node-red-contrib-tinkerforge
Version:
Node-RED nodes to access Tinkerforge sensors
65 lines (55 loc) • 2.16 kB
JavaScript
/**
* Copyright 2017 IBM Corp.
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
**/
var Tinkerforge = require('tinkerforge');
var devices = require('../lib/devices');
module.exports = function(RED) {
"use strict";
function tinkerForgeAnalogOut(n) {
RED.nodes.createNode(this,n);
this.device = n.device;
this.sensor = n.sensor;
this.name = n.name;
var node = this;
node.ipcon = new Tinkerforge.IPConnection(); //devices[this.device].ipcon;
node.ipcon.setAutoReconnect(true);
var devs = devices.getDevices();
node.ipcon.connect(devs[node.device].host, devs[node.device].port,function(error){
if(error) {
node.warn("couldn't connect");
}
});
node.ipcon.on(Tinkerforge.IPConnection.CALLBACK_CONNECTED,
function(connectReason) {
node.ao = new Tinkerforge.BrickletAnalogOutV2(node.sensor, node.ipcon);
});
node.on('input', function(msg){
if(node.ao) {
if (typeof msg.payload === 'number') {
if (msg.payload >=0 && msg.payload <= 12) {
var v = Math.round(msg.payload * 1000);
node.ao.setOutputVoltage(v);
}
} else {
node.error("Payload not a number");
}
}
});
node.on('close',function() {
node.ipcon.disconnect();
});
}
RED.nodes.registerType('TinkerForge AnalogOut', tinkerForgeAnalogOut);
}