const exposes = require('../lib/exposes');
const fz = {...require('../converters/fromZigbee'), legacy: require('../lib/legacy').fromZigbee};
const reporting = require('../lib/reporting');
const e = exposes.presets;
module.exports = [
{
zigbeeModel: ['RFDL-ZB', 'RFDL-ZB-EU', 'RFDL-ZB-H', 'RFDL-ZB-K', 'RFDL-ZB-CHI', 'RFDL-ZB-MS', 'RFDL-ZB-ES', 'RFPR-ZB',
'RFPR-ZB-EU', 'RFPR-ZB-CHI', 'RFPR-ZB-ES', 'RFPR-ZB-MS'],
model: 'RADON TriTech ZB',
vendor: 'Bosch',
description: 'Wireless motion detector',
fromZigbee: [fz.temperature, fz.battery, fz.ias_occupancy_alarm_1],
toZigbee: [],
meta: {battery: {voltageToPercentage: '3V_2500'}},
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ['msTemperatureMeasurement', 'genPowerCfg']);
await reporting.temperature(endpoint);
await reporting.batteryVoltage(endpoint);
},
exposes: [e.temperature(), e.battery(), e.occupancy(), e.battery_low(), e.tamper()],
},
{
zigbeeModel: ['ISW-ZPR1-WP13'],
model: 'ISW-ZPR1-WP13',
vendor: 'Bosch',
description: 'Motion sensor',
fromZigbee: [fz.temperature, fz.battery, fz.ias_occupancy_alarm_1, fz.ignore_iaszone_report],
toZigbee: [],
meta: {battery: {voltageToPercentage: '3V_2500'}},
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(5);
await reporting.bind(endpoint, coordinatorEndpoint, ['msTemperatureMeasurement', 'genPowerCfg']);
await reporting.temperature(endpoint);
await reporting.batteryVoltage(endpoint);
},
exposes: [e.temperature(), e.battery(), e.occupancy(), e.battery_low(), e.tamper()],
},
];