UNPKG

node-red-contrib-vib-smart-boiler

Version:

Smart boiler node to control multiple thermostat

51 lines (41 loc) 2.91 kB
# Smart-Boiler this node belongs to a suite of nodes to control heating made by multiple intelligent Valve and a Central Boiler. The scheduling is done by Smart-Scheduler where multiple schedule and set-point can be defined, The valve management is done by Smart-Valve where multiple valve can be grouped in one room or group of room. And finally Smart-Boiler aims to control the boiler and to determine the right temperature and set point seeting according to the multiple valves. <b>Smart-Boiler</b> Received input from Smart-Valves and expect message as : msg.payload with: - sp for setpoint, int value - temp for current valve temperature, int value, - name for valve description, string value, - id for unique valve identification, int value ex input message: msg.payload={ sp:23,temp:20,name:"Valve kitchen", id:1} Each input received will either create a new entry in the valves stack or update the current entry in the stack. Smart-Boiler will determined the active valve to be sent to the Boiler, the active valve is determine by valve set point (target temperature) > valve current temperature and by the highest gap between set point and current temperature. Exemple : - Valve A : set point 19°C, current temperature 21 °C => inactive - Valve B : set point 23°C, current temperature 20 °C, gap is 3 °C => active but not sent to boiler, - Valve C : set point is 24°C and current temperature is 19°C, gap is 5°C => active and sent to the boiler. Additionnal functionnal rules: - If no active valve is found then highest sp of inactive valve is set as a reference to the boiler. - If no input after max duration (defined in setting), security message is sent to the boiler to avoid endless heating, Output: - Can be directly to MQTT (preferred); - regular output: msg.payload={ sp:23,temp:20,name:"Valve kitchen", id:1, lastTsUpdate: ISOTIME}; Configuration settings: MQTT: configuration node to define mqtt server connexion MQTT updates: when checked, update messages are directly sent to the defined topics Output updates: when checked, update messages are sent to the regular output, Set point topic: MQTT set Boiler set point topic Temperature topic: MQTT set Boiler current temperature topic Leading Device topic: MQTT Boiler text topic to indicate which valves is driving the heating Update cycle duration: valve stack evaluation duration cycle Max Duration since last input: maximum duration before sending security message to the boiler with default values Default temp: security message is sent with default temp Default set point: security message is sent with default set point ## Run locally <a href="https://www.buymeacoffee.com/vincentbe" target="_blank"><img src="https://cdn.buymeacoffee.com/buttons/v2/default-yellow.png" alt="Buy Me A Coffee" style="height: 60px !important;width: 217px !important;" ></a>