--- name: test-Valve symbols: - [ROV1101_OP, M30.0] - [ROV1101_CP, M30.1] - [ROV1101_RL, M30.2] - [ROV1101_ER, M30.3] - [ROV1101_HSO, M30.4] - [ROV1101_HSC, M30.5] - [ROV1101_HSS, M30.6] - [ROV1101_HSR, M30.7] - [ROV1101_ENOpen, M31.0, BOOL, 内部允许开] - [ROV1101_ENClose, M31.1, BOOL, 内部允许关] - [ROV1101_ENStop, M31.2, BOOL, 内部允许停止] - [ROV1101_ENVP, M31.3, BOOL, 内部允许阀位] - [ROV1101_open, M31.4, BOOL, 内部自保持开] - [ROV1101_close, M31.5, BOOL, 内部自保持关] - [ROV1101_mode, MW32, WORD, 模式] - [ROV1101_AI, MW34, WORD, 阀位采集值] - [ROV1101_position, MW36, INT, 阀位内部值] - [ROV1101_DR, MD38, DINT, 阀位执行时长] - [Valve_EMLT, FB100, Valve_EMLT, 阀模拟] - [ROV1101, DB701] - [ROV1101_EMLT, DB702, Valve_EMLT, 阀模拟] list : - comment: 阀测试 DB: ROV1101 AI: ROV1101_EMLT.AI OP: ROV1101_EMLT.OP CP: ROV1101_EMLT.CP remote: ROV1101_EMLT.RL error: ROV1101_EMLT.ER open_action: ROV1101_EMLT.HSO close_action: ROV1101_EMLT.HSC stop_action: ROV1101_EMLT.HSS control_action: ROV1101_EMLT.HSR $stop_delay: TIME#1S ...