UNPKG

scandit-sdk

Version:

Scandit Barcode Scanner SDK for the Web

485 lines 21.5 kB
"use strict"; Object.defineProperty(exports, "__esModule", { value: true }); var tslib_1 = require("tslib"); var eventemitter3_1 = require("eventemitter3"); var engineWorker_1 = require("./workers/engineWorker"); var index_1 = require("../index"); var barcode_1 = require("./barcode"); var browserHelper_1 = require("./browserHelper"); var customError_1 = require("./customError"); var imageSettings_1 = require("./imageSettings"); var parser_1 = require("./parser"); var scanResult_1 = require("./scanResult"); var scanSettings_1 = require("./scanSettings"); var unsupportedBrowserError_1 = require("./unsupportedBrowserError"); /** * @hidden */ var ScannerEventEmitter = /** @class */ (function (_super) { tslib_1.__extends(ScannerEventEmitter, _super); function ScannerEventEmitter() { return _super !== null && _super.apply(this, arguments) || this; } return ScannerEventEmitter; }(eventemitter3_1.EventEmitter)); /** * A low-level scanner interacting with the external Scandit Engine library. * Used to set up scan / image settings and to process single image frames. * * The loading of the external Scandit Engine library which takes place on creation can take some time, * the [[on]] method targeting the [[ready]] event can be used to set up a listener function to be called when the * library is loaded and the [[isReady]] method can return the current status. The scanner will be ready to start * scanning when the library is fully loaded. * * In the special case where a single [[Scanner]] instance is shared between multiple active [[BarcodePicker]] * instances, the fairness in resource allocation for processing images between the different pickers is not guaranteed. */ var Scanner = /** @class */ (function () { /** * Create a Scanner instance. * * It is required to having configured the library via [[configure]] before this object can be created. * * Before processing an image the relative settings must also have been set. * * If the library has not been correctly configured yet a `LibraryNotConfiguredError` error is thrown. * * If a browser is incompatible a `UnsupportedBrowserError` error is thrown. * * @param scanSettings <div class="tsd-signature-symbol">Default =&nbsp;new ScanSettings()</div> * The configuration object for scanning options. * @param imageSettings <div class="tsd-signature-symbol">Default =&nbsp;undefined</div> * The configuration object to define the properties of an image to be scanned. */ function Scanner(_a) { var _b = _a === void 0 ? {} : _a, _c = _b.scanSettings, scanSettings = _c === void 0 ? new scanSettings_1.ScanSettings() : _c, imageSettings = _b.imageSettings; var browserCompatibility = browserHelper_1.BrowserHelper.checkBrowserCompatibility(); if (!browserCompatibility.scannerSupport) { throw new unsupportedBrowserError_1.UnsupportedBrowserError(browserCompatibility); } if (index_1.userLicenseKey == null) { throw new customError_1.CustomError({ name: "LibraryNotConfiguredError", message: "The library has not correctly been configured yet, please call 'configure' with valid parameters" }); } this.isReadyToWork = false; this.workerScanQueueLength = 0; this.engineWorker = new Worker(URL.createObjectURL(engineWorker_1.engineWorkerBlob)); this.engineWorker.onmessage = this.engineWorkerOnMessage.bind(this); this.engineWorker.postMessage({ type: "load-library", deviceId: index_1.deviceId, libraryLocation: index_1.scanditEngineLocation, path: self.location.pathname, deviceModelName: browserHelper_1.BrowserHelper.userAgentInfo.getDevice().model, uaBrowserName: browserHelper_1.BrowserHelper.userAgentInfo.getBrowser().name }); this.eventEmitter = new eventemitter3_1.EventEmitter(); this.workerParseRequestId = 0; this.workerScanRequestId = 0; this.applyLicenseKey(index_1.userLicenseKey); this.applyScanSettings(scanSettings); if (imageSettings != null) { this.applyImageSettings(imageSettings); } } /** * Stop the internal `WebWorker` and destroy the scanner itself; ensuring complete cleanup. * * This method should be called after you don't plan to use the scanner anymore, * before the object is automatically cleaned up by JavaScript. * The barcode picker must not be used in any way after this call. */ Scanner.prototype.destroy = function () { if (this.engineWorker != null) { this.engineWorker.terminate(); } this.eventEmitter.removeAllListeners(); }; /** * Apply a new set of scan settings to the scanner (replacing old