yoctolib-esm
Version:
Yoctopuce library for TypeScript/JavaScript, as an ECMAScript 2015 module
258 lines (257 loc) • 12.5 kB
TypeScript
/*********************************************************************
*
* $Id: svn_id $
*
* Implements the high-level API for CarbonDioxide functions
*
* - - - - - - - - - License information: - - - - - - - - -
*
* Copyright (C) 2011 and beyond by Yoctopuce Sarl, Switzerland.
*
* Yoctopuce Sarl (hereafter Licensor) grants to you a perpetual
* non-exclusive license to use, modify, copy and integrate this
* file into your software for the sole purpose of interfacing
* with Yoctopuce products.
*
* You may reproduce and distribute copies of this file in
* source or object form, as long as the sole purpose of this
* code is to interface with Yoctopuce products. You must retain
* this notice in the distributed source file.
*
* You should refer to Yoctopuce General Terms and Conditions
* for additional information regarding your rights and
* obligations.
*
* THE SOFTWARE AND DOCUMENTATION ARE PROVIDED 'AS IS' WITHOUT
* WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING
* WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY, FITNESS
* FOR A PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT. IN NO
* EVENT SHALL LICENSOR BE LIABLE FOR ANY INCIDENTAL, SPECIAL,
* INDIRECT OR CONSEQUENTIAL DAMAGES, LOST PROFITS OR LOST DATA,
* COST OF PROCUREMENT OF SUBSTITUTE GOODS, TECHNOLOGY OR
* SERVICES, ANY CLAIMS BY THIRD PARTIES (INCLUDING BUT NOT
* LIMITED TO ANY DEFENSE THEREOF), ANY CLAIMS FOR INDEMNITY OR
* CONTRIBUTION, OR OTHER SIMILAR COSTS, WHETHER ASSERTED ON THE
* BASIS OF CONTRACT, TORT (INCLUDING NEGLIGENCE), BREACH OF
* WARRANTY, OR OTHERWISE.
*
*********************************************************************/
import { YAPIContext, YSensor, YMeasure } from './yocto_api.js';
/**
* YCarbonDioxide Class: CO2 sensor control interface, available for instance in the Yocto-CO2-V2
*
* The YCarbonDioxide class allows you to read and configure Yoctopuce CO2 sensors.
* It inherits from YSensor class the core functions to read measures,
* to register callback functions, and to access the autonomous datalogger.
* This class adds the ability to perform manual calibration if required.
*/
export declare class YCarbonDioxide extends YSensor {
_className: string;
_abcPeriod: number;
_command: string;
_valueCallbackCarbonDioxide: YCarbonDioxide.ValueCallback | null;
_timedReportCallbackCarbonDioxide: YCarbonDioxide.TimedReportCallback | null;
readonly ABCPERIOD_INVALID: number;
readonly COMMAND_INVALID: string;
static readonly ABCPERIOD_INVALID: number;
static readonly COMMAND_INVALID: string;
constructor(yapi: YAPIContext, func: string);
imm_parseAttr(name: string, val: any): number;
/**
* Returns the Automatic Baseline Calibration period, in hours. A negative value
* means that automatic baseline calibration is disabled.
*
* @return an integer corresponding to the Automatic Baseline Calibration period, in hours
*
* On failure, throws an exception or returns YCarbonDioxide.ABCPERIOD_INVALID.
*/
get_abcPeriod(): Promise<number>;
/**
* Changes Automatic Baseline Calibration period, in hours. If you need
* to disable automatic baseline calibration (for instance when using the
* sensor in an environment that is constantly above 400 ppm CO2), set the
* period to -1. For the Yocto-CO2-V2, the only possible values are 24 and -1.
* Remember to call the saveToFlash() method of the
* module if the modification must be kept.
*
* @param newval : an integer corresponding to Automatic Baseline Calibration period, in hours
*
* @return YAPI.SUCCESS if the call succeeds.
*
* On failure, throws an exception or returns a negative error code.
*/
set_abcPeriod(newval: number): Promise<number>;
get_command(): Promise<string>;
set_command(newval: string): Promise<number>;
/**
* Retrieves a CO2 sensor for a given identifier.
* The identifier can be specified using several formats:
*
* - FunctionLogicalName
* - ModuleSerialNumber.FunctionIdentifier
* - ModuleSerialNumber.FunctionLogicalName
* - ModuleLogicalName.FunctionIdentifier
* - ModuleLogicalName.FunctionLogicalName
*
*
* This function does not require that the CO2 sensor is online at the time
* it is invoked. The returned object is nevertheless valid.
* Use the method YCarbonDioxide.isOnline() to test if the CO2 sensor is
* indeed online at a given time. In case of ambiguity when looking for
* a CO2 sensor by logical name, no error is notified: the first instance
* found is returned. The search is performed first by hardware name,
* then by logical name.
*
* If a call to this object's is_online() method returns FALSE although
* you are certain that the matching device is plugged, make sure that you did
* call registerHub() at application initialization time.
*
* @param func : a string that uniquely characterizes the CO2 sensor, for instance
* YCO2MK02.carbonDioxide.
*
* @return a YCarbonDioxide object allowing you to drive the CO2 sensor.
*/
static FindCarbonDioxide(func: string): YCarbonDioxide;
/**
* Retrieves a CO2 sensor for a given identifier in a YAPI context.
* The identifier can be specified using several formats:
*
* - FunctionLogicalName
* - ModuleSerialNumber.FunctionIdentifier
* - ModuleSerialNumber.FunctionLogicalName
* - ModuleLogicalName.FunctionIdentifier
* - ModuleLogicalName.FunctionLogicalName
*
*
* This function does not require that the CO2 sensor is online at the time
* it is invoked. The returned object is nevertheless valid.
