UNPKG

node-enocean

Version:

full implementation of the enocean protocol (ESP3 + EEP2.6)

150 lines 8.36 kB
module.exports = { "f6-02" : "Rocker Switch, 2 Rocker", "f6-02-01" : "Light and Blind Control - Application Style 1", "f6-02-02" : "Light and Blind Control - Application Style 1", "f6-02-03" : "Light Control - Application Style 1", "f6-02-04" : "Light and Blind Control ERP2", "f6-03" : "Rocker Switch 4 Rocker", "f6-03-01" : "Light and Blind Control - Application Style 1", "f6-03-02" : "Light and Blind Control - Application Style 2", "f6-04" : "Position Switch, Home and Office Application", "f6-04-01" : "Key Card Activation Switch", "f6-04-02" : "Key Card Activation Switch ERP2", "f6-05" : "Detectors", "f6-05-01" : "Liquid Leakage Sensor", "f6-10" : "Mechanical Handle", "f6-10-00" : "Window Handle", "f6-10-01" : "Window Handle ERP2", "d5-00" : "Contacts and Switches", "d5-00-01" : "Single Input Contact", "a5-02" : "Temperature Sensor", "a5-02-01" : "Temperature Sensor Range -40°C to 0°C", "a5-02-02" : "Temperature Sensor Range -30°C to +10°C", "a5-02-03" : "Temperature Sensor Range -20°C to +20°C", "a5-02-04" : "Temperature Sensor Range -10°C to +30°C", "a5-02-05" : "Temperature Sensor Range 0°C to +40°C", "a5-02-06" : "Temperature Sensor Range +10°C to +50°C", "a5-02-07" : "Temperature Sensor Range +20°C to +60°C", "a5-02-08" : "Temperature Sensor Range +30°C to +70°C", "a5-02-09" : "Temperature Sensor Range +40°C to +80°C", "a5-02-0a" : "Temperature Sensor Range +50°C to +90°C", "a5-02-0b" : "Temperature Sensor Range +60°C to +100°C", "a5-02-10" : "Temperature Sensor Range -60°C to +20°C", "a5-02-11" : "Temperature Sensor Range -50°C to +30°C", "a5-02-12" : "Temperature Sensor Range -40°C to +40°C", "a5-02-13" : "Temperature Sensor Range -30°C to +50°C", "a5-02-14" : "Temperature Sensor Range -20°C to +60°C", "a5-02-15" : "Temperature Sensor Range -10°C to +70°C", "a5-02-16" : "Temperature Sensor Range 0°C to +80°C", "a5-02-17" : "Temperature Sensor Range +10°C to +90°C", "a5-02-18" : "Temperature Sensor Range +20°C to +100°C", "a5-02-19" : "Temperature Sensor Range +30°C to +110°C", "a5-02-1a" : "Temperature Sensor Range +40°C to +120°C", "a5-02-1b" : "Temperature Sensor Range +50°C to +130°C", "a5-02-20" : "10 Bit Temperature Sensor Range -10°C to +41.2°C", "a5-02-30" : "10 Bit Temperature Sensor Range -40°C to +62.3°C", "a5-04" : "Temperature and Humidity Sensor", "a5-04-01" : "Range 0°C to +40°C and 0% to 100%", "a5-04-02" : "Range -20°C to +60°C (10 Bit) and 0% to 100%", "a5-04-03" : "Range -20°C to +60°C (10 Bit) and 0% to 100%", "a5-05" : "Barometric Sensor", "a5-05-01" : "Range 500 to 1150 hPa", "a5-06" : "Light Sensors", "a5-06-01" : "Range 300lx to 60000lx", "a5-06-02" : "Range 0lx to 1020lx", "a5-06-03" : "Range 0lx to 1000lx (10 Bit, 1-Lux resolution)", "a5-07" : "Occupancy Sensor", "a5-07-01" : "Occupancy with Supply Voltage Monitor", "a5-07-02" : "Occupancy with Supply Voltage Monitor", "a5-07-03" : "Occupancy with Supply Voltage Monitor and Illumination (10 Bit)", "a5-08" : "Light, Temperature and Occupancy Sensor", "a5-08-01" : "Range 0lx to 510lx, 0°C to +51°C and Occupancy Button", "a5-08-02" : "Range 0lx to 1020lx, 0°C to +51°C and Occupancy Button", "a5-08-03" : "Range 0lx to 1530lx, -30°C to +50°C and Occupancy Button", "a5-09" : "Gas Sensors", "a5-09-02" : "CO-Sensor 0ppm to 1020ppm", "a5-09-04" : "CO2 Sensor", "a5-09-05" : "VOC Sensor", "a5-09-06" : "Radon Sensor", "a5-09-07" : "Particle Sensor", "a5-09-08" : "Pure CO2 Sensor", "a5-09-09" : "CPure CO2 Sensor with Power Failure Detection", "a5-10" : "Room Operating Panel", "a5-10-01" : "Temperature Sensor, Set Point, Fan Speed and Occupancy Control", "a5-10-02" : "Temperature Sensor, Set Point, Fan Speed and Day/Night Control", "a5-10-03" : "Temperature Sensor, Set Point Control", "a5-10-04" : "Temperature Sensor, Set Point and Fan Speed Control", "a5-10-05" : "Temperature Sensor, Set Point and Occupancy Control", "a5-10-06" : "Temperature Sensor, Set Point and Day/Night Control", "a5-10-07" : "Temperature