Node, that reads and controls heat pumps based on the Luxtronik 2.0 contol unit. Supports for example AlphaInnotec and Siemens Novelan (WRP NET).

161 lines (155 loc) 7.88 kB
<script type="text/x-red" data-template-name="luxtronik2 read"> <div class="form-row"> <label for="node-input-host"><i class="fa fa-globe"></i> Host</label> <input type="text" id="node-input-host" placeholder="127.0.0.1"> </div> <div class="form-row"> <label for="node-input-port"><i class="fa fa-server"></i> Port</label> <input type="text" id="node-input-port" placeholder="8888"> </div> <div class="form-row"> <label for="node-input-name"><i class="fa fa-tag"></i> Name</label> <input type="text" id="node-input-name" placeholder="Name"> </div> </script> <script type="text/x-red" data-help-name="luxtronik2 read"> <p>Reads heat pumps based on the Luxtronik 2.0 contol unit.</p> <p>Connect your unit via LAN and configure the IP address parameters at your unit.</p> <p>Every incoming message to the Luxtronik2 node you get a message with all readable values from the heat pump.</p> </script> <script type="text/javascript"> RED.nodes.registerType("luxtronik2 read", { category: "input", defaults: { name: {name: ""}, host: {required: true}, port: {value: "8888"} }, color: "BurlyWood", inputs: 1, outputs: 1, icon: "db.png", paletteLabel: "luxtronik2", label: function() { return this.name || "luxtronik2"; }, labelStyle: function() { return this.name ? "node_label_italic" : ""; } }); </script> <script type="text/x-red" data-template-name="luxtronik2 write"> <div class="form-row"> <label for="node-input-host"><i class="fa fa-globe"></i> Host</label> <input type="text" id="node-input-host" placeholder="127.0.0.1"> </div> <div class="form-row"> <label for="node-input-port"><i class="fa fa-server"></i> Port</label> <input type="text" id="node-input-port" placeholder="8888"> </div> <div class="form-row"> <label for="node-input-parameter"><i class="fa fa-fish"></i> Parameter</label> <select type="text" id="node-input-parameter"> <option value=""></option> <option value="heating_target_temperature">Heating target temperature (1)</option> <option value="warmwater_target_temperature">Warmwater target temperature (2)</option> <option value="heating_operation_mode">Heating operation mode (3)</option> <option value="warmwater_operation_mode">Warmwater operation mode (4)</option> <option value="heating_curve_end_point">Heatingcurve endpoint (11)</option> <option value="heating_curve_parallel_offset">Heatingcurve parallel offset (12)</option> <option value="deltaHeatingReduction">Delta Heating reduction (13)</option> <option value="mk1_curve_end_point">MK1 curve endpoint (14)</option> <option value="mk1_curve_parallel_offset">MK1 curve parallel offset (15)</option> <option value="deltaMk1Reduction">MK1 curve Heating reduction (16)</option> <option value="hotwater_temperature_hysteresis">Hotwater temperature hysteresis (74)</option> <option value="return_temperature_hysteresis">Return temperature hysteresis (88)</option> <option value="heating_temperature_outside_2nd_compressor">Heating temperature outside 2nd compressor (95)</option> <option value="hotwater_temperature_forerun_2nd_compressor">Hot water temperature forerun 2nd compressor (96)</option> <option value="temperature_hot_water_target">Hot water target temperature (105)</option> <option value="cooling_operation_mode">Cooling operation mode (108)</option> <option value="cooling_release_temp">Cooling release temperature (110)</option> <option value="cooling_inlet_temp">Cooling inlet temperature (132)</option> <option value="runDeaerate">run Dearate (158)</option> <option value="hotWaterCircPumpDeaerate">Hot water circulation pump Dearate (684)</option> <option value="solarPumpDeaerate">Solar pump Dearate (688)</option> <option value="cooling_start">Cooling start (850)</option> <option value="cooling_stop">Cooling stop (851)</option> <option value="heating_system_circ_pump_voltage_nominal">Heating System circulation pump voltage nominal (867)</option> <option value="heating_system_circ_pump_voltage_minimal">Heating System circulation pump voltage minimal (868)</option> </select> </div> <div class="form-row"> <label for="node-input-name"><i class="fa fa-tag"></i> Name</label> <input type="text" id="node-input-name" placeholder="Name"> </div> <div class="form-tips">Tip: Leave parameter blank if you want to set them via msg.parameter.</div> </script> <script type="text/x-red" data-help-name="luxtronik2 write"> <p>Controls heat pumps based on the Luxtronik 2.0 contol unit.</p> <p>Connect your unit via LAN and configure the IP address parameters at your unit.</p> <h3>Inputs</h3> <dl class="message-properties"> <dt>payload <span class="property-type">string | number</span></dt> <dd> setvalue as number or string</dd> <dt class="optional">parameter <span class="property-type">string</span></dt> <dd> set parameter in config or leave it empty and set it via msg.parameter. <ul> <li>'heating_target_temperature'</li> <li>'warmwater_target_temperature'</li> <li>'heating_operation_mode'</li> <li>'warmwater_operation_mode'</li> <li>'heating_curve_end_point'</li> <li>'heating_curve_parallel_offset'</li> <li>'deltaHeatingReduction'</li> <li>'mk1_curve_end_point'</li> <li>'mk1_curve_parallel_offset'</li> <li>'deltaMk1Reduction'</li> <li>'hotwater_temperature_hysteresis'</li> <li>'return_temperature_hysteresis'</li> <li>'heating_temperature_outside_2nd_compressor'</li> <li>'hotwater_temperature_forerun_2nd_compressor'</li> <li>'temperature_hot_water_target'</li> <li>'cooling_operation_mode'</li> <li>'cooling_release_temp'</li> <li>'cooling_inlet_temp'</li> <li>'runDeaerate'</li> <li>'hotWaterCircPumpDeaerate'</li> <li>'solarPumpDeaerate'</li> <li>'cooling_start'</li> <li>'cooling_stop'</li> <li>'heating_system_circ_pump_voltage_nominal'</li> <li>'heating_system_circ_pump_voltage_minimal'</li> </ul> </dd> <dt class="optional">raw_parameter <span class="property-type">number</span></dt> <dd> Use RAW write operation to heat pump by passing the heat pump parameter directly as number via <code>msg.raw_parameter</code>. The config option 'parameter' or <code>msg.parameter</code> is ignored in this case. The RAW parameter value must be provided via <code>msg.payload</code>. Attention: No automatic parameter format conversions are done in this mode. </dd> </dl> </script> <script type="text/javascript"> RED.nodes.registerType("luxtronik2 write", { category: "output", defaults: { name: {name: ""}, host: {required: true}, port: {value: "8888"}, parameter: {value: ""} }, color:"BurlyWood", inputs: 1, outputs: 1, icon: "db.png", align: "right", paletteLabel: "luxtronik2", label: function() { return this.name || "luxtronik2"; }, labelStyle: function() { return this.name ? "node_label_italic" : ""; } }); </script>