UNPKG

node-enocean-ts

Version:

Typescript full implementation of the enocean protocol (ESP3 + EEP2.6)

153 lines 8.64 kB
"use strict"; Object.defineProperty(exports, "__esModule", { value: true }); exports.default = { "f6-02": "Rocker Switch, 2 Rocker", "f6-02-01": "Light and Blind Control - Application Style 1", "f6-02-02": "Light and Blind Control - Application Style 1", "f6-02-03": "Light Control - Application Style 1", "f6-02-04": "Light and Blind Control ERP2", "f6-03": "Rocker Switch 4 Rocker", "f6-03-01": "Light and Blind Control - Application Style 1", "f6-03-02": "Light and Blind Control - Application Style 2", "f6-04": "Position Switch, Home and Office Application", "f6-04-01": "Key Card Activation Switch", "f6-04-02": "Key Card Activation Switch ERP2", "f6-05": "Detectors", "f6-05-01": "Liquid Leakage Sensor", "f6-10": "Mechanical Handle", "f6-10-00": "Window Handle", "f6-10-01": "Window Handle ERP2", "d5-00": "Contacts and Switches", "d5-00-01": "Single Input Contact", "a5-02": "Temperature Sensor", "a5-02-01": "Temperature Sensor Range -40°C to 0°C", "a5-02-02": "Temperature Sensor Range -30°C to +10°C", "a5-02-03": "Temperature Sensor Range -20°C to +20°C", "a5-02-04": "Temperature Sensor Range -10°C to +30°C", "a5-02-05": "Temperature Sensor Range 0°C to +40°C", "a5-02-06": "Temperature Sensor Range +10°C to +50°C", "a5-02-07": "Temperature Sensor Range +20°C to +60°C", "a5-02-08": "Temperature Sensor Range +30°C to +70°C", "a5-02-09": "Temperature Sensor Range +40°C to +80°C", "a5-02-0a": "Temperature Sensor Range +50°C to +90°C", "a5-02-0b": "Temperature Sensor Range +60°C to +100°C", "a5-02-10": "Temperature Sensor Range -60°C to +20°C", "a5-02-11": "Temperature Sensor Range -50°C to +30°C", "a5-02-12": "Temperature Sensor Range -40°C to +40°C", "a5-02-13": "Temperature Sensor Range -30°C to +50°C", "a5-02-14": "Temperature Sensor Range -20°C to +60°C", "a5-02-15": "Temperature Sensor Range -10°C to +70°C", "a5-02-16": "Temperature Sensor Range 0°C to +80°C", "a5-02-17": "Temperature Sensor Range +10°C to +90°C", "a5-02-18": "Temperature Sensor Range +20°C to +100°C", "a5-02-19": "Temperature Sensor Range +30°C to +110°C", "a5-02-1a": "Temperature Sensor Range +40°C to +120°C", "a5-02-1b": "Temperature Sensor Range +50°C to +130°C", "a5-02-20": "10 Bit Temperature Sensor Range -10°C to +41.2°C", "a5-02-30": "10 Bit Temperature Sensor Range -40°C to +62.3°C", "a5-04": "Temperature and Humidity Sensor", "a5-04-01": "Range 0°C to +40°C and 0% to 100%", "a5-04-02": "Range -20°C to +60°C (10 Bit) and 0% to 100%", "a5-04-03": "Range -20°C to +60°C (10 Bit) and 0% to 100%", "a5-05": "Barometric Sensor", "a5-05-01": "Range 500 to 1150 hPa", "a5-06": "Light Sensors", "a5-06-01": "Range 300lx to 60000lx", "a5-06-02": "Range 0lx to 1020lx", "a5-06-03": "Range 0lx to 1000lx (10 Bit, 1-Lux resolution)", "a5-07": "Occupancy Sensor", "a5-07-01": "Occupancy with Supply Voltage Monitor", "a5-07-02": "Occupancy with Supply Voltage Monitor", "a5-07-03": "Occupancy with Supply Voltage Monitor and Illumination (10 Bit)", "a5-08": "Light, Temperature and Occupancy Sensor", "a5-08-01": "Range 0lx to 510lx, 0°C to +51°C and Occupancy Button", "a5-08-02": "Range 0lx to 1020lx, 0°C to +51°C and Occupancy Button", "a5-08-03": "Range 0lx to 1530lx, -30°C to +50°C and Occupancy Button", "a5-09": "Gas Sensors", "a5-09-02": "CO-Sensor 0ppm to 1020ppm", "a5-09-04": "CO2 Sensor", "a5-09-05": "VOC Sensor", "a5-09-06": "Radon Sensor", "a5-09-07": "Particle Sensor", "a5-09-08": "Pure CO2 Sensor", "a5-09-09": "CPure CO2 Sensor with Power Failure Detection", "a5-10": "Room Operating Panel", "a5-10-01": "Temperature Sensor, Set Point, Fan Speed and Occupancy Control", "a5-10-02": "Temperature Sensor, Set Point, Fan Speed and Day/Night Control", "a5-10-03": "Temperature Sensor, Set Point Control", "a5-10-04": "Temperature Sensor, Set Point and Fan Speed Control", "a5-10-05": "Temperature Sensor, Set Point and Occupancy Control", "a5-10-06": "Temperature Sensor, Set Point and Day/Night