module.exports = function (RED) {
// msg is:
// // Build final input message object
// return {
// topic: _outputtopic
// , payload: jsValue
// , devicename: (typeof _devicename !== 'undefined') ? _devicename : ""
// , payloadmeasureunit: sPayloadmeasureunit
// , payloadsubtypevalue: sPayloadsubtypevalue
// , knx:
// {
// event: _event
// , dpt: sInputDpt
// //, details: dpt
// , dptdesc: sDptdesc
// , source: _srcGA
// , destination: _destGA
// , rawValue: _Rawvalue
// }
// };
// The node.exposedGAs is and array of:
// {
// address,
// dpt,
// payload
// lastupdate
// lastupdateLocale
// }
function knxUltimateGlobalContext (config) {
RED.nodes.createNode(this, config)
const node = this
node.serverKNX = RED.nodes.getNode(config.server) || undefined
node.topic = node.name
node.name = config.name === undefined ? 'KNXGlobalContext' : config.name
node.outputtopic = node.name
node.dpt = ''
node.notifyreadrequest = false
node.notifyreadrequestalsorespondtobus = 'false'
node.notifyreadrequestalsorespondtobusdefaultvalueifnotinitialized = ''
node.notifyresponse = true
node.notifywrite = true
node.initialread = false
node.listenallga = true
node.outputtype = 'write'
node.outputRBE = 'false' // Apply or not RBE to the output (Messages coming from flow)
node.inputRBE = 'false' // Apply or not RBE to the input (Messages coming from BUS)
node.currentPayload = '' // Current value for the RBE input and for the .previouspayload msg
node.passthrough = 'no'
node.formatmultiplyvalue = 1
node.formatnegativevalue = 'leave'
node.formatdecimalsvalue = 999
node.writeExecutionInterval = config.writeExecutionInterval === undefined ? 1000 : config.writeExecutionInterval
node.contextStorage = config.contextStorage !== undefined ? config.contextStorage : ''
node.exposeAsVariable = config.exposeAsVariable !== undefined ? config.exposeAsVariable : 'exposeAsVariableREADONLY' // Should expose the Group Addresses to the Global Context?
node.exposedGAs = []
node.timerExposedGAs = null
const pushStatus = (status) => {
if (!status) return
const provider = node.serverKNX
if (provider && typeof provider.applyStatusUpdate === 'function') {
provider.applyStatusUpdate(node, status)
} else {
node.status(status)
}
}
const updateStatus = (status) => {
if (!status) return
pushStatus(status)
}
// Used to call the status update from the config node.
node.setNodeStatus = ({ fill, shape, text, payload, GA, dpt, devicename }) => {
try {
if (node.serverKNX === null) { updateStatus({ fill: 'red', shape: 'dot', text: '[NO GATEWAY SELECTED]' }); return }
GA = GA === undefined ? '' : GA
payload = payload === undefined ? '' : payload
payload = typeof payload === 'object' ? JSON.stringify(payload) : payload
const dDate = new Date()
updateStatus({ fill, shape, text: GA + ' ' + payload + ' ' + text + ' (' + dDate.getDate() + ', ' + dDate.toLocaleTimeString() + ')' })
} catch (error) {
}
}
// 02/12/2022 Expose the complete ETS CSV as well
if (node.exposeAsVariable !== 'exposeAsVariableNO') {
try {
node.serverKNX.csv.forEach(element => {
node.exposedGAs.push({ address: element.ga, dpt: element.dpt, devicename: element.devicename, payload: undefined, lastupdate: undefined, lastupdateLocale: undefined })
})
} catch (error) {
}
}
// exposeAsVariableREADWRITE
// #region "WRITE TO BUS"
node.goTimerGo = function () {
if (node.timerExposedGAs !== null) clearTimeout(node.timerExposedGAs) // 21/03/2021
node.timerExposedGAs = setTimeout(() => {
let oContext = node.context().global.get(node.name + '_WRITE', node.contextStorage) || []
node.context().global.set(node.name + '_WRITE', [], node.contextStorage) // Delete the var
