module.exports = [
{
zigbeeModel: ['SM308'],
model: 'SM308',
vendor: 'Samotech',
description: 'Zigbee AC in wall switch',
extend: extend.switch(),
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ['genBasic', 'genIdentify', 'genOnOff']);
},
},
{
zigbeeModel: ['SM309'],
model: 'SM309',
vendor: 'Samotech',
description: 'ZigBee dimmer 400W',
extend: extend.light_onoff_brightness({noConfigure: true}),
configure: async (device, coordinatorEndpoint, logger) => {
await extend.light_onoff_brightness().configure(device, coordinatorEndpoint, logger);
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff', 'genLevelCtrl']);
await reporting.onOff(endpoint);
},
},
{
fingerprint: [{modelID: 'Dimmer-Switch-ZB3.0', manufacturerName: 'Samotech'}],
model: 'SM323',
vendor: 'Samotech',
description: 'ZigBee retrofit dimmer 250W',
extend: extend.light_onoff_brightness({noConfigure: true}),
configure: async (device, coordinatorEndpoint, logger) => {
await extend.light_onoff_brightness().configure(device, coordinatorEndpoint, logger);
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff', 'genLevelCtrl']);
await reporting.onOff(endpoint);
await reporting.brightness(endpoint);
},
},
];