UNPKG

perfetto-protos

Version:

Perfetto protos exposed via protobuf-es for browser and node

153 lines 5.97 kB
import type { GenEnum, GenFile, GenMessage } from "@bufbuild/protobuf/codegenv1"; import type { Message } from "@bufbuild/protobuf"; /** * Describes the file protos/perfetto/common/observable_events.proto. */ export declare const file_protos_perfetto_common_observable_events: GenFile; /** * @generated from message perfetto.protos.ObservableEvents */ export type ObservableEvents = Message<"perfetto.protos.ObservableEvents"> & { /** * @generated from field: repeated perfetto.protos.ObservableEvents.DataSourceInstanceStateChange instance_state_changes = 1; */ instanceStateChanges: ObservableEvents_DataSourceInstanceStateChange[]; /** * @generated from field: optional bool all_data_sources_started = 2; */ allDataSourcesStarted: boolean; /** * @generated from field: optional perfetto.protos.ObservableEvents.CloneTriggerHit clone_trigger_hit = 3; */ cloneTriggerHit?: ObservableEvents_CloneTriggerHit; }; /** * Describes the message perfetto.protos.ObservableEvents. * Use `create(ObservableEventsSchema)` to create a new message. */ export declare const ObservableEventsSchema: GenMessage<ObservableEvents>; /** * @generated from message perfetto.protos.ObservableEvents.DataSourceInstanceStateChange */ export type ObservableEvents_DataSourceInstanceStateChange = Message<"perfetto.protos.ObservableEvents.DataSourceInstanceStateChange"> & { /** * @generated from field: optional string producer_name = 1; */ producerName: string; /** * @generated from field: optional string data_source_name = 2; */ dataSourceName: string; /** * @generated from field: optional perfetto.protos.ObservableEvents.DataSourceInstanceState state = 3; */ state: ObservableEvents_DataSourceInstanceState; }; /** * Describes the message perfetto.protos.ObservableEvents.DataSourceInstanceStateChange. * Use `create(ObservableEvents_DataSourceInstanceStateChangeSchema)` to create a new message. */ export declare const ObservableEvents_DataSourceInstanceStateChangeSchema: GenMessage<ObservableEvents_DataSourceInstanceStateChange>; /** * @generated from message perfetto.protos.ObservableEvents.CloneTriggerHit */ export type ObservableEvents_CloneTriggerHit = Message<"perfetto.protos.ObservableEvents.CloneTriggerHit"> & { /** * The TracingSessionID of the original tracing session which had a * CLONE_SNAPSHOT trigger defined. This is necessary just because the * consumer has no idea of what is the TSID of its own tracing session and * there is no other good way to plumb it. * * @generated from field: optional int64 tracing_session_id = 1; */ tracingSessionId: bigint; /** * The name of the CLONE_SNAPSHOT trigger which was hit. * * @generated from field: optional string trigger_name = 2; */ triggerName: string; /** * The name of the producer that sent the CLONE_SNAPSHOT trigger. * * @generated from field: optional string producer_name = 3; */ producerName: string; /** * The uid of the producer that sent the CLONE_SNAPSHOT trigger. * * @generated from field: optional uint32 producer_uid = 4; */ producerUid: number; /** * The timestamp of the CLONE_SNAPSHOT trigger which was hit. * * @generated from field: optional uint64 boot_time_ns = 5; */ bootTimeNs: bigint; }; /** * Describes the message perfetto.protos.ObservableEvents.CloneTriggerHit. * Use `create(ObservableEvents_CloneTriggerHitSchema)` to create a new message. */ export declare const ObservableEvents_CloneTriggerHitSchema: GenMessage<ObservableEvents_CloneTriggerHit>; /** * @generated from enum perfetto.protos.ObservableEvents.Type */ export declare enum ObservableEvents_Type { /** * @generated from enum value: TYPE_UNSPECIFIED = 0; */ UNSPECIFIED = 0, /** * State changes of data source instances associated with the consumer's * session. Note that not all data sources may support these notifications. * See |will_notify_on_start/stop| in DataSourceDescriptor. * * @generated from enum value: TYPE_DATA_SOURCES_INSTANCES = 1; */ DATA_SOURCES_INSTANCES = 1, /** * State change triggered when all data sources are in the STARTED state. * For data sources that registered with |will_notify_on_start| this happens * only after the data source has acked the start. This allows the consumer * to synchronize with the data sources and to perform actions (e.g. start a * test binary) only after trace recording is actually started. * Introduced in Android 11 (R). * * @generated from enum value: TYPE_ALL_DATA_SOURCES_STARTED = 2; */ ALL_DATA_SOURCES_STARTED = 2, /** * When a tracing session has one or more triggers of type CLONE_SNAPSHOT * and a matching trigger is hit, the service will send this notification to * the consumer after |stop_delay_ms|. * * @generated from enum value: TYPE_CLONE_TRIGGER_HIT = 4; */ CLONE_TRIGGER_HIT = 4 } /** * Describes the enum perfetto.protos.ObservableEvents.Type. */ export declare const ObservableEvents_TypeSchema: GenEnum<ObservableEvents_Type>; /** * @generated from enum perfetto.protos.ObservableEvents.DataSourceInstanceState */ export declare enum ObservableEvents_DataSourceInstanceState { /** * A data source is created in stopped state. * * @generated from enum value: DATA_SOURCE_INSTANCE_STATE_STOPPED = 1; */ STOPPED = 1, /** * @generated from enum value: DATA_SOURCE_INSTANCE_STATE_STARTED = 2; */ STARTED = 2 } /** * Describes the enum perfetto.protos.ObservableEvents.DataSourceInstanceState. */ export declare const ObservableEvents_DataSourceInstanceStateSchema: GenEnum<ObservableEvents_DataSourceInstanceState>; //# sourceMappingURL=observable_events_pb.d.ts.map