UNPKG

knxultimate

Version:

KNX IP protocol implementation for Node. This is the ENGINE of Node-Red KNX-Ultimate node.

90 lines 3.73 kB
"use strict"; Object.defineProperty(exports, "__esModule", { value: true }); const KnxLog_1 = require("../KnxLog"); const utils_1 = require("../utils"); const logger = (0, KnxLog_1.module)('DPT213'); const config = { id: 'DPT213', formatAPDU(value) { const apdu_data = Buffer.alloc(8); if (typeof value === 'object' && (0, utils_1.hasProp)(value, 'Comfort') && value.Comfort >= -272 && value.Comfort <= 655.34 && (0, utils_1.hasProp)(value, 'Standby') && value.Standby >= -272 && value.Standby <= 655.34 && (0, utils_1.hasProp)(value, 'Economy') && value.Economy >= -272 && value.Economy <= 655.34 && (0, utils_1.hasProp)(value, 'BuildingProtection') && value.BuildingProtection >= -272 && value.BuildingProtection <= 655.34) { const ArrComfort = (0, utils_1.getHex)(value.Comfort); apdu_data[0] = ArrComfort[0]; apdu_data[1] = ArrComfort[1]; const ArrStandby = (0, utils_1.getHex)(value.Standby); apdu_data[2] = ArrStandby[0]; apdu_data[3] = ArrStandby[1]; const ArrEconomy = (0, utils_1.getHex)(value.Economy); apdu_data[4] = ArrEconomy[0]; apdu_data[5] = ArrEconomy[1]; const ArrBuildingProtection = (0, utils_1.getHex)(value.BuildingProtection); apdu_data[6] = ArrBuildingProtection[0]; apdu_data[7] = ArrBuildingProtection[1]; return apdu_data; } logger.error('Must supply a payload like, for example: {Comfort:21, Standby:20, Economy:14, BuildingProtection:8}'); return null; }, fromBuffer(buf) { if (buf.length !== 8) { logger.warn('fromBuffer: buf should be 4x2 bytes long (got %d bytes)', buf.length); return null; } const nComfort = (0, utils_1.getFloat)(buf[0], buf[1]); const nStandby = (0, utils_1.getFloat)(buf[2], buf[3]); const nEconomy = (0, utils_1.getFloat)(buf[4], buf[5]); const nbProt = (0, utils_1.getFloat)(buf[6], buf[7]); return { Comfort: nComfort, Standby: nStandby, Economy: nEconomy, BuildingProtection: nbProt, }; }, basetype: { bitlength: 4 * 16, valuetype: 'basic', desc: '4x 16-Bit Signed Value', help: `// Sample of 213.100. // Set the temperatures between -272°C and 655.34°C with 0,02°C of resolution. // These 4 property names, are valid for 213.101, 213.102 etc... as well. // For example, for 213.101, LegioProtect is the "Comfort" property, Normal is "Standby", etc... msg.payload = {Comfort:21.4, Standby:20, Economy:18.2, BuildingProtection:-1}; return msg;`, helplink: 'https://github.com/Supergiovane/node-red-contrib-knx-ultimate/wiki/-Sample---DPT213', }, subtypes: { 100: { desc: 'DPT_TempRoomSetpSet[4]', name: 'Room temperature setpoint (Comfort, Standby, Economy, Building protection)', unit: '°C', range: [-272, 655.34], }, 101: { desc: 'DPT_TempDHWSetpSet[4]', name: 'Room temperature setpoint DHW (LegioProtect, Normal, Reduced, Off/FrostProtect)', unit: '°C', range: [-272, 655.34], }, 102: { desc: 'DPT_TempRoomSetpSetShift[4]', name: 'Room temperature setpoint shift (Comfort, Standby, Economy, Building protection)', unit: '°C', range: [-272, 655.34], }, }, }; exports.default = config; //# sourceMappingURL=dpt213.js.map