isocontainer
Version:
Container size & type validator
127 lines (126 loc) • 5.5 kB
JSON
{
"designation": {
"plain": {
"0": "General Purpose Container without Ventilation",
"1": "General Purpose Container with Ventilation",
"2": "Thermal Container",
"3": "Thermal Container",
"4": "Thermal Container",
"5": "Open-Top Container",
"6": "Platform (Container)",
"7": "Tank Container",
"8": "Dry Bulk Container",
"9": "Air/Surface Container",
"G": "General Purpose Container without Ventilation",
"T": "Tank Container",
"V": "General Purpose Container with Ventilation",
"B": "Dry Bulk Container",
"S": "Named Cargo Container",
"R": "Thermal Container",
"H": "Thermal Container",
"U": "Open-Top Container",
"P": "Platform (Container)",
"K": "Pressurized Tank Container",
"N": "Pressurized and Non-Pressurized Tank Container (Dry)",
"A": "Air/Surface Container"
},
"simplified": {
"0": "General Purpose",
"1": "General Purpose with Ventilation",
"2": "Thermal",
"3": "Thermal",
"4": "Thermal",
"5": "Open-Top",
"6": "Platform",
"7": "Tank",
"8": "Dry Bulk",
"9": "Air/Surface",
"G": "General Purpose",
"T": "Tank",
"V": "General Purpose with Ventilation",
"B": "Dry Bulk",
"S": "Named Cargo",
"R": "Thermal",
"H": "Thermal",
"U": "Open-Top",
"P": "Platform",
"K": "Pressurized Tank",
"N": "Pressurized/Non-Pressurized Tank",
"A": "Air/Surface"
}
},
"type": {
"G0": "Openings at one or both ends",
"G1": "Passive vents at upper part of cargo space",
"G2": "Opening(s) at one or both ends + full openings on one or both sides",
"G3": "Openings at one or both ends + partial openings on one or both sides",
"G9": "With bulk capabilities",
"V0": "Non-mechanical, vents at lower and upper parts of cargo space",
"V2": "Mechanical ventilation system located internally",
"V4": "Mechanical ventilation system located externally",
"B0": "Closed",
"B1": "Airtight",
"B3": "Rear discharge/cat flap type",
"B4": "Rear discharge/full width opening",
"B5": "Rear discharge/full width fixed ",
"B8": "Front discharge/full width ",
"B9": "Side discharge",
"S0": "Livestock carrier",
"S1": "Automobile carrier",
"S2": "Live fish carrier",
"S4": "Generator",
"R0": "Mechanically refrigerated",
"R1": "Mechanically refrigerated and heated",
"R2": "Self-powered mechanically refrigerated",
"R3": "Self-powered mechanically refrigerated and heated",
"H0": "Refrigerated and/or heated with removable equipment located externally, heat transfer coefficient K=0.4W/m2.K",
"H1": "Refrigerated and/or heated with removable equipment located internally",
"H2": "Refrigerated and/or heated with removable equipment located externally, heat transfer coefficient K=0.7W/m2.K",
"H5": "Insulated, heat transfer coefficient K=0.4W/m2.K",
"H6": "Insulated, heat transfer coefficient K=0.7W/m2.K",
"U0": "Opening(s) at one or both ends",
"U1": "Opening(s) at one or both ends + removable top member(s) in end frame(s)",
"U2": "Opening(s) at one or both ends + opening(s) at one or both sides",
"U3": "Opening(s) at one or both ends + opening(s) at one or both sides + removable top member(s) in end frames",
"U4": "Opening(s) at one or both ends + partial opening on one side and full opening on the other side",
"U6": "Open topped container with removeable hard top",
"P0": "Platform (container) ",
"P1": "Two complete and fixed ends",
"P2": "Fixed posts, either free-standing or with removable top member",
"P3": "Folding complete end structure",
"P4": "Folding posts, either free-standing or with removable top member",
"P5": "Open top, open ends (skeletal)",
"P6": "Folding complete end structure",
"P7": "Car carrier",
"P8": "Timber / Pipe carrier",
"P9": "Coil carrier",
"T0": "Non-hazardous liquids, minimum pressure 45 kPa",
"T1": "Non-hazardous liquids, minimum pressure 150 kPa",
"T2": "Non-hazardous liquids, minimum pressure 265 kPa",
"T3": "Dangerous liquids, minimum pressure 150 kPa",
"T4": "Dangerous liquids, minimum pressure 265 kPa",
"T5": "Dangerous liquids, minimum pressure 400 kPa",
"T6": "Dangerous liquids, minimum pressure 600 kPa",
"T7": "Gases, minimum pressure 910 kPa",
"T8": "Gases, minimum pressure 2200 kPa",
"T9": "Gases, minimum pressure (to be decided)",
"K0": "Liquid tank non-regulated goods",
"K1": "Liquid tank dangerous goods ≤ 2,65 barc pressure",
"K2": "Liquid tank dangerous goods >2,65 barc and ≤ 10 barc pressure",
"K3": "Liquid tank dangerous goods > 10 barc high pressure",
"K4": "Liquid tank non regulated goods requiring power supply ",
"K5": "Liquid tank for dangerous goods ≤ 10 barc requiring power supply",
"K6": "Liquid tank for dangerous goods > 10 barc pressure requiring power supply",
"K7": "Cryogenic tank",
"K8": "Gas tank",
"N0": "Hopper type vertical discharge",
"N1": "Hopper type rear discharge",
"N3": "Non pressurized rear discharge ",
"N4": "Non-pressurized side discharge",
"N5": "Non-pressurized tipping discharge",
"N7": "Pressurized rear discharge",
"N8": "Pressurized side discharge",
"N9": "Pressurized tipping discharge",
"A0": "Air/Surface (intermodal) container"
}
}