Sensor and Fan Speed Control", "a5-10-08" : "Temperature Sensor, Fan Speed and Occupancy Control", "a5-10-09" : "Temperature Sensor, Fan Speed and Day/Night Control", "a5-10-0a" : "Temperature Sensor, Set Point Adjust and Single Input Contact", "a5-10-0b" : "Temperature Sensor and Single Input Contact", "a5-10-0c" : "Temperature Sensor and Occupancy Control", "a5-10-0d" : "Temperature Sensor and Day/Night Control", "a5-10-10" : "Temperatur and Humidity Sensor, Set Point and Occupancy Control", "a5-10-11" : "Temperatur and Humidity Sensor, Set Point and Day/Night Control", "a5-10-12" : "Temperatur and Humidity Sensor and Set Point Control", "a5-10-13" : "Temperatur and Humidity Sensor and Occupancy Control", "a5-10-14" : "Temperatur and Humidity Sensor and Day/Night Control", "a5-10-15" : "10 Bit Temperature Sensor, 6 Bit Set Point Control", "a5-10-16" : "10 Bit Temperature Sensor, 6 Bit Set Point and Occupancy Control", "a5-10-17" : "10 Bit Temperature Sensor and Occupancy Control", "a5-10-18" : "Temperature and Illumination Sensor, Set Point, Fan Speed and Occupancy Control", "a5-10-19" : "Temperature and Humidity Sensor, Set Point, Fan Speed and Occupancy Control", "a5-10-1a" : "Temeprature Sensor, Set Point, Fan Speed and Occupancy Control and Supply Voltage Monitor", "a5-10-1b" : "Temperature and Illumination Sensor, Fans Speed and Occupancy Control, Supply Voltage Monitor", "a5-10-1c" : "Temperature and Illumination Sensor, Illumination Set Point, Fans Speed and Occupancy Control", "a5-10-1d" : "Temperature and Humidity Sensor, Humidity Set Point, Fans Speed and Occupancy Control", "a5-10-1f" : "Temperature Sensor, Set Point, Fans Speed, Occupancy and Unoccupancy Control", "a5-10-20" : "Temperature Sensor, Set Point Control with Special Heating States", "a5-10-21" : "Temperature and Humidity Sensor, Set Point Control with Special Heating States", "a5-11" : "Controller Status", "a5-11-01" : "Lighting Controller Status", "a5-11-02" : "Temperature Controller Status", "a5-11-03" : "Blind Status", "a5-11-04" : "Extended Lighting Controller Status", "a5-12" : "Automated meter Reading (AMR)", "a5-12-00" : "Counter", "a5-12-01" : "Electricity", "a5-12-02" : "Gas", "a5-12-03" : "Water", "a5-12-04" : "Temperature and Load Sensor", "a5-12-05" : "Temperature and Container Sensor", "a5-13" : "Environmental Application", "a5-13-01" : "Weather Station", "a5-13-02" : "Sun Intensity", "a5-13-03" : "Date Exchange", "a5-13-04" : "Time and Day Exchange", "a5-13-05" : "Direction Exchange", "a5-13-06" : "Sun Intensity", "a5-13-10" : "Sun Position and Radiation", "a5-14" : "Multi-Func Sensor", "a5-14-01" : "Single Input Contact (Window/Door), Supply Voltage Monitor", "a5-14-02" : "Single Input Contact (Window/Door), Supply Voltage Monitor and Illumination Sensor", "a5-14-03" : "Single Input Contact (Window/Door), Supply Voltage Monitor and Vibration Sensor", "a5-14-04" : "Single Input Contact (Window/Door), Supply Voltage Monitor, Vibration and Illumination Sensor", "a5-14-05" : "Vibration/Tilt Sensor, Supply Voltage Monitor", "a5-14-06" : "Vibration/Tilt and Illumination Sensor, Supply Voltage Monitor", "a5-20" : "HVAC Components", "a5-20-01" : "Battery Powerd Actuator (BI-DIR)", "a5-20-02" : "Basic Actuator (BI-DIR)", "a5-20-03" : "Line Powerd Actuator (BI-DIR)", "a5-20-04" : "Heating Radiator Valve Actuating Drive with Feed and Room Temperature Measurement, Local Set Point Control and Display (BI-DIR)", "a5-20-10" : "Generic HVAC Interface (BI-DIR)", "a5-20-11" : "Generic HVAC Interface - Error Controll (BI-DIR)", "a5-20-12" : "Temperature Controlle Input", "a5-30" : "Digital Input", "a5-30-01" : "Single Input Contact, Battery Monitor", "a5-30-02" : "Singel Input Contact", "a5-30-03" : "4 Digital Inputs, Wake and Tmeperatur Sensor", "a5-30-04" : "3 Digital Inpute, 1 Digital Input 8 Bits", "a5-37" : "Energy Management", "a5-37-01" : "Demand Response", "a5-38" : "Central Command", "a5-38-08" : "Gateway", "a5-38-09" : "Extended Lighting Controll", "a5-3F" : "Universal", "a5-3f-00" : "Radio Link test (Bi-DIR)" }