yoctolib-esm
Version:
Yoctopuce library for TypeScript/JavaScript, as an ECMAScript 2015 module
362 lines • 14.8 kB
JavaScript
/*********************************************************************
*
* $Id: svn_id $
*
* Implements the high-level API for Altitude functions
*
* - - - - - - - - - License information: - - - - - - - - -
*
* Copyright (C) 2011 and beyond by Yoctopuce Sarl, Switzerland.
*
* Yoctopuce Sarl (hereafter Licensor) grants to you a perpetual
* non-exclusive license to use, modify, copy and integrate this
* file into your software for the sole purpose of interfacing
* with Yoctopuce products.
*
* You may reproduce and distribute copies of this file in
* source or object form, as long as the sole purpose of this
* code is to interface with Yoctopuce products. You must retain
* this notice in the distributed source file.
*
* You should refer to Yoctopuce General Terms and Conditions
* for additional information regarding your rights and
* obligations.
*
* THE SOFTWARE AND DOCUMENTATION ARE PROVIDED 'AS IS' WITHOUT
* WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING
* WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY, FITNESS
* FOR A PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT. IN NO
* EVENT SHALL LICENSOR BE LIABLE FOR ANY INCIDENTAL, SPECIAL,
* INDIRECT OR CONSEQUENTIAL DAMAGES, LOST PROFITS OR LOST DATA,
* COST OF PROCUREMENT OF SUBSTITUTE GOODS, TECHNOLOGY OR
* SERVICES, ANY CLAIMS BY THIRD PARTIES (INCLUDING BUT NOT
* LIMITED TO ANY DEFENSE THEREOF), ANY CLAIMS FOR INDEMNITY OR
* CONTRIBUTION, OR OTHER SIMILAR COSTS, WHETHER ASSERTED ON THE
* BASIS OF CONTRACT, TORT (INCLUDING NEGLIGENCE), BREACH OF
* WARRANTY, OR OTHERWISE.
*
*********************************************************************/
import { YAPI, YFunction, YSensor } from './yocto_api.js';
//--- (YAltitude class start)
/**
* YAltitude Class: altimeter control interface, available for instance in the Yocto-Altimeter-V2 or
* the Yocto-GPS-V2
*
* The YAltitude class allows you to read and configure Yoctopuce altimeters.
* It inherits from YSensor class the core functions to read measurements,
* to register callback functions, and to access the autonomous datalogger.
* This class adds the ability to configure the barometric pressure adjusted to
* sea level (QNH) for barometric sensors.
*/
//--- (end of YAltitude class start)
export class YAltitude extends YSensor {
//--- (end of YAltitude attributes declaration)
constructor(yapi, func) {
//--- (YAltitude constructor)
super(yapi, func);
this._qnh = YAltitude.QNH_INVALID;
this._technology = YAltitude.TECHNOLOGY_INVALID;
this._valueCallbackAltitude = null;
this._timedReportCallbackAltitude = null;
// API symbols as object properties
this.QNH_INVALID = YAPI.INVALID_DOUBLE;
this.TECHNOLOGY_INVALID = YAPI.INVALID_STRING;
this._className = 'Altitude';
//--- (end of YAltitude constructor)
}
//--- (YAltitude implementation)
imm_parseAttr(name, val) {
switch (name) {
case 'qnh':
this._qnh = Math.round(val / 65.536) / 1000.0;
return 1;
case 'technology':
this._technology = val;
return 1;
}
return super.imm_parseAttr(name, val);
}
/**
* Changes the current estimated altitude. This allows one to compensate for
* ambient pressure variations and to work in relative mode.
* Remember to call the saveToFlash()
* method of the module if the modification must be kept.
*
* @param newval : a floating point number corresponding to the current estimated altitude
*
* @return YAPI.SUCCESS if the call succeeds.
*
* On failure, throws an exception or returns a negative error code.
*/
async set_currentValue(newval) {
let rest_val;
rest_val = String(Math.round(newval * 65536.0));
return await this._setAttr('currentValue', rest_val);
}
/**
* Changes the barometric pressure adjusted to sea level used to compute
* the altitude (QNH). This enables you to compensate for atmospheric pressure
* changes due to weather conditions. Applicable to barometric altimeters only.
* Remember to call the saveToFlash()
* method of the module if the modification must be kept.
