UNPKG

node-red-contrib-knx-ultimate

Version:

Control your KNX and KNX Secure intallation via Node-Red! A bunch of KNX nodes, with integrated Philips HUE control, ETS group address importer, KNX AI for diagnosticsand KNX routing between interfaces. Easy to use and highly configurable.

60 lines (59 loc) 3.08 kB
{ "knxUltimateStaircase": { "title": "Staircase light", "paletteLabel": "Staircase", "node-input-server": "KNX Gateway", "node-input-name": "Name", "node-input-outputtopic": "Topic for emitted events", "trigger": "Trigger GA", "output": "Output GA", "status": "Status GA", "override": "Override GA", "block": "Block GA", "node-input-timerSeconds": "Timer duration (seconds)", "node-input-extendMode": "On new trigger", "extend_restart": "Restart timer", "extend_extend": "Extend remaining time", "extend_ignore": "Ignore the trigger", "node-input-triggerOffCancels": "0 command cancels the cycle", "opt_yes": "Yes", "opt_no": "No", "node-input-blockAction": "When blocked", "block_off": "Force light OFF", "block_keep": "Leave current state", "node-input-preWarnEnable": "Send pre-warning before timeout", "node-input-preWarnSeconds": "Pre-warning offset (seconds)", "node-input-preWarnMode": "Pre-warning mode", "prewarn_status": "Toggle status GA", "prewarn_flash": "Flash output", "node-input-preWarnFlashMs": "Flash duration (ms)", "node-input-emitEvents": "Emit events on node output", "help": { "intro": "Implements a staircase light logic with KNX integration, handling timer, pre-warning, manual override and blocking.", "trigger": "Triggers", "trigger_ga": "A rising edge (value = 1) on the trigger GA starts the timer. If enabled, a value of 0 will immediately cancel the cycle.", "extend": "The \"On new trigger\" option controls how subsequent pulses behave: restart the timer, extend the remaining time or ignore the pulse.", "off": "When override is active the timer is paused and the light stays on. Blocking disables new pulses and optionally forces the output off.", "outputs": "Group addresses", "output_ga": "Output GA is driven with DPT 1.001 by default. Configure other DPTs if required.", "status_ga": "Status GA mirrors the stair light state (and the pre-warning flag when enabled).", "override_ga": "Override GA keeps the light on while true and suspends the timer.", "block_ga": "Block GA prevents new activations. When false, normal behaviour resumes.", "prewarn": "Pre-warning", "prewarn_desc": "Enable a pre-warning to alert occupants before the light turns off. You can either flash the output or toggle the status GA.", "events": "Node output", "events_desc": "When enabled the node emits structured events (trigger, extend, prewarn, timeout, override, block) with the remaining time and state information." }, "placeholders": { "outputtopic": "Optional topic for node events", "ga": "e.g. 1/1/5", "triggerName": "Trigger device name", "outputName": "Output actuator name", "statusName": "Status feedback name", "overrideName": "Override channel name", "blockName": "Block command name" }, "section_commands": "Command group addresses", "section_inputs": "Input group addresses" } }