UNPKG

node-red-contrib-luxtronik2

Version:

Node, that reads and controls heat pumps based on the Luxtronik 2.0 contol unit. Supports for example AlphaInnotec and Siemens Novelan (WRP NET).

57 lines (50 loc) 1.89 kB
module.exports = function (RED) { "use strict"; var luxtronik = require('luxtronik2'); function Luxtronik2ReadNode(config) { RED.nodes.createNode(this, config); var node = this; var pump = luxtronik.createConnection(config.host, config.port); node.on('input', function (msg) { pump.read(function (err, data) { if (err) { msg.payload = err; return node.send(msg); } msg.payload = data; node.send(msg); }); }); } RED.nodes.registerType("luxtronik2 read", Luxtronik2ReadNode); function Luxtronik2WriteNode(config) { RED.nodes.createNode(this, config); var node = this; var pump = luxtronik.createConnection(config.host, config.port); node.on('input', function (msg) { var parameterName = config.parameter || msg.parameter; var parameterValue = msg.payload; var rawParameter = msg.raw_parameter; if(rawParameter !== undefined) { pump.writeRaw(rawParameter, parameterValue, function (err, data) { if (err) { node.error(err, msg); } else { msg.payload = data; node.send(msg); } }); } else { pump.write(parameterName, parameterValue, function (err, data) { if (err) { msg.payload = err; return node.send(msg); } msg.payload = data; node.send(msg); }); } }); } RED.nodes.registerType("luxtronik2 write", Luxtronik2WriteNode); }