*
* @param newval : a floating point number corresponding to the barometric pressure adjusted to sea
* level used to compute
* the altitude (QNH)
*
* @return YAPI.SUCCESS if the call succeeds.
*
* On failure, throws an exception or returns a negative error code.
*/
async set_qnh(newval) {
let rest_val;
rest_val = String(Math.round(newval * 65536.0));
return await this._setAttr('qnh', rest_val);
}
/**
* Returns the barometric pressure adjusted to sea level used to compute
* the altitude (QNH). Applicable to barometric altimeters only.
*
* @return a floating point number corresponding to the barometric pressure adjusted to sea level used to compute
* the altitude (QNH)
*
* On failure, throws an exception or returns YAltitude.QNH_INVALID.
*/
async get_qnh() {
let res;
if (this._cacheExpiration <= this._yapi.GetTickCount()) {
if (await this.load(this._yapi.defaultCacheValidity) != this._yapi.SUCCESS) {
return YAltitude.QNH_INVALID;
}
}
res = this._qnh;
return res;
}
/**
* Returns the technology used by the sesnor to compute
* altitude. Possibles values are "barometric" and "gps"
*
* @return a string corresponding to the technology used by the sesnor to compute
* altitude
*
* On failure, throws an exception or returns YAltitude.TECHNOLOGY_INVALID.
*/
async get_technology() {
let res;
if (this._cacheExpiration <= this._yapi.GetTickCount()) {
if (await this.load(this._yapi.defaultCacheValidity) != this._yapi.SUCCESS) {
return YAltitude.TECHNOLOGY_INVALID;
}
}
res = this._technology;
return res;
}
/**
* Retrieves an altimeter for a given identifier.
* The identifier can be specified using several formats:
*
* - FunctionLogicalName
* - ModuleSerialNumber.FunctionIdentifier
* - ModuleSerialNumber.FunctionLogicalName
* - ModuleLogicalName.FunctionIdentifier
* - ModuleLogicalName.FunctionLogicalName
*
*
* This function does not require that the altimeter is online at the time
* it is invoked. The returned object is nevertheless valid.
* Use the method YAltitude.isOnline() to test if the altimeter is
* indeed online at a given time. In case of ambiguity when looking for
* an altimeter by logical name, no error is notified: the first instance
* found is returned. The search is performed first by hardware name,
* then by logical name.
*
* If a call to this object's is_online() method returns FALSE although
* you are certain that the matching device is plugged, make sure that you did
* call registerHub() at application initialization time.
*
* @param func : a string that uniquely characterizes the altimeter, for instance
* YALTIMK2.altitude.
*
* @return a YAltitude object allowing you to drive the altimeter.
*/
static FindAltitude(func) {
let obj;
obj = YFunction._FindFromCache('Altitude', func);
if (obj == null) {
obj = new YAltitude(YAPI, func);
YFunction._AddToCache('Altitude', func, obj);
}
return obj;
}
/**
* Retrieves an altimeter for a given identifier in a YAPI context.
* The identifier can be specified using several formats:
*
* - FunctionLogicalName
* - ModuleSerialNumber.FunctionIdentifier
* - ModuleSerialNumber.FunctionLogicalName
* - ModuleLogicalName.FunctionIdentifier
* - ModuleLogicalName.FunctionLogicalName
*
*
* This function does not require that the altimeter is online at the time
* it is invoked. The returned object is nevertheless valid.
* Use the method YAltitude.isOnline() to test if the altimeter is
* indeed online at a given time. In case of ambiguity when looking for
* an altimeter by logical name, no error is notified: the first instance
* found is returned. The search is performed first by hardware name,
* then by logical name.
*
* @param yctx : a YAPI context
* @param func : a string that uniquely characterizes the altimeter, for instance
* YALTIMK2.altitude.
*
* @return a YAltitude object allowing you to drive the altimeter.
*/
static FindAltitudeInContext(yctx, func) {
let obj;
obj = YFunction._FindFromCacheInContext(yctx, 'Altitude', func);
if (obj == null) {
obj = new YAltitude(yctx, func);
YFunction._AddToCache('Altitude', func, obj);
}
return obj;
}
/**
* Registers the callback function that is invoked on every change of advertised value.
* The callback is then invoked only during the execution of ySleep or yHandleEvents.
