"knxUltimateGarage": {
"title": "Garage door",
"paletteLabel": "Garage",
"node-input-server": "KNX Gateway",
"node-input-name": "Name",
"node-input-outputtopic": "Topic for emitted events",
"command": "Command GA (true=open, false=close)",
"impulse": "Impulse GA",
"holdOpen": "Hold-open GA",
"disable": "Disable GA",
"photocell": "Photocell GA",
"moving": "Moving GA",
"obstruction": "Obstruction GA",
"autoCloseEnable": "Enable auto re-close",
"autoCloseSeconds": "Auto re-close delay (seconds)",
"node-input-emitEvents": "Emit events on node output",
"placeholders": {
"outputtopic": "Optional topic for node events",
"ga": "e.g. 1/2/3",
"commandName": "Door actuator",
"impulseName": "Impulse input",
"holdOpenName": "Hold-open switch",
"disableName": "Disable command",
"photocellName": "Photocell sensor",
"movingName": "Movement indicator",
"obstructionName": "Obstruction indicator"
},
"help": {
"intro": "Controls a KNX garage door with direct open/close commands, impulse inputs, safety sensors and automatic re-close.",
"commands": "Commands",
"command_ga": "Use the command GA for boolean control: true opens, false closes. The node also emits this when the auto close triggers.",
"impulse_ga": "An impulse GA toggles the door. Rising edges toggle the internal state; it is also used if no direct command GA is configured.",
"holdopen_ga": "Hold-open GA keeps the door open and cancels the auto re-close until it returns to false.",
"disable_ga": "Disable GA stops the node from issuing new commands. Useful for maintenance or manual mode.",
"safety": "Safety and status",
"photocell_ga": "The photocell GA should go true when the beam is interrupted. The node re-opens the door and flags obstruction.",
"moving_ga": "Movement GA (optional) is pulsed whenever the node commands the door to move, allowing other devices to follow the motion.",
"obstruction_ga": "Obstruction GA mirrors the obstruction state so other KNX components can react.",
"auto": "Automatic re-close",
"auto_close": "Enable the auto re-close timer to close the door automatically after the configured delay once it is open, unless hold-open or disable are active.",
"events": "Node output",
"events_desc": "With event emission enabled the node outputs structured messages (open, close, toggle, obstruction, disabled, hold-open, auto-close) for flow logic."
},
"section_commands": "Command group addresses",
"section_inputs": "Input / sensor group addresses"
}
}