node-red-contrib-knx-ultimate
Version:
Control your KNX and KNX Secure intallation via Node-Red! A bunch of KNX nodes, with integrated Philips HUE control and ETS group address importer. Easy to use and highly configurable.
142 lines (129 loc) • 5.78 kB
JavaScript
module.exports = function (RED) {
function knxUltimateHuedevice_software_update(config) {
RED.nodes.createNode(this, config);
const node = this;
node.serverKNX = RED.nodes.getNode(config.server) || undefined;
node.serverHue = RED.nodes.getNode(config.serverHue) || undefined;
node.topic = node.name;
node.name = config.name === undefined ? 'Hue' : config.name;
node.dpt = '';
node.notifyreadrequest = true;
node.notifyreadrequestalsorespondtobus = 'false';
node.notifyreadrequestalsorespondtobusdefaultvalueifnotinitialized = '';
node.notifyresponse = false;
node.notifywrite = true;
node.initialread = true;
node.listenallga = true; // Don't remove
node.outputtype = 'write';
node.outputRBE = 'false'; // Apply or not RBE to the output (Messages coming from flow)
node.inputRBE = 'false'; // Apply or not RBE to the input (Messages coming from BUS)
node.currentPayload = ''; // Current value for the RBE input and for the .previouspayload msg
node.passthrough = 'no';
node.formatmultiplyvalue = 1;
node.formatnegativevalue = 'leave';
node.formatdecimalsvalue = 2;
node.hueDevice = config.hueDevice;
node.initializingAtStart = (config.readStatusAtStartup === undefined || config.readStatusAtStartup === "yes");
node.currentDeviceValue = false;
// Used to call the status update from the config node.
node.setNodeStatus = ({
fill, shape, text, payload,
}) => {
try {
if (payload === undefined) payload = '';
const dDate = new Date();
payload = typeof payload === "object" ? JSON.stringify(payload) : payload.toString();
node.sKNXNodeStatusText = `|KNX: ${text} ${payload} (${dDate.getDate()}, ${dDate.toLocaleTimeString()})`;
node.status({ fill, shape, text: (node.sHUENodeStatusText || '') + ' ' + (node.sKNXNodeStatusText || '') });
} catch (error) { }
};
// Used to call the status update from the HUE config node.
node.setNodeStatusHue = ({ fill, shape, text, payload }) => {
try {
if (payload === undefined) payload = '';
const dDate = new Date();
payload = typeof payload === "object" ? JSON.stringify(payload) : payload.toString();
node.sHUENodeStatusText = `|HUE: ${text} ${payload} (${dDate.getDate()}, ${dDate.toLocaleTimeString()})`;
node.status({ fill, shape, text: node.sHUENodeStatusText + ' ' + (node.sKNXNodeStatusText || '') });
} catch (error) { }
};
// This function is called by the knx-ultimate config node, to output a msg.payload.
node.handleSend = (msg) => {
// Respond to KNX read telegram, by sending the current value as response telegram.
if (msg.knx.event === "GroupValue_Read") {
switch (msg.knx.destination) {
case config.GAdevice_software_update:
// To the KNX bus wires
node.sendResponseToKNX(node.currentDeviceValue);
break;
default:
break;
}
}
};
node.handleSendHUE = (_event) => {
try {
// Event status: one of connected, disconnected, connectivity_issue, unidirectional_incoming
if (_event.id === config.hueDevice) {
if (!_event.hasOwnProperty("state") || _event.state === undefined) return;
const knxMsgPayload = {};
knxMsgPayload.topic = config.GAdevice_software_update;
knxMsgPayload.dpt = config.dptdevice_software_update;
knxMsgPayload.payload = (_event.state !== "no_update");
// Send to KNX bus
if (knxMsgPayload.topic !== '' && knxMsgPayload.topic !== undefined) {
node.serverKNX.sendKNXTelegramToKNXEngine({
grpaddr: knxMsgPayload.topic, payload: knxMsgPayload.payload, dpt: knxMsgPayload.dpt, outputtype: 'write', nodecallerid: node.id,
});
}
node.currentDeviceValue = knxMsgPayload.payload;
// Setup the output msg
knxMsgPayload.name = node.name;
knxMsgPayload.status = _event.state;
knxMsgPayload.event = 'device_software_update';
// Send payload
knxMsgPayload.rawEvent = _event;
node.send(knxMsgPayload);
node.setNodeStatusHue({
fill: 'blue', shape: 'ring', text: 'HUE->KNX', payload: knxMsgPayload.payload,
});
}
} catch (error) {
node.status({ fill: 'red', shape: 'dot', text: `HUE->KNX error ${error.message} (${new Date().getDate()}, ${new Date().toLocaleTimeString()})` });
}
};
node.sendResponseToKNX = (_level) => {
const knxMsgPayload = {};
knxMsgPayload.topic = config.GAdevice_software_update;
knxMsgPayload.dpt = config.dptdevice_software_update;
knxMsgPayload.payload = _level;
// Send to KNX bus
if (knxMsgPayload.topic !== '' && knxMsgPayload.topic !== undefined) {
node.serverKNX.sendKNXTelegramToKNXEngine({
grpaddr: knxMsgPayload.topic, payload: knxMsgPayload.payload, dpt: knxMsgPayload.dpt, outputtype: 'response', nodecallerid: node.id,
});
}
};
// On each deploy, unsubscribe+resubscribe
if (node.serverKNX) {
node.serverKNX.removeClient(node);
node.serverKNX.addClient(node);
}
if (node.serverHue) {
node.serverHue.removeClient(node);
node.serverHue.addClient(node);
}
node.on('input', (msg) => {
});
node.on('close', (done) => {
if (node.serverKNX) {
node.serverKNX.removeClient(node);
}
if (node.serverHue) {
node.serverHue.removeClient(node);
}
done();
});
}
RED.nodes.registerType('knxUltimateHuedevice_software_update', knxUltimateHuedevice_software_update);
};