for (let index = 0; index < oContext.length; index++) {
const element = oContext[index]
if (element.hasOwnProperty('address') === false) {
node.setNodeStatus({ fill: 'RED', shape: 'dot', text: 'NO Group Address set', payload: '', GA: '', dpt: '', devicename: '' })
RED.log.error('knxUltimateGlobalContext: No group address set in node ' + node.id)
oContext = null // 21/03/2022
node.goTimerGo()
return
}
if (element.hasOwnProperty('payload') === false) {
node.setNodeStatus({ fill: 'RED', shape: 'dot', text: 'NO payload set', payload: '', GA: '', dpt: '', devicename: '' })
RED.log.error('knxUltimateGlobalContext: No payload set for address ' + element.address + ' in node ' + node.id)
oContext = null // 21/03/2022
node.goTimerGo()
return
}
// 13/09/2021 retrieve the datapoint if not specified
if (element.hasOwnProperty('dpt') === false || element.dpt === undefined || element.dpt === '') {
try {
const sDPT = node.serverKNX.csv.find(item => item.ga === element.address).dpt
element.dpt = sDPT
} catch (error) {
node.setNodeStatus({ fill: 'RED', shape: 'dot', text: 'Datapoint not found in CSV for ' + element.address, payload: '', GA: '', dpt: '', devicename: '' })
RED.log.error('knxUltimateGlobalContext: Datapoint not found in CSV for address ' + element.address + ' in node ' + node.id)
oContext = null // 21/03/2022
node.goTimerGo()
return
}
}
node.setNodeStatus({ fill: 'green', shape: 'dot', text: 'Write', payload: element.payload, GA: element.address, dpt: element.dpt || '', devicename: '' })
node.serverKNX.sendKNXTelegramToKNXEngine({ grpaddr: element.address, payload: element.payload, dpt: element.dpt || '', outputtype: 'write', nodecallerid: node.id })
}
oContext = null // 21/03/2022
node.goTimerGo()
}, node.writeExecutionInterval)
}
// 21/02/2021 timer for write to BUS
if (node.exposeAsVariable === 'exposeAsVariableREADWRITE') {
node.goTimerGo()
node.setNodeStatus({ fill: 'green', shape: 'dot', text: 'Start Writing', payload: '', GA: '', dpt: '', devicename: '' })
} else {
if (node.timerExposedGAs !== null) clearTimeout(node.timerExposedGAs)
node.context().global.set(node.name + '_WRITE', [], node.contextStorage) // Delete the var
}
// #endregion
// This function is called by the knx-ultimate config node, to output a msg.payload.
node.handleSend = msg => {
if (node.exposeAsVariable !== 'exposeAsVariableNO') {
try {
var oGa = node.exposedGAs.find(ga => ga.address === msg.knx.destination)
} catch (error) {
console.log(error)
}
const dNow = new Date()
const lastupdate = dNow.toISOString()
const lastupdateLocale = dNow.toLocaleString()
if (oGa === undefined) {
node.exposedGAs.push({ address: msg.knx.destination, devicename: undefined, dpt: msg.knx.dpt, payload: msg.payload, lastupdate, lastupdateLocale })
} else {
oGa.dpt = msg.knx.dpt
oGa.payload = msg.payload
oGa.lastupdate = lastupdate
oGa.lastupdateLocale = lastupdateLocale
}
// Save into the global Context
try {
node.context().global.set(node.name + '_READ', node.exposedGAs, node.contextStorage)
} catch (error) {
console.log(error)
}
oGa = null // 21/03/2022
} else {
node.exposedGAs = []
node.context().global.set(node.name + '_READ', node.exposedGAs, node.contextStorage)
}
}
node.on('input', function (msg) {
})
node.on('close', function (done) {
if (node.timerExposedGAs !== null) clearTimeout(node.timerExposedGAs)
node.exposedGAs = []
if (node.serverKNX) {
node.serverKNX.removeClient(node)
}
done()
})
// On each deploy, unsubscribe+resubscribe
if (node.serverKNX) {
node.serverKNX.removeClient(node)
node.serverKNX.addClient(node)
}
}