()
.withSystemMode(['off', 'auto', 'heat']).withRunningState(['idle', 'heat']).withPiHeatingDemand(), exposes.enum(
'backlight_auto_dim', ea.SET, ['on demand', 'sensing']).withDescription('Control backlight dimming behavior')],
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(1);
const binds = ['genBasic', 'genIdentify', 'genGroups', 'hvacThermostat', 'hvacUserInterfaceCfg', 'msTemperatureMeasurement'];
await reporting.bind(endpoint, coordinatorEndpoint, binds);
await reporting.thermostatTemperature(endpoint);
await reporting.thermostatOccupiedHeatingSetpoint(endpoint);
await reporting.thermostatPIHeatingDemand(endpoint);
},
},
{
zigbeeModel: ['SW2500ZB'],
model: 'SW2500ZB',
vendor: 'Sinope',
description: 'Zigbee smart light switch',
extend: extend.switch(),
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff']);
await reporting.onOff(endpoint);
},
},
{
zigbeeModel: ['SP2600ZB'],
model: 'SP2600ZB',
vendor: 'Sinope',
description: 'Zigbee smart plug',
extend: extend.switch(),
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff']);
await reporting.onOff(endpoint);
},
},
{
zigbeeModel: ['DM2500ZB'],
model: 'DM2500ZB',
vendor: 'Sinope',
description: 'Zigbee smart dimmer',
extend: extend.light_onoff_brightness({noConfigure: true}),
configure: async (device, coordinatorEndpoint, logger) => {
await extend.light_onoff_brightness().configure(device, coordinatorEndpoint, logger);
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff', 'genLevelCtrl']);
await reporting.onOff(endpoint);
await reporting.brightness(endpoint);
},
},
{
zigbeeModel: ['RM3250ZB'],
model: 'RM3250ZB',
vendor: 'Sinope',
description: '50A Smart electrical load controller',
fromZigbee: [fz.on_off, fz.electrical_measurement, fz.metering],
toZigbee: [tz.on_off],
configure: async (device, coordinatorEndpoint) => {
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff', 'haElectricalMeasurement', 'seMetering']);
await reporting.onOff(endpoint);
await reporting.readEletricalMeasurementMultiplierDivisors(endpoint);
await reporting.activePower(endpoint);
await reporting.rmsCurrent(endpoint);
await reporting.rmsVoltage(endpoint);
await reporting.readMeteringMultiplierDivisor(endpoint);
await reporting.currentSummDelivered(endpoint);
},
exposes: [e.switch(), e.power(), e.current(), e.voltage(), e.energy()],
},
{
zigbeeModel: ['WL4200'],
model: 'WL4200',
vendor: 'Sinope',
description: 'Zigbee smart water leak detector',
fromZigbee: [fz.ias_water_leak_alarm_1],
toZigbee: [],
exposes: [e.water_leak(), e.battery_low(), e.tamper()],
},
];