* Use the method YCarbonDioxide.isOnline() to test if the CO2 sensor is
* indeed online at a given time. In case of ambiguity when looking for
* a CO2 sensor by logical name, no error is notified: the first instance
* found is returned. The search is performed first by hardware name,
* then by logical name.
*
* @param yctx : a YAPI context
* @param func : a string that uniquely characterizes the CO2 sensor, for instance
* YCO2MK02.carbonDioxide.
*
* @return a YCarbonDioxide object allowing you to drive the CO2 sensor.
*/
static FindCarbonDioxideInContext(yctx: YAPIContext, func: string): YCarbonDioxide;
/**
* Registers the callback function that is invoked on every change of advertised value.
* The callback is invoked only during the execution of ySleep or yHandleEvents.
* This provides control over the time when the callback is triggered. For good responsiveness, remember to call
* one of these two functions periodically. To unregister a callback, pass a null pointer as argument.
*
* @param callback : the callback function to call, or a null pointer. The callback function should take two
* arguments: the function object of which the value has changed, and the character string describing
* the new advertised value.
* @noreturn
*/
registerValueCallback(callback: YCarbonDioxide.ValueCallback | null): Promise<number>;
_invokeValueCallback(value: string): Promise<number>;
/**
* Registers the callback function that is invoked on every periodic timed notification.
* The callback is invoked only during the execution of ySleep or yHandleEvents.
* This provides control over the time when the callback is triggered. For good responsiveness, remember to call
* one of these two functions periodically. To unregister a callback, pass a null pointer as argument.
*
* @param callback : the callback function to call, or a null pointer. The callback function should take two
* arguments: the function object of which the value has changed, and an YMeasure object describing
* the new advertised value.
* @noreturn
*/
registerTimedReportCallback(callback: YCarbonDioxide.TimedReportCallback | null): Promise<number>;
_invokeTimedReportCallback(value: YMeasure): Promise<number>;
/**
* Triggers a forced calibration of the sensor at a given CO2 level, specified
* between 400ppm and 2000ppm. Before invoking this command, the sensor must
* have been maintained within the specified CO2 density during at least two
* minutes.
*
* @param refVal : reference CO2 density for the calibration
*
* @return YAPI.SUCCESS if the call succeeds.
*
* On failure, throws an exception or returns a negative error code.
*/
triggerForcedCalibration(refVal: number): Promise<number>;
/**
* Triggers a baseline calibration at standard CO2 ambiant level (400ppm).
* It is normally not necessary to manually calibrate the sensor, because
* the built-in automatic baseline calibration procedure will automatically
* fix any long-term drift based on the lowest level of CO2 observed over the
* automatic calibration period. However, if automatic baseline calibration
* is disabled, you may want to manually trigger a calibration from time to
* time. Before starting a baseline calibration, make sure to put the sensor
* in a standard environment (e.g. outside in fresh air) at around 400 ppm
* for at least two minutes.
*
* @return YAPI.SUCCESS if the call succeeds.
*
* On failure, throws an exception or returns a negative error code.
*/
triggerBaselineCalibration(): Promise<number>;
triggetBaselineCalibration(): Promise<number>;
/**
* Triggers a zero calibration of the sensor on carbon dioxide-free air -
* for use with first generation Yocto-CO2 only.
* It is normally not necessary to manually calibrate the sensor, because
* the built-in automatic baseline calibration procedure will automatically
* fix any long-term drift based on the lowest level of CO2 observed over the
* automatic calibration period. However, if you disable automatic baseline
* calibration, you may want to manually trigger a calibration from time to
* time. Before starting a zero calibration, you should circulate carbon
* dioxide-free air within the sensor for a minute or two, using a small pipe
* connected to the sensor. Please contact support@yoctopuce.com for more details
* on the zero calibration procedure.
*
* @return YAPI.SUCCESS if the call succeeds.
*
* On failure, throws an exception or returns a negative error code.
*/
triggerZeroCalibration(): Promise<number>;
triggetZeroCalibration(): Promise<number>;
/**
* Continues the enumeration of CO2 sensors started using yFirstCarbonDioxide().
* Caution: You can't make any assumption about the returned CO2 sensors order.
* If you want to find a specific a CO2 sensor, use CarbonDioxide.findCarbonDioxide()
* and a hardwareID or a logical name.
*
* @return a pointer to a YCarbonDioxide object, corresponding to
* a CO2 sensor currently online, or a null pointer
* if there are no more CO2 sensors to enumerate.
*/
nextCarbonDioxide(): YCarbonDioxide | null;
/**
* Starts the enumeration of CO2 sensors currently accessible.
* Use the method YCarbonDioxide.nextCarbonDioxide() to iterate on
* next CO2 sensors.
*
* @return a pointer to a YCarbonDioxide object, corresponding to
* the first CO2 sensor currently online, or a null pointer
* if there are none.
*/
static FirstCarbonDioxide(): YCarbonDioxide | null;
/**
* Starts the enumeration of CO2 sensors currently accessible.
* Use the method YCarbonDioxide.nextCarbonDioxide() to iterate on
* next CO2 sensors.
*
* @param yctx : a YAPI context.
*
* @return a pointer to a YCarbonDioxide object, corresponding to
* the first CO2 sensor currently online, or a null pointer
* if there are none.
*/
static FirstCarbonDioxideInContext(yctx: YAPIContext): YCarbonDioxide | null;
}
export declare namespace YCarbonDioxide {
interface ValueCallback {
(func: YCarbonDioxide, value: string): void;
}
interface TimedReportCallback {
(func: YCarbonDioxide, measure: YMeasure): void;
}
}