UNPKG

node-red-contrib-kitra

Version:

kitra-com node-red module

68 lines (65 loc) 2.82 kB
<script type="text/javascript"> RED.nodes.registerType('lra_configure',{ category: 'kitra output', color: '#a6bbcf', defaults: { name: {value:""}, pin: {value:1, required:true}, managed: {value:"true", required:true}, percentage: {value:50, required:false}, effect_number: {value:70, required:false}, autostart: {value:"true", required:true}, }, inputs:1, outputs:1, icon:"kitra.png", label: function() { return this.name||"lra_configure"; } }); </script> <script type="text/x-red" data-template-name="lra_configure"> <div class="form-row"> <label for="node-input-name"><i class="icon-tag"></i> Name</label> <input type="text" id="node-input-name" placeholder="Name"> </div> <div class="form-row"> <label for="node-input-pin"><i class="fa"></i> Pin </label> <input type="text" id="node-input-pin"> </div> <div class="form-row"> <label for="node-input-managed"><i class="fa fa-rocket"></i> Managed </label> <select type="text" id="node-input-managed" > <option value="true">Enabled</option> <option value="false">Disabled</option> </select> </div> <div class="form-row"> <label for="node-input-percentage"><i class="fa fa-percent"></i> Percentage </label> <input type="text" id="node-input-percentage"> </div> <div class="form-row"> <label for="node-input-effect_number"><i class="fa fa-list"></i> Effect Number </label> <input type="text" id="node-input-effect_number"> </div> <div class="form-row"> <label for="node-input-autostart"><i class="fa fa-road"></i> Autostart </label> <select type="text" id="node-input-autostart" > <option value="true">Yes</option> <option value="false">No</option> </select> </div> </div> </script> <script type="text/x-red" data-help-name="lra_configure"> <p>Lra configuration</p> <ul> <li>Pin: which motor drive, for now only pin 1 is avaiable If no value is provided <code>msg.lra_pin</code>will be used..</li> <li>Managed: If enabled use embedded effects (check drv2605l datasheet 'Waveform Library Effects List'), if disabled use percentage value.</li> <li>Percentage: Used only if managed is disabled. If no value is provided <code>msg.lra_percentage[pin-1]</code>will be used.</li> <li>Effect: Wich effect use in managed mode, values range from 1 to 123. If no value is provided <code>msg.lra_effect_number[pin-1]</code>will be used.</li> <li>Autostart: For future use. leave that to true. </li> </ul> <p><b>Known issue:</b> For now PWM can be felt only with values > 51 with the motor we provide.</p> </script>