settings). * * @param scanSettings The scan configuration object to be applied to the scanner. * @returns The updated [[Scanner]] object. */ Scanner.prototype.applyScanSettings = function (scanSettings) { this.scanSettings = scanSettings; this.engineWorker.postMessage({ type: "settings", settings: this.scanSettings.toJSONString() }); this.eventEmitter.emit("newScanSettings", this.scanSettings); return this; }; /** * Apply a new set of image settings to the scanner (replacing old settings). * * @param imageSettings The image configuration object to be applied to the scanner. * @returns The updated [[Scanner]] object. */ Scanner.prototype.applyImageSettings = function (imageSettings) { this.imageSettings = imageSettings; this.engineWorker.postMessage({ type: "image-settings", imageSettings: imageSettings }); return this; }; /** * Clear the scanner session. * * This removes all recognized barcodes from the scanner session and allows them to be scanned again in case a custom * *codeDuplicateFilter* was set in the [[ScanSettings]]. * * @returns The updated [[Scanner]] object. */ Scanner.prototype.clearSession = function () { this.engineWorker.postMessage({ type: "clear-session" }); return this; }; /** * Process a given image using the previously set scanner and image settings, * recognizing codes and retrieving the result as a list of barcodes (if any). * * Multiple requests done without waiting for previous results will be queued and handled in order. * * If *highQualitySingleFrameMode* is enabled the image will be processed with really accurate internal settings, * resulting in much slower but more precise scanning results. This should be used only for single images not part * of a continuous video stream. * * Passing image data as a *Uint8ClampedArray* is the fastest option, passing a *HTMLImageElement* will incur * in additional operations. * * Depending on the current image settings, given *imageData* and scanning execution, any of the following errors * could be the rejected result of the returned promise: * - `NoImageSettings` * - `ImageSettingsDataMismatch` * - `ScanditEngineError` * * @param imageData The image data given as byte array or image element, complying with the previously set * image settings. * @param highQualitySingleFrameMode Whether to process the image as a high quality single frame. * @returns A promise resolving to the [[ScanResult]] object. */ Scanner.prototype.processImage = function (imageData, highQualitySingleFrameMode) { var _this = this; if (highQualitySingleFrameMode === void 0) { highQualitySingleFrameMode = false; } if (this.imageSettings == null) { return Promise.reject(new customError_1.CustomError({ name: "NoImageSettings", message: "No image settings set up in the scanner" })); } if (imageData instanceof HTMLImageElement) { if (this.imageDataConversionContext == null) { this.imageDataConversionContext = document.createElement("canvas").getContext("2d"); } this.imageDataConversionContext.canvas.width = imageData.naturalWidth; this.imageDataConversionContext.canvas.height = imageData.naturalHeight; this.imageDataConversionContext.drawImage(imageData, 0, 0, imageData.naturalWidth, imageData.naturalHeight); imageData = this.imageDataConversionContext.getImageData(0, 0, imageData.naturalWidth, imageData.naturalHeight) .data; } var channels; switch (this.imageSettings.format.valueOf()) { case imageSettings_1.ImageSettings.Format.GRAY_8U: channels = 1; break; case imageSettings_1.ImageSettings.Format.RGB_8U: channels = 3; break; case imageSettings_1.ImageSettings.Format.RGBA_8U: channels = 4; break; default: channels = 1; break; } if (this.imageSettings.width * this.imageSettings.height * channels !== imageData.length) { return Promise.reject(new customError_1.CustomError({ name: "ImageSettingsDataMismatch", message: "The provided image data doesn't match the previously set image settings" })); } this.workerScanRequestId++; this.workerScanQueueLength++; var originalImageData = imageData.slice(); return new Promise(function (resolve, reject) { var workResultEvent = "workResult-" + _this.workerScanRequestId; var workErrorEvent = "workError-" + _this.workerScanRequestId; _this.eventEmitter.once(workResultEvent, function (workResult) { _this.eventEmitter.removeAllListeners(workErrorEvent); resolve(new scanResult_1.ScanResult(workResult.scanResult.map(barcode_1.Barcode.createFromWASMResult), originalImageData, (_this.imageSettings))); }); _this.eventEmitter.once(workErrorEvent, function (error) { console.error("Scandit Engine error (" + error.errorCode + "):", error.errorMessage); _this.eventEmitter.removeAllListeners(workResultEvent); var errorObject = new customError_1.CustomError({ name: "ScanditEngineError", message: error.errorMessage + " (" + error.errorCode + ")" }); reject(errorObject); }); _this.engineWorker.postMessage({ type: "work", requestId: _this.workerScanRequestId, data: imageData, highQualitySingleFrameMode: highQualitySingleFrameMode }, [imageData.buffer]); }); }; /** * @returns Whether the scanner is currently busy processing an image. */ Scanner.prototype.isBusyProcessing = function () { return this.workerScanQueueLength !