Modbus RTU over Web Serial and Node.js SerialPort

233 lines (206 loc) 8.21 kB
// src/types/client.d.ts import { RegisterType, ModbusFunctionCode } from '../constants/constants.js'; import { LogContext as LoggerContext } from '../logger.js'; import { Transport, ModbusClientOptions, ConvertRegisterOptions, ReadCoilsResponse, ReadDiscreteInputsResponse, WriteSingleCoilResponse, WriteMultipleCoilsResponse, WriteSingleRegisterResponse, WriteMultipleRegistersResponse, ReportSlaveIdResponse, ReadDeviceIdentificationResponse, ReadFileLengthResponse, OpenFileResponse, CloseFileResponse, RestartControllerResponse, GetControllerTimeResponse, SetControllerTimeResponse, ConvertedRegisters, ControllerTime, } from './modbus-types.js'; declare class ModbusClient { /** * Creates a new Modbus client instance. * @param transport - The transport interface for Modbus communication. * @param slaveId - The slave ID (1–255, default: 1). * @param options - Configuration options for the client. */ constructor(transport: Transport, slaveId?: number, options?: ModbusClientOptions); /** * Включает логгер ModbusClient. * @param level - Уровень логирования (по умолчанию 'info'). */ enableLogger(level?: 'trace' | 'debug' | 'info' | 'warn' | 'error'): void; /** * Отключает логгер ModbusClient (устанавливает уровень 'error'). */ disableLogger(): void; /** * Устанавливает контекст для логгера (slaveId, functionCode и т.д.). * @param context - Контекст для логгера. */ setLoggerContext(context: LoggerContext): void; /** * Establishes a connection to the Modbus transport. * Logs the connection status upon successful connection. */ connect(): Promise<void>; /** * Closes the connection to the Modbus transport. * Logs the disconnection status upon successful disconnection. */ disconnect(): Promise<void>; /** * Sets the slave ID for the Modbus client. * @param slaveId - The slave ID (1–255). */ setSlaveId(slaveId: number): void; // --- Public Modbus Methods --- /** * Reads holding registers from the Modbus device. * @param startAddress - The starting address of the registers to read (0–65535). * @param quantity - The number of registers to read (1–125 for Modbus standard). * @param options - The options for the read operation (e.g., register type). * @returns The converted registers based on the specified type. */ readHoldingRegisters<T extends RegisterType>( startAddress: number, quantity: number, options?: ConvertRegisterOptions ): Promise<ConvertedRegisters<T>>; /** * Reads input registers from the Modbus device. * @param startAddress - The starting address of the registers to read (0–65535). * @param quantity - The number of registers to read (1–125 for Modbus standard). * @param options - The options for the read operation (e.g., register type). * @returns The converted registers based on the specified type. */ readInputRegisters<T extends RegisterType>( startAddress: number, quantity: number, options?: ConvertRegisterOptions ): Promise<ConvertedRegisters<T>>; /** * Writes a single register to the Modbus device. * @param address - The address of the register to write (0–65535). * @param value - The value to write to the register (0–65535). * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ writeSingleRegister( address: number, value: number, timeout?: number ): Promise<WriteSingleRegisterResponse>; /** * Writes multiple registers to the Modbus device. * @param startAddress - The starting address of the registers to write (0–65535). * @param values - The values to write to the registers (each 0–65535). * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ writeMultipleRegisters( startAddress: number, values: number[], timeout?: number ): Promise<WriteMultipleRegistersResponse>; /** * Reads coils from the Modbus device. * @param startAddress - The starting address of the coils to read (0–65535). * @param quantity - The number of coils to read (1–2000 for Modbus standard). * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ readCoils(startAddress: number, quantity: number, timeout?: number): Promise<ReadCoilsResponse>; /** * Reads discrete inputs from the Modbus device. * @param startAddress - The starting address of the discrete inputs to read (0–65535). * @param quantity - The number of discrete inputs to read (1–2000 for Modbus standard). * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ readDiscreteInputs( startAddress: number, quantity: number, timeout?: number ): Promise<ReadDiscreteInputsResponse>; /** * Writes a single coil to the Modbus device. * @param address - The address of the coil to write (0–65535). * @param value - The value to write to the coil (boolean or 0/1). * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ writeSingleCoil( address: number, value: boolean | number, timeout?: number ): Promise<WriteSingleCoilResponse>; /** * Writes multiple coils to the Modbus device. * @param startAddress - The starting address of the coils to write (0–65535). * @param values - The values to write to the coils. * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ writeMultipleCoils( startAddress: number, values: boolean[], timeout?: number ): Promise<WriteMultipleCoilsResponse>; /** * Reports the slave ID of the Modbus device. * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ reportSlaveId(timeout?: number): Promise<ReportSlaveIdResponse>; /** * Reads the device identification from the Modbus device. * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ readDeviceIdentification(timeout?: number): Promise<ReadDeviceIdentificationResponse>; /** * Reads the file length from the Modbus device (SGM130). * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ readFileLength(timeout?: number): Promise<ReadFileLengthResponse>; /** * Opens a file on the Modbus device (SGM130). * @param filename - The name of the file to open. * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ openFile(filename: string, timeout?: number): Promise<OpenFileResponse>; /** * Closes a file on the Modbus device (SGM130). * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ closeFile(timeout?: number): Promise<CloseFileResponse>; /** * Restarts the controller on the Modbus device (SGM130). * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ restartController(timeout?: number): Promise<RestartControllerResponse>; /** * Gets the controller time from the Modbus device (SGM130). * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ getControllerTime(timeout?: number): Promise<GetControllerTimeResponse>; /** * Sets the controller time on the Modbus device (SGM130). * @param datetime - The datetime to set on the controller. * @param timeout - The timeout in milliseconds (optional). * @returns The response from the Modbus device. */ setControllerTime(datetime: Date, timeout?: number): Promise<SetControllerTimeResponse>; } export default ModbusClient;