Control", "a5-10-07": "Temperature Sensor and Fan Speed Control", "a5-10-08": "Temperature Sensor, Fan Speed and Occupancy Control", "a5-10-09": "Temperature Sensor, Fan Speed and Day/Night Control", "a5-10-0a": "Temperature Sensor, Set Point Adjust and Single Input Contact", "a5-10-0b": "Temperature Sensor and Single Input Contact", "a5-10-0c": "Temperature Sensor and Occupancy Control", "a5-10-0d": "Temperature Sensor and Day/Night Control", "a5-10-10": "Temperatur and Humidity Sensor, Set Point and Occupancy Control", "a5-10-11": "Temperatur and Humidity Sensor, Set Point and Day/Night Control", "a5-10-12": "Temperatur and Humidity Sensor and Set Point Control", "a5-10-13": "Temperatur and Humidity Sensor and Occupancy Control", "a5-10-14": "Temperatur and Humidity Sensor and Day/Night Control", "a5-10-15": "10 Bit Temperature Sensor, 6 Bit Set Point Control", "a5-10-16": "10 Bit Temperature Sensor, 6 Bit Set Point and Occupancy Control", "a5-10-17": "10 Bit Temperature Sensor and Occupancy Control", "a5-10-18": "Temperature and Illumination Sensor, Set Point, Fan Speed and Occupancy Control", "a5-10-19": "Temperature and Humidity Sensor, Set Point, Fan Speed and Occupancy Control", "a5-10-1a": "Temeprature Sensor, Set Point, Fan Speed and Occupancy Control and Supply Voltage Monitor", "a5-10-1b": "Temperature and Illumination Sensor, Fans Speed and Occupancy Control, Supply Voltage Monitor", "a5-10-1c": "Temperature and Illumination Sensor, Illumination Set Point, Fans Speed and Occupancy Control", "a5-10-1d": "Temperature and Humidity Sensor, Humidity Set Point, Fans Speed and Occupancy Control", "a5-10-1f": "Temperature Sensor, Set Point, Fans Speed, Occupancy and Unoccupancy Control", "a5-10-20": "Temperature Sensor, Set Point Control with Special Heating States", "a5-10-21": "Temperature and Humidity Sensor, Set Point Control with Special Heating States", "a5-11": "Controller Status", "a5-11-01": "Lighting Controller Status", "a5-11-02": "Temperature Controller Status", "a5-11-03": "Blind Status", "a5-11-04": "Extended Lighting Controller Status", "a5-12": "Automated meter Reading (AMR)", "a5-12-00": "Counter", "a5-12-01": "Electricity", "a5-12-02": "Gas", "a5-12-03": "Water", "a5-12-04": "Temperature and Load Sensor", "a5-12-05": "Temperature and Container Sensor", "a5-13": "Environmental Application", "a5-13-01": "Weather Station", "a5-13-02": "Sun Intensity", "a5-13-03": "Date Exchange", "a5-13-04": "Time and Day Exchange", "a5-13-05": "Direction Exchange", "a5-13-06": "Sun Intensity", "a5-13-10": "Sun Position and Radiation", "a5-14": "Multi-Func Sensor", "a5-14-01": "Single Input Contact (Window/Door), Supply Voltage Monitor", "a5-14-02": "Single Input Contact (Window/Door), Supply Voltage Monitor and Illumination Sensor", "a5-14-03": "Single Input Contact (Window/Door), Supply Voltage Monitor and Vibration Sensor", "a5-14-04": "Single Input Contact (Window/Door), Supply Voltage Monitor, Vibration and Illumination Sensor", "a5-14-05": "Vibration/Tilt Sensor, Supply Voltage Monitor", "a5-14-06": "Vibration/Tilt and Illumination Sensor, Supply Voltage Monitor", "a5-20": "HVAC Components", "a5-20-01": "Battery Powerd Actuator (BI-DIR)", "a5-20-02": "Basic Actuator (BI-DIR)", "a5-20-03": "Line Powerd Actuator (BI-DIR)", "a5-20-04": "Heating Radiator Valve Actuating Drive with Feed and Room Temperature Measurement, Local Set Point Control and Display (BI-DIR)", "a5-20-10": "Generic HVAC Interface (BI-DIR)", "a5-20-11": "Generic HVAC Interface - Error Controll (BI-DIR)", "a5-20-12": "Temperature Controlle Input", "a5-30": "Digital Input", "a5-30-01": "Single Input Contact, Battery Monitor", "a5-30-02": "Singel Input Contact", "a5-30-03": "4 Digital Inputs, Wake and Tmeperatur Sensor", "a5-30-04": "3 Digital Inpute, 1 Digital Input 8 Bits", "a5-37": "Energy Management", "a5-37-01": "Demand Response", "a5-38": "Central Command", "a5-38-08": "Gateway", "a5-38-09": "Extended Lighting Controll", "a5-3F": "Universal", "a5-3f-00": "Radio Link test (Bi-DIR)" }; //# sourceMappingURL=eepDesc.js.map