function checkConfig(config, log, version) {
const checkAPIOptions = {
legacy_api_enabled: config.advanced.legacy_api != false,
legacy_availability_payload_enabled: config.advanced.legacy_availability_payload != false,
device_legacy_enabled: config.device_options.legacy != false
};
const checkAPIOptionsOutput = {
payload_contains_not_json: config.advanced.output != 'attribute_and_json' && config.advanced.output != 'json'
};
if (version.startsWith('1.')) { // wird in version 2.x immer auf false gesetzt sein
if (Object.values(checkAPIOptions).filter((x) => x == true).length > 0) {
log.error('===================================================');
log.error('===================================================');
if (checkAPIOptions.legacy_api_enabled == true) {
log.error('Legacy api is activated, so the adapter can not work correctly!!!');
log.error('Please add the following lines to your Zigbee2MQTT configuration.yaml:');
log.error('advanced:');
log.error(' legacy_api: false');
log.error('');
}
if (checkAPIOptions.legacy_availability_payload_enabled == true) {
log.error(
'Legacy Availability Payload is activated, thus the adapter cannot represent the availability of the devices!!!'
);
log.error('Please add the following lines to your Zigbee2MQTT configuration.yaml:');
log.error('advanced:');
log.error('legacy_availability_payload: false');
log.error('');
}
if (checkAPIOptions.device_legacy_enabled == true) {
log.error(
'Device Legacy Payload is activated, therefore the adapter may process the states of the devices correctly!!!'
);
log.error('Please add the following lines to your Zigbee2MQTT configuration.yaml:');
log.error('device_options:');
log.error(' legacy: false');
}
log.error('===================================================');
}
}
if (Object.values(checkAPIOptionsOutput).filter((x) => x == true).length > 0) {
if (checkAPIOptions.payload_contains_not_json == true ) {
log.error('===================================================');
log.error(
'MQTT output type must "attribute_and_json" or "json" , therefore the adapter may process the states of the devices correctly!!!'
);
log.error('Please add the following lines to your Zigbee2MQTT configuration.yaml:');
log.error('advanced:');
log.error(' output: json');
log.error('or');
log.error('advanced:');
log.error(' output: attribute_and_json');
log.error('');
log.error('===================================================');
}
}
}
module.exports = {
checkConfig: checkConfig,
};