UNPKG

iobroker.ecoflow-mqtt

Version:
412 lines (410 loc) 11.5 kB
const deviceStates = { emeters: { number: { currentL1: { min: 0, max: 100, unit_of_measurement: 'A', mult: 1, entity_type: 'sensor', device_class: 'current', name: 'Current L1', role: 'value', }, currentL2: { min: 0, max: 100, unit_of_measurement: 'A', mult: 1, entity_type: 'sensor', device_class: 'current', name: 'Current L2', role: 'value', }, currentL3: { min: 0, max: 100, unit_of_measurement: 'A', mult: 1, entity_type: 'sensor', device_class: 'current', name: 'Current L3', role: 'value', }, voltageL1: { min: 0, max: 250, unit_of_measurement: 'V', mult: 1, entity_type: 'sensor', device_class: 'voltage', name: 'Voltage L1', role: 'value', }, voltageL2: { min: 0, max: 250, unit_of_measurement: 'V', mult: 1, entity_type: 'sensor', device_class: 'voltage', name: 'Voltage L2', role: 'value', }, voltageL3: { min: 0, max: 250, unit_of_measurement: 'V', mult: 1, entity_type: 'sensor', device_class: 'voltage', name: 'Voltage L3', role: 'value', }, powerL1: { min: 0, max: 23000, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Power L1', role: 'value', }, powerL2: { min: 0, max: 23000, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Power L2', role: 'value', }, powerL3: { min: 0, max: 23000, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Power L3', role: 'value', }, pfL1: { min: 0, max: 1, unit_of_measurement: '', mult: 1, entity_type: 'sensor', device_class: 'power_factor', name: 'Powerfactor L1', role: 'value', subrole: 'none', }, pfL2: { min: 0, max: 1, unit_of_measurement: '', mult: 1, entity_type: 'sensor', device_class: 'power_factor', name: 'Powerfactor L2', role: 'value', subrole: 'none', }, pfL3: { min: 0, max: 1, unit_of_measurement: '', mult: 1, entity_type: 'sensor', device_class: 'power_factor', name: 'Powerfactor L3', role: 'value', subrole: 'none', }, totalL1: { min: 0, unit_of_measurement: 'kWh', mult: 0.001, entity_type: 'sensor', device_class: 'energy', name: 'Energy L1', state_class: 'total_increasing', role: 'value', }, totalL2: { min: 0, unit_of_measurement: 'kWh', mult: 0.001, entity_type: 'sensor', device_class: 'energy', name: 'Energy L2', state_class: 'total_increasing', role: 'value', }, totalL3: { min: 0, unit_of_measurement: 'kWh', mult: 0.001, entity_type: 'sensor', device_class: 'energy', name: 'Energy L3', state_class: 'total_increasing', role: 'value', }, total_returnedL1: { min: 0, unit_of_measurement: 'kWh', mult: 0.001, entity_type: 'sensor', device_class: 'energy', name: 'Energy returned L2', state_class: 'total_increasing', role: 'value', }, total_returnedL2: { min: 0, unit_of_measurement: 'kWh', mult: 0.001, entity_type: 'sensor', device_class: 'energy', name: 'Energy returned L2', state_class: 'total_increasing', role: 'value', }, total_returnedL3: { min: 0, unit_of_measurement: 'kWh', mult: 0.001, entity_type: 'sensor', device_class: 'energy', name: 'Energy returned L3', state_class: 'total_increasing', role: 'value', }, total_power: { min: 0, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Total power', role: 'value', }, }, }, communication: { diagnostic: { cloud_connected: { entity_type: 'text', entity_category: 'diagnostic', name: 'cloud connected', role: 'info', cloud_connected: { false: 'off', true: 'on', }, }, cloud_enabled: { entity_type: 'text', entity_category: 'diagnostic', name: 'cloud enabled', role: 'info', cloud_enabled: { false: 'off', true: 'on', }, }, mqtt_connected: { entity_type: 'text', entity_category: 'diagnostic', name: 'mqtt connected', role: 'info', mqtt_connected: { false: 'off', true: 'on', }, }, wifi_sta_connected: { entity_type: 'text', entity_category: 'diagnostic', name: 'wifi_sta connected', role: 'info', wifi_sta_connected: { false: 'off', true: 'on', }, }, }, }, action: { switch: { latestQuotas: { entity_type: 'switch', device_class: 'switch', role: 'switch', name: 'Get latest Quotas', payload_off: 'no trigger', payload_on: 'trigger', latestQuotas: { 0: 'no trigger', 1: 'trigger', }, }, }, }, info: { number: { msgCount: { min: 0, unit_of_measurement: '', mult: 1, entity_type: 'sensor', name: 'received MSG#', role: 'value', }, }, diagnostic: { status: { entity_type: 'text', entity_category: 'diagnostic', name: 'Status', role: 'info', status: { 0: 'offline', 1: 'online', }, }, }, }, }; const deviceStatesDict = { shelly3em: { emeters: { currentL1: { entity: 'number', }, currentL2: { entity: 'number', }, currentL3: { entity: 'number', }, voltageL1: { entity: 'number', }, voltageL2: { entity: 'number', }, voltageL3: { entity: 'number', }, powerL1: { entity: 'number', }, powerL2: { entity: 'number', }, powerL3: { entity: 'number', }, pfL1: { entity: 'number', }, pfL2: { entity: 'number', }, pfL3: { entity: 'number', }, totalL1: { entity: 'number', }, totalL2: { entity: 'number', }, totalL3: { entity: 'number', }, total_returnedL1: { entity: 'number', }, total_returnedL2: { entity: 'number', }, total_returnedL3: { entity: 'number', }, total_power: { entity: 'number', }, }, communication: { cloud_connected: { entity: 'diagnostic', }, cloud_enabled: { entity: 'diagnostic', }, mqtt_connected: { entity: 'diagnostic', }, wifi_sta_connected: { entity: 'diagnostic', }, }, action: { latestQuotas: { entity: 'switch', }, }, info: { msgCount: { entity: 'number' }, status: { entity: 'diagnostic', }, }, }, }; const deviceRanges = { shelly3em: { emeters: { number: { currentL1: { max: 100, }, currentL2: { max: 100, }, currentL3: { max: 100, }, }, }, }, }; const deviceCmd = { shelly3em: { action: { latestQuotas: { moduleType: 0, msg: { from: 'iOS', operateType: 'latestQuotas', id: '83154039', lang: 'de-de', params: {}, version: '1.0', }, }, }, }, }; module.exports = { deviceStates, deviceStatesDict, deviceRanges, deviceCmd, };