prisme-flow
Version:
prisme platform flow engine
89 lines (78 loc) • 3.11 kB
HTML
<!--
Created by prisme.io on 09/06/2017.
@author <a href="mailto:hello@prisme.io">savane vamara</a> (prisme.io)
-->
<script type="text/javascript">
RED.nodes.registerType('modbus-flex-getter', {
category: 'plc',
color: '#E9967A',
defaults: {
name: {value: ""},
showStatusActivities: {value: false},
showErrors: {value: false},
server: {type: "modbus-client", required: true}
},
inputs: 1,
outputs: 2,
icon: "modbus.png",
paletteLabel: "Modbus-Flex-Getter",
label: function () {
return this.name || "modbus flex getter"
}
})
</script>
<script type="text/x-red" data-template-name="modbus-flex-getter">
<div class="form-row">
<label for="node-input-name"><i class="icon-tag"></i> <span>Name</span></label>
<input type="text" id="node-input-name" placeholder="Name">
</div>
<div class="form-row">
<label for="node-input-server"><i class="icon-globe"></i> <span>Server</span></label>
<input type="text" id="node-input-server">
</div>
<hr>
<div class="form-row">
<label style="min-width:160px" for="node-input-showStatusActivities"><i class="fa fa-th"></i> <span>show activities</span></label>
<input type="checkbox" id="node-input-showStatusActivities" style="max-width:30px">
</div>
<div class="form-row">
<label style="min-width:160px" for="node-input-showErrors"><i class="fa fa-th"></i> <span>show errors</span></label>
<input type="checkbox" id="node-input-showErrors" style="max-width:30px">
</div>
</script>
<script type="text/x-red" data-help-name="modbus-flex-getter">
<p>
Modbus TCP flexible input triggered read node with connection input parameters.
</p>
<p>Connects to a Modbus TCP or serial to read coils/inputs/registers at the rate of the incoming msg.</p>
<p>
<h4>Function codes (1:4) currently supported include:</h4>
<ul>
<li>FC 1: Read Coil Status</li>
<li>FC 2: Read Input Status</li>
<li>FC 3: Read Holding Registers</li>
<li>FC 4: Read Input Registers</li>
</ul>
</p>
<p>
<strong>Input parameter for connecting Modbus</strong>
<ul>
<li>unitid (0..255 tcp | 1..247 serial) - overrides default Unit-ID</li>
<li>fc (1..4)</li>
<li>start address (0:65535)</li>
<li>quantity (1:65535) of coils/inputs/registers to be read from the start address</li>
</ul>
</p>
<p>Output 1: data Array (PDU), modbus response Buffer, input message</p>
<p>Output 2: modbus response Buffer, data Array (PDU), input message</p>
<p>Function node code example for single input:</p>
<code>
msg.payload = { value: msg.payload, 'fc': 1, 'unitid': 1, 'address': 0 , 'quantity': 1 }
return msg
</code>
<p>Function node code example for multiple inputs:</p>
<code>
msg.payload = { value: msg.payload, 'fc': 3, 'unitid': 1, 'address': 0 , 'quantity': 10 }
return msg
</code>