* This provides control over the time when the callback is triggered. For good responsiveness,
* remember to call one of these two functions periodically. The callback is called once juste after beeing
* registered, passing the current advertised value of the function, provided that it is not an empty string.
* To unregister a callback, pass a null pointer as argument.
*
* @param callback : the callback function to call, or a null pointer. The callback function should take two
* arguments: the function object of which the value has changed, and the character string describing
* the new advertised value.
* @noreturn
*/
async registerValueCallback(callback) {
let val;
if (callback != null) {
await YFunction._UpdateValueCallbackList(this, true);
}
else {
await YFunction._UpdateValueCallbackList(this, false);
}
this._valueCallbackAltitude = callback;
// Immediately invoke value callback with current value
if (callback != null && await this.isOnline()) {
val = this._advertisedValue;
if (!(val == '')) {
await this._invokeValueCallback(val);
}
}
return 0;
}
async _invokeValueCallback(value) {
if (this._valueCallbackAltitude != null) {
try {
await this._valueCallbackAltitude(this, value);
}
catch (e) {
this._yapi.imm_log('Exception in valueCallback:', e);
}
}
else {
await super._invokeValueCallback(value);
}
return 0;
}
/**
* Registers the callback function that is invoked on every periodic timed notification.
* The callback is invoked only during the execution of ySleep or yHandleEvents.
* This provides control over the time when the callback is triggered. For good responsiveness, remember to call
* one of these two functions periodically. To unregister a callback, pass a null pointer as argument.
*
* @param callback : the callback function to call, or a null pointer. The callback function should take two
* arguments: the function object of which the value has changed, and an YMeasure object describing
* the new advertised value.
* @noreturn
*/
async registerTimedReportCallback(callback) {
let sensor;
sensor = this;
if (callback != null) {
await YFunction._UpdateTimedReportCallbackList(sensor, true);
}
else {
await YFunction._UpdateTimedReportCallbackList(sensor, false);
}
this._timedReportCallbackAltitude = callback;
return 0;
}
async _invokeTimedReportCallback(value) {
if (this._timedReportCallbackAltitude != null) {
try {
await this._timedReportCallbackAltitude(this, value);
}
catch (e) {
this._yapi.imm_log('Exception in timedReportCallback:', e);
}
}
else {
await super._invokeTimedReportCallback(value);
}
return 0;
}
/**
* Continues the enumeration of altimeters started using yFirstAltitude().
* Caution: You can't make any assumption about the returned altimeters order.
* If you want to find a specific an altimeter, use Altitude.findAltitude()
* and a hardwareID or a logical name.
*
* @return a pointer to a YAltitude object, corresponding to
* an altimeter currently online, or a null pointer
* if there are no more altimeters to enumerate.
*/
nextAltitude() {
let resolve = this._yapi.imm_resolveFunction(this._className, this._func);
if (resolve.errorType != YAPI.SUCCESS)
return null;
let next_hwid = this._yapi.imm_getNextHardwareId(this._className, resolve.result);
if (next_hwid == null)
return null;
return YAltitude.FindAltitudeInContext(this._yapi, next_hwid);
}
/**
* Starts the enumeration of altimeters currently accessible.
* Use the method YAltitude.nextAltitude() to iterate on
* next altimeters.
*
* @return a pointer to a YAltitude object, corresponding to
* the first altimeter currently online, or a null pointer
* if there are none.
*/
static FirstAltitude() {
let next_hwid = YAPI.imm_getFirstHardwareId('Altitude');
if (next_hwid == null)
return null;
return YAltitude.FindAltitude(next_hwid);
}
/**
* Starts the enumeration of altimeters currently accessible.
* Use the method YAltitude.nextAltitude() to iterate on
* next altimeters.
*
* @param yctx : a YAPI context.
*
* @return a pointer to a YAltitude object, corresponding to
* the first altimeter currently online, or a null pointer
* if there are none.
*/
static FirstAltitudeInContext(yctx) {
let next_hwid = yctx.imm_getFirstHardwareId('Altitude');
if (next_hwid == null)
return null;
return YAltitude.FindAltitudeInContext(yctx, next_hwid);
}
}
// API symbols as static members
YAltitude.QNH_INVALID = YAPI.INVALID_DOUBLE;
YAltitude.TECHNOLOGY_INVALID = YAPI.INVALID_STRING;
//# sourceMappingURL=yocto_altitude.js.map