== 0; }; /** * @returns Whether the scanner has loaded the external Scandit Engine library and is ready to scan. */ Scanner.prototype.isReady = function () { return this.isReadyToWork; }; Scanner.prototype.on = function (eventName, listener) { if (eventName === "ready") { if (this.isReadyToWork) { listener(); } else { this.eventEmitter.once(eventName, listener, this); } } else if (eventName === "licenseFeaturesReady") { if (this.licenseFeatures != null) { listener(this.licenseFeatures); } else { this.eventEmitter.once(eventName, listener, this); } } else { this.eventEmitter.on(eventName, listener, this); } return this; }; /** * Add the listener function to the listeners array for the [[ready]] event, fired only once when the external * Scandit Engine library has been loaded and the scanner can thus start to scan barcodes. * If the external Scandit Engine library has already been loaded the listener is called immediately. * * No checks are made to see if the listener has already been added. * Multiple calls passing the same listener will result in the listener being added, and called, multiple times. * * @deprecated Use the [[on]] method instead. * * @param listener The listener function. * @returns The updated [[Scanner]] object. */ Scanner.prototype.onReady = function (listener) { console.warn("The onReady(<listener>) method is deprecated and will be removed in the next major library version." + 'Please use on("ready", <listener>) instead.'); return this.on("ready", listener); }; /** * *See the [[on]] method.* * * @param eventName The name of the event to listen to. * @param listener The listener function. * @returns The updated [[Scanner]] object. */ Scanner.prototype.addListener = function (eventName, listener) { return this.on(eventName, listener); }; /** * Create a new parser object. * * @param dataFormat The format of the input data for the parser. * @returns The newly created parser. */ Scanner.prototype.createParserForFormat = function (dataFormat) { return new parser_1.Parser(this, dataFormat); }; /** * Return the current image settings. * * Note that modifying this object won't directly apply these settings: the [[applyImageSettings]] method must be * called with the updated object. * * @returns The current image settings. */ Scanner.prototype.getImageSettings = function () { return this.imageSettings; }; /** * Return the current scan settings. * * Note that modifying this object won't directly apply these settings: the [[applyScanSettings]] method must be * called with the updated object. * * @returns The current scan settings. */ Scanner.prototype.getScanSettings = function () { return this.scanSettings; }; /** * @hidden * * Process a given string using the Scandit Parser library, * parsing the data in the given format and retrieving the result as a [[ParserResult]] object. * * Multiple requests done without waiting for previous results will be queued and handled in order. * * If parsing of the data fails the returned promise is rejected with a `ScanditEngineError` error. * * @param dataFormat The format of the given data. * @param dataString The string containing the data to be parsed. * @param options Options for the specific data format parser. * @returns A promise resolving to the [[ParserResult]] object. */ Scanner.prototype.parseString = function (dataFormat, dataString, options) { var _this = this; this.workerParseRequestId++; return new Promise(function (resolve, reject) { var parseStringResultEvent = "parseStringResult-" + _this.workerParseRequestId; var parseStringErrorEvent = "parseStringError-" + _this.workerParseRequestId; _this.eventEmitter.once(parseStringResultEvent, function (result) { _this.eventEmitter.removeAllListeners(parseStringErrorEvent); var parserResult = { jsonString: result, fields: [], fieldsByName: {} }; JSON.parse(result).forEach(function (parserField) { parserResult.fields.push(parserField); parserResult.fieldsByName[parserField.name] = parserField; }); resolve(parserResult); }); _this.eventEmitter.once(parseStringErrorEvent, function (error) { console.error("Scandit Engine error (" + error.errorCode + "):", error.errorMessage); _this.eventEmitter.removeAllListeners(parseStringResultEvent); var errorObject = new customError_1.CustomError({ name: "ScanditEngineError", message: error.errorMessage + " (" + error.errorCode + ")" }); reject(errorObject); }); _this.engineWorker.postMessage({ type: "parse-string", requestId: _this.workerParseRequestId, dataFormat: dataFormat, dataString: dataString, options: options == null ? "{}" : JSON.stringify(options) }); }); }; /** * @hidden * * Add the listener function to the listeners array for the "licenseFeaturesReady" event, fired only once * when the external Scandit Engine library has verified and loaded the license key and parsed its features. * If the license features are already available the listener is called immediately. * * No checks are made to see if the listener has already been added. * Multiple calls passing the same listener will result in the listener being added, and called, multiple times. * * @param listener The listener function, which will be invoked with a *licenseFeatures* object. * @returns The updated [[Scanner]] object. */ Scanner.prototype.onLicenseFeaturesReady = function (listener) { return this.on("licenseFeaturesReady", listener); }; /** * @hidden * * Add the listener function to the listeners array for the "newScanSettings" event, fired when new a new * [[ScanSettings]] object is applied via the [[applyScanSettings]] method. * * No checks are made to see if the listener has already been added. * Multiple calls passing the same listener will result in the listener being added, and called, multiple times. * * @param listener The listener function, which will be invoked with a [[ScanSettings]] object. * @returns The updated [[Scanner]] object. */ Scanner.prototype.onNewScanSettings = function (listener) { return this.on("newScanSettings", listener); }; /** * @hidden * * Remove the specified listener from the given event's listener array. * * @param eventName The name of the event from which to remove the listener. * @param listener The listener function to be removed. * @returns The updated [[Scanner]] object. */ Scanner.prototype.removeListener = function (eventName, listener) { this.eventEmitter.removeListener(eventName, listener); return this; }; Scanner.prototype.applyLicenseKey = function (licenseKey) { this.engineWorker.postMessage({ type: "license-key", licenseKey: licenseKey }); return this; }; Scanner.prototype.engineWorkerOnMessage = function (ev) { // tslint:disable:max-union-size var data = ev.data; // tslint:enable:max-union-size if (data[0] === "status" && data[1] === "ready") { this.isReadyToWork = true; this.eventEmitter.emit("ready"); } else if (data[1] != null) { if (data[0] === "license-features") { this.licenseFeatures = data[1]; this.eventEmitter.emit("licenseFeaturesReady", this.licenseFeatures); } else if (data[0] === "work-result") { this.eventEmitter.emit("workResult-" + data[1].requestId, data[1].result); this.workerScanQueueLength--; } else if (data[0] === "work-error") { this.eventEmitter.emit("workError-" + data[1].requestId, data[1].error); this.workerScanQueueLength--; } else if (data[0] === "parse-string-result") { this.eventEmitter.emit("parseStringResult-" + data[1].requestId, data[1].result); } else if (data[0] === "parse-string-error") { this.eventEmitter.emit("parseStringError-" + data[1].requestId, data[1].error); } } }; return Scanner; }()); exports.Scanner = Scanner; // istanbul ignore next (function (Scanner) { /** * @hidden * * Fired when the external Scandit Engine library has verified and loaded the license key and parsed its features. * * @asMemberOf Scanner * @event * @param licenseFeatures The features of the used license key. */ // @ts-ignore // declare function licenseFeaturesReady(licenseFeatures: any): void; /** * @hidden * * Fired when new a new [[ScanSettings]] object is applied via the [[applyScanSettings]] method. * * @asMemberOf Scanner * @event * @param newScanSettings The features of the used license key. */ // @ts-ignore // declare function newScanSettings(newScanSettings: any): void; })(Scanner = exports.Scanner || (exports.Scanner = {})); exports.Scanner = Scanner; //# sourceMappingURL=scanner.js.map