UNPKG

iobroker.ecoflow-mqtt

Version:
1,569 lines 84.3 kB
const deviceStates = { bmsMaster: { number: { f32ShowSoc: { min: 0, max: 100, unit_of_measurement: '%', mult: 1, entity_type: 'sensor', device_class: 'battery', name: 'SOC', role: 'value', }, designCap: { min: 0, max: 80000, unit_of_measurement: 'mAh', mult: 1, entity_type: 'sensor', name: 'Design capacity', entity_category: 'diagnostic', role: 'value', }, remainCap: { min: 0, max: 80000, unit_of_measurement: 'mAh', mult: 1, entity_type: 'sensor', name: 'Remaining capacity', role: 'value', }, temp: { min: 0, max: 80, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'Temperature', role: 'value', }, maxCellTemp: { min: 0, max: 80, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'Maximum cell temperature', role: 'value', }, vol: { min: 0, max: 60, unit_of_measurement: 'V', mult: 0.001, entity_type: 'sensor', device_class: 'voltage', name: 'Voltage', role: 'value', }, amp: { min: 0, max: 25, unit_of_measurement: 'A', mult: 0.001, entity_type: 'sensor', device_class: 'current', name: 'Current', role: 'value', }, outputWatts: { min: 0, max: 4000, unit_of_measurement: 'W', mult: 0.1, entity_type: 'sensor', device_class: 'power', name: 'Output power', role: 'value', }, soc: { min: 0, max: 100, unit_of_measurement: '%', mult: 1, entity_type: 'sensor', device_class: 'battery', name: 'Remaining battery percentage', role: 'value', }, minCellTemp: { min: 0, max: 80, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'Minimum cell temperature', role: 'value', }, maxMosTemp: { min: 0, max: 80, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'Maximum MOS temperature', role: 'value', }, tagChgAmp: { min: 0, max: 100, unit_of_measurement: 'A', mult: 0.0001, entity_type: 'sensor', device_class: 'current', name: 'Target charging current', entity_category: 'diagnostic', role: 'value', }, maxCellVol: { min: 0, max: 60, unit_of_measurement: 'V', mult: 0.001, entity_type: 'sensor', device_class: 'voltage', name: 'Maximum cell voltage', role: 'value', }, inputWatts: { min: 0, max: 4000, unit_of_measurement: 'W', mult: 0.1, entity_type: 'sensor', device_class: 'power', name: 'Input power', role: 'value', }, minMosTemp: { min: 0, max: 80, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'Minimum MOS temperature', role: 'value', }, remainTime: { min: 0, max: 143999, unit_of_measurement: 'min', mult: 1, entity_type: 'sensor', device_class: 'duration', name: 'Time remaining', entity_category: 'diagnostic', role: 'value', }, minCellVol: { min: 0, max: 60, unit_of_measurement: 'V', mult: 0.001, entity_type: 'sensor', device_class: 'voltage', name: 'Minimum cell voltage', role: 'value', }, fullCap: { min: 0, max: 80000, unit_of_measurement: 'mAh', mult: 1, entity_type: 'sensor', name: 'Full capacity', role: 'value', }, cycles: { min: 0, max: 6000, unit_of_measurement: '', mult: 1, entity_type: 'sensor', name: 'Number of cycles', role: 'value', }, }, string: { bmsFault: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'BMS permanent fault', }, soh: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Health status', }, sysVer: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'System version', }, bqSysStatReg: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'BQ hardware protection register', }, num: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'BMS number', }, openBmsIdx: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Battery pack enable state', }, }, diagnostic: { type: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'BMS type', type: { 1: 'Lithium battery', 2: 'Oil-powered', }, }, errCode: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Global error code', errCode: { 0: 'OK?', }, }, cellId: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Battery capacity type', cellId: { 1: '2.5 Ah per battery', 2: '2 Ah per battery', }, }, }, }, ems: { diagnostic: { chgCmd: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Charge switch', chgCmd: { 0: 'off', 1: 'on', 2: '2?', }, }, bmsWarningState: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'BMS warning state', bmsWarningState: { 0: 'no warning?', 1: 'hi_temp', 2: 'low_temp', 4: 'overload', 8: 'chg_flag', }, }, emsIsNormalFlag: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Energy storage state: 0: sleep; 1: normal', emsIsNormalFlag: { 0: 'sleep', 1: 'normal', }, }, bms0Online: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'BMS0 online signal', bms0Online: { 0: 'not