# node-red-contrib-atipsae
Node-RED node for ADVANTECH IIoT [UNO-IPS2730-AE](http://www.advantech.com/products/1-2mlj2z/uno-ips2730-ae/mod_2ca60cb5-a216-4f76-accb-4c3108e8621e).
Notice that an Advantech IIoT Platform SDK have to be installed to make this node works correctly.
Advantech IIoT Platform SDK download link is shown below:
Windows:
https://github.com/Advantech-IIoT/Platform-SDK/tree/master/windows/bin
Linux:
https://github.com/Advantech-IIoT/Platform-SDK/tree/master/linux/bin
## Installation
Use npm command to install this package locally in the Node-RED modules directory
```bash
npm install node-red-contrib-atipsae
```
or install it globally with the command
```bash
npm install node-red-contrib-atipsae -g
```
## Description
You must use the Node-RED with [UNO-IPS2730-AE](http://www.advantech.com/products/1-2mlj2z/uno-ips2730-ae/mod_2ca60cb5-a216-4f76-accb-4c3108e8621e).
## Example
You can try demo flow [demo.json](./demo.json) via import function from Node-RED editor.

The inputs must be [**msg.payload.UPSInputLostDelay**](./#) and [**msg.payload.UPSCutOffDelay**](./#) which are numeric.
[**msg.payload.UPSInputLostDelay**](./#) is a number which is the DC Input Lost detection duration(sec).
[**msg.payload.UPSCutOffDelay**](./#) is a number which is the DC-OUT cut-off delay time(minutes).
Another input [**msg.payload.port**](./#) is COM port name which is used to connect with UPS.
- - -
There are 3 outputs, [**Emergency**](./#), [**Status**](./#) and [**Response**](./#).
The [**Emergency**](./#) output is a string and consists of the following.
"**DC-IN is Losted**"
"**Battery Over Temperature**"
"**Battery Gauge is Lost Connection**"
"**EEPROM Access Fail**"
"**DC-IN is Over Voltage**"
"**The DC-Out Cut-Off trigger**"
"**Restores power to IPS-AE DC-IN**"
The [**Status**](./#) output is a javascript object format in msg.payload and the object contents are as follows
**fwversion** : DEVICE firmware version
**ips** : the status of DEVICE. 1 is ready and 0 is not ready
**dcin** : the status of DC-IN. 1 is ready and 0 is not ready
**battery** : the status of BATTERY. 1 is ready and 0 is not ready
**inputlostdelay** : the DC Input Lost detection duration(sec)
**utoffdelay** : the DC-OUT cut-off delay time(minutes)
**atterylife** : BATTERY life(minutes) at the present rate of discharge. "65535" is BATTERY charged.
**emperature** : BATTERY temperature(celsius)
**maxtemperature** : It's the max temperature(celsius) of BATTERY from the system started.
**batteryvoltage** : It's the the BATTERY voltage(mV).
**capacity** : BATTERY capacity(%)
The [**Response**](./#). output is a string to describe the input result.
---
## Tested Platform
- Windows 10 Enterprise LTSC with node.js 18.14.1
## History
- 3.0.1 - June 2023 : update for NODE_MODULE_VERSION=108 (C++ addons use Node-API)
- 2.0.1 - November 2019 : update for NODE_MODULE_VERSION=64 (C++ addons use Native Abstractions for Node.js)
- 1.1.7 - October 2017 : Initial Release
## License
Copyright 2019 ADVANTECH Corp. under [the Apache 2.0 license](LICENSE).