yoctolib-esm
Version:
Yoctopuce library for TypeScript/JavaScript, as an ECMAScript 2015 module
216 lines (215 loc) • 9.83 kB
TypeScript
/*********************************************************************
*
* $Id: svn_id $
*
* Implements the high-level API for VoltageOutput functions
*
* - - - - - - - - - License information: - - - - - - - - -
*
* Copyright (C) 2011 and beyond by Yoctopuce Sarl, Switzerland.
*
* Yoctopuce Sarl (hereafter Licensor) grants to you a perpetual
* non-exclusive license to use, modify, copy and integrate this
* file into your software for the sole purpose of interfacing
* with Yoctopuce products.
*
* You may reproduce and distribute copies of this file in
* source or object form, as long as the sole purpose of this
* code is to interface with Yoctopuce products. You must retain
* this notice in the distributed source file.
*
* You should refer to Yoctopuce General Terms and Conditions
* for additional information regarding your rights and
* obligations.
*
* THE SOFTWARE AND DOCUMENTATION ARE PROVIDED 'AS IS' WITHOUT
* WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING
* WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY, FITNESS
* FOR A PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT. IN NO
* EVENT SHALL LICENSOR BE LIABLE FOR ANY INCIDENTAL, SPECIAL,
* INDIRECT OR CONSEQUENTIAL DAMAGES, LOST PROFITS OR LOST DATA,
* COST OF PROCUREMENT OF SUBSTITUTE GOODS, TECHNOLOGY OR
* SERVICES, ANY CLAIMS BY THIRD PARTIES (INCLUDING BUT NOT
* LIMITED TO ANY DEFENSE THEREOF), ANY CLAIMS FOR INDEMNITY OR
* CONTRIBUTION, OR OTHER SIMILAR COSTS, WHETHER ASSERTED ON THE
* BASIS OF CONTRACT, TORT (INCLUDING NEGLIGENCE), BREACH OF
* WARRANTY, OR OTHERWISE.
*
*********************************************************************/
import { YAPIContext, YFunction } from './yocto_api.js';
/**
* YVoltageOutput Class: voltage output control interface, available for instance in the Yocto-0-10V-Tx
*
* The YVoltageOutput class allows you to drive a voltage output.
*/
export declare class YVoltageOutput extends YFunction {
_className: string;
_currentVoltage: number;
_voltageTransition: string;
_voltageAtStartUp: number;
_valueCallbackVoltageOutput: YVoltageOutput.ValueCallback | null;
readonly CURRENTVOLTAGE_INVALID: number;
readonly VOLTAGETRANSITION_INVALID: string;
readonly VOLTAGEATSTARTUP_INVALID: number;
static readonly CURRENTVOLTAGE_INVALID: number;
static readonly VOLTAGETRANSITION_INVALID: string;
static readonly VOLTAGEATSTARTUP_INVALID: number;
constructor(yapi: YAPIContext, func: string);
imm_parseAttr(name: string, val: any): number;
/**
* Changes the output voltage, in V. Valid range is from 0 to 10V.
*
* @param newval : a floating point number corresponding to the output voltage, in V
*
* @return YAPI.SUCCESS if the call succeeds.
*
* On failure, throws an exception or returns a negative error code.
*/
set_currentVoltage(newval: number): Promise<number>;
/**
* Returns the output voltage set point, in V.
*
* @return a floating point number corresponding to the output voltage set point, in V
*
* On failure, throws an exception or returns YVoltageOutput.CURRENTVOLTAGE_INVALID.
*/
get_currentVoltage(): Promise<number>;
get_voltageTransition(): Promise<string>;
set_voltageTransition(newval: string): Promise<number>;
/**
* Changes the output voltage at device start up. Remember to call the matching
* module saveToFlash() method, otherwise this call has no effect.
*
* @param newval : a floating point number corresponding to the output voltage at device start up
*
* @return YAPI.SUCCESS if the call succeeds.
*
* On failure, throws an exception or returns a negative error code.
*/
set_voltageAtStartUp(newval: number): Promise<number>;
/**
* Returns the selected voltage output at device startup, in V.
*
* @return a floating point number corresponding to the selected voltage output at device startup, in V
*
* On failure, throws an exception or returns YVoltageOutput.VOLTAGEATSTARTUP_INVALID.
*/
get_voltageAtStartUp(): Promise<number>;
/**
* Retrieves a voltage output for a given identifier.
* The identifier can be specified using several formats:
*
* - FunctionLogicalName
* - ModuleSerialNumber.FunctionIdentifier
* - ModuleSerialNumber.FunctionLogicalName
* - ModuleLogicalName.FunctionIdentifier
* - ModuleLogicalName.FunctionLogicalName
*
*
* This function does not require that the voltage output is online at the time
* it is invoked. The returned object is nevertheless valid.
* Use the method YVoltageOutput.isOnline() to test if the voltage output is
* indeed online at a given time. In case of ambiguity when looking for
* a voltage output by logical name, no error is notified: the first instance
* found is returned. The search is performed first by hardware name,
* then by logical name.
*
* If a call to this object's is_online() method returns FALSE although
* you are certain that the matching device is plugged, make sure that you did
* call registerHub() at application initialization time.
*
* @param func : a string that uniquely characterizes the voltage output, for instance
* TX010V01.voltageOutput1.
*
* @return a YVoltageOutput object allowing you to drive the voltage output.
*/
static FindVoltageOutput(func: string): YVoltageOutput;
/**
* Retrieves a voltage output for a given identifier in a YAPI context.
* The identifier can be specified using several formats:
*
* - FunctionLogicalName
* - ModuleSerialNumber.FunctionIdentifier
* - ModuleSerialNumber.FunctionLogicalName
* - ModuleLogicalName.FunctionIdentifier
* - ModuleLogicalName.FunctionLogicalName
*
*
* This function does not require that the voltage output is online at the time
* it is invoked. The returned object is nevertheless valid.
* Use the method YVoltageOutput.isOnline() to test if the voltage output is
* indeed online at a given time. In case of ambiguity when looking for
* a voltage output by logical name, no error is notified: the first instance
* found is returned. The search is performed first by hardware name,
* then by logical name.
*
* @param yctx : a YAPI context
* @param func : a string that uniquely characterizes the voltage output, for instance
* TX010V01.voltageOutput1.
*
* @return a YVoltageOutput object allowing you to drive the voltage output.
*/
static FindVoltageOutputInContext(yctx: YAPIContext, func: string): YVoltageOutput;
/**
* Registers the callback function that is invoked on every change of advertised value.
* The callback is invoked only during the execution of ySleep or yHandleEvents.
* This provides control over the time when the callback is triggered. For good responsiveness, remember to call
* one of these two functions periodically. To unregister a callback, pass a null pointer as argument.
*
* @param callback : the callback function to call, or a null pointer. The callback function should take two
* arguments: the function object of which the value has changed, and the character string describing
* the new advertised value.
* @noreturn
*/
registerValueCallback(callback: YVoltageOutput.ValueCallback | null): Promise<number>;
_invokeValueCallback(value: string): Promise<number>;
/**
* Performs a smooth transition of output voltage. Any explicit voltage
* change cancels any ongoing transition process.
*
* @param V_target : new output voltage value at the end of the transition
* (floating-point number, representing the end voltage in V)
* @param ms_duration : total duration of the transition, in milliseconds
*
* @return YAPI.SUCCESS when the call succeeds.
*/
voltageMove(V_target: number, ms_duration: number): Promise<number>;
/**
* Continues the enumeration of voltage outputs started using yFirstVoltageOutput().
* Caution: You can't make any assumption about the returned voltage outputs order.
* If you want to find a specific a voltage output, use VoltageOutput.findVoltageOutput()
* and a hardwareID or a logical name.
*
* @return a pointer to a YVoltageOutput object, corresponding to
* a voltage output currently online, or a null pointer
* if there are no more voltage outputs to enumerate.
*/
nextVoltageOutput(): YVoltageOutput | null;
/**
* Starts the enumeration of voltage outputs currently accessible.
* Use the method YVoltageOutput.nextVoltageOutput() to iterate on
* next voltage outputs.
*
* @return a pointer to a YVoltageOutput object, corresponding to
* the first voltage output currently online, or a null pointer
* if there are none.
*/
static FirstVoltageOutput(): YVoltageOutput | null;
/**
* Starts the enumeration of voltage outputs currently accessible.
* Use the method YVoltageOutput.nextVoltageOutput() to iterate on
* next voltage outputs.
*
* @param yctx : a YAPI context.
*
* @return a pointer to a YVoltageOutput object, corresponding to
* the first voltage output currently online, or a null pointer
* if there are none.
*/
static FirstVoltageOutputInContext(yctx: YAPIContext): YVoltageOutput | null;
}
export declare namespace YVoltageOutput {
interface ValueCallback {