online?', 1: 'HW online', 2: 'SW online', 3: 'HW-SW online', }, }, bms1Online: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'BMS1 online signal', bms1Online: { 0: 'not online?', 1: 'HW online', 2: 'SW online', 3: 'HW-SW online', }, }, dsgCmd: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Discharge switch', dsgCmd: { 0: 'off', 1: 'on', 2: '2?', }, }, chgState: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Charging state', chgState: { 0: 'disabled', 1: 'CC', 2: 'CV', 3: 'UPS', 4: 'PARA 0x55: Charging error', }, }, }, level: { minDsgSoc: { min: 0, max: 30, unit_of_measurement: '%', mult: 1, step: 1, entity_type: 'number', device_class: 'battery', role: 'level', name: 'Discharge lower limit', icon: 'mdi:battery-charging-10', }, minOpenOilEbSoc: { min: 0, max: 30, unit_of_measurement: '%', mult: 1, step: 1, entity_type: 'number', device_class: 'battery', role: 'level', name: 'The upper threshold of smart generator auto on Range: 0~100', }, maxChargeSoc: { min: 50, max: 100, unit_of_measurement: '%', mult: 1, step: 1, entity_type: 'number', device_class: 'battery', role: 'level', name: 'Charge upper limit', icon: 'mdi:battery-charging-90', }, maxCloseOilEbSoc: { min: 50, max: 100, unit_of_measurement: '%', mult: 1, step: 1, entity_type: 'number', device_class: 'battery', role: 'level', name: 'The lower threshold of smart generator auto off Range: 0~100', }, }, number: { paraVolMax: { min: 0, max: 60, unit_of_measurement: 'V', mult: 0.001, entity_type: 'sensor', device_class: 'voltage', name: 'Maximum parallel voltage', role: 'value', }, f32LcdShowSoc: { min: 0, max: 100, unit_of_measurement: '%', mult: 1, entity_type: 'sensor', device_class: 'battery', name: 'SOC on LCD', role: 'value', }, lcdShowSoc: { min: 0, max: 100, unit_of_measurement: '%', mult: 1, entity_type: 'sensor', device_class: 'battery', name: 'SOC on LCD', role: 'value', }, chgRemainTime: { min: 0, max: 143999, unit_of_measurement: 'min', mult: 1, entity_type: 'sensor', device_class: 'duration', name: 'Remaining charging time', role: 'value', icon: 'mdi:clock-start', }, paraVolMin: { min: 0, max: 60, unit_of_measurement: 'V', mult: 0.001, entity_type: 'sensor', device_class: 'voltage', name: 'Minimum parallel voltage', role: 'value', }, dsgRemainTime: { min: 0, max: 143999, unit_of_measurement: 'min', mult: 1, entity_type: 'sensor', device_class: 'duration', name: 'Remaining discharging time', role: 'value', icon: 'mdi:clock-start', }, chgVol: { min: 0, max: 150, unit_of_measurement: 'V', mult: 0.001, entity_type: 'sensor', device_class: 'voltage', name: 'Charging voltage', role: 'value', }, chgAmp: { min: 0, max: 100, unit_of_measurement: 'A', mult: 0.0001, entity_type: 'sensor', device_class: 'current', name: 'Charging current', role: 'value', }, }, string: { openBmsIdx: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Open BMS index', }, maxAvailableNum: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Maximum available quantity', }, bmsModel: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'BMS model', }, openUpsFlag: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'UPS mode enable flag', }, fanLevel: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Fan level', }, }, }, inv: { number: { dcInVol: { min: 0, max: 60, unit_of_measurement: 'V', mult: 0.001, entity_type: 'sensor', device_class: 'voltage', name: 'DC input voltage', role: 'value', }, dcInAmp: { min: 0, max: 13, unit_of_measurement: 'A', mult: 0.001, entity_type: 'sensor', device_class: 'current', name: 'DC input current', role: 'value', }, outputWatts: { min: 0, max: 4000, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Discharging power', role: 'value', }, dcInTemp: { min: 0, max: 80, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'DC temperature', role: 'value', }, invOutFreq: { min: 0, max: 62, unit_of_measurement: 'Hz', mult: 1, entity_type: 'sensor', device_class: 'frequency', name: 'Inverter output frequency', role: 'value', }, cfgFastChgWatts: { min: 200, max: 1200, unit_of_measurement: 'W', mult: 1, step: 100, entity_type: 'sensor', device_class: 'power', role: 'value', name: 'Maximum charging power for AC fast charging (W)', }, acInAmp: { min: 0, max: 13, unit_of_measurement: 'A', mult: 0.001, entity_type: 'sensor', device_class: 'current', name: 'Inverter input current', role: 'value', }, outTemp: { min: 0, max: 90, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'Inverter temperature', role: 'value', }, invOutVol: { min: 0, max: 250, unit_of_measurement: 'V', mult: 0.001, entity_type: 'sensor', device_class: 'voltage', name: 'Actual inverter output voltage', role: 'value', }, acInVol: { min: 0, max: 250, unit_of_measurement: 'V', mult: 0.001, entity_type: 'sensor', device_class: 'voltage', name: 'Inverter input voltage', role: 'value', }, inputWatts: { min: 0, max: 4000, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Charging power', role: 'value', }, acInFreq: { min: 0, max: 62, unit_of_measurement: 'Hz', mult: 1, entity_type: 'sensor', device_class: 'frequency', name: 'Inverter input frequency', role: 'value', }, invOutAmp: { min: 0, max: 13, unit_of_measurement: 'A', mult: 0.001, entity_type: 'sensor', device_class: 'current', name: 'Inverter output current', role: 'value', }, }, switch: { cfgAcWorkMode: { entity_type: 'switch', device_class: 'switch', role: 'switch', name: 'AC charging mode', payload_off: 'full power', payload_on: 'mute', cfgAcWorkMode: { 0: 'full power', 1: 'mute', }, }, cfgAcEnabled: { entity_type: 'switch', device_class: 'outlet', role: 'switch', name: 'AC discharge (INV) switch setting', payload_off: 'off', payload_on: 'on', cfgAcEnabled: { 0: 'off', 1: 'on', }, }, cfgAcXboost: { entity_type: 'switch', device_class: 'switch', role: 'switch', name: 'X-Boost switch', payload_off: 'off', payload_on: 'on', cfgAcXboost: { 0: 'off', 1: 'on', ff: 'ignored', }, }, }, string: { cfgAcOutVoltage: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Inverter output voltage (V): 0xffffffff: ignored', }, errCode: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Global error code', }, invType: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'PSDR model code', }, sysVer: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'System version', }, }, level: { cfgStandbyMin: { min: 0, max: 720, unit_of_measurement: 'min', mult: 1, entity_type: 'select', device_class: 'duration', select: ['Never', '30 min', '1 hr', '2 hr', '4 hr', '6 hr', '12 hr'], select_obj: { Never: 0, '30 min': 30, '1 hr': 60, '2 hr': 120, '4 hr': 240, '6 hr': 360, '12 hr': 720, }, states: { 0: 'Never', 30: '30 min', 60: '1 hr', 120: '2 hr', 240: '4 hr', 360: '6 hr', 720: '12 hr', }, role: 'level', subrole: 'timer', name: 'AC standby time /min 0 Never standby 720 Default value', }, cfgSlowChgWatts: { min: 200, max: 700, unit_of_measurement: 'W', mult: 1, step: 100, entity_type: 'number', device_class: 'power', role: 'level', name: 'Maximum charging power for AC slow charging (W)', }, }, diagnostic: { cfgAcOutFreq: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Inverter output frequency (Hz)', cfgAcOutFreq: { 1: '50 Hz', 2: '60 Hz', 255: 'ignored', }, }, chargerType: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Charger type', chargerType: { 0: 'no charging', 1: 'AC charging', 2: 'DC adapter charging', 3: 'solar charging', 4: 'CC', 5: 'BC', }, }, fanState: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Fan state', fanState: { 0: 'disabled', 1: 'Level 1', 2: 'Level 2', 3: 'Level 3', }, }, acDipSwitch: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'AC fast/slow charging dip switch', acDipSwitch: { 0: 'unknown', 1: 'fast charging mode', 2: 'slow charging mode', }, }, acPassByAutoEn: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'acPassByAutoEn', acPassByAutoEn: { 0: '0?', 1: '1?', }, }, chgPauseFlag: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'AC charging pause flag', chgPauseFlag: { 0: 'no pause?', 1: 'charging stopped', }, }, dischargeType: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Discharging type', dischargeType: { 0: 'no discharge?', 1: 'AC discharging', 2: 'PR', 3: 'BC', }, }, }, }, mppt: { number: { carOutVol: { min: 0, max: 15, unit_of_measurement: 'V', mult: 0.1, entity_type: 'sensor', device_class: 'voltage', name: 'Car charging output voltage', role: 'value', }, carTemp: { min: 0, max: 80, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'Car charging temperature', role: 'value', }, outWatts: { min: 0, max: 600, unit_of_measurement: 'W', mult: 0.1, entity_type: 'sensor', device_class: 'power', name: 'PV output power', role: 'value', }, carOutAmp: { min: 0, max: 13, unit_of_measurement: 'A', mult: 0.01, entity_type: 'sensor', device_class: 'current', name: 'Car charging output current', role: 'value', }, outAmp: { min: 0, max: 13, unit_of_measurement: 'A', mult: 0.01, entity_type: 'sensor', device_class: 'current', name: 'PV output current', role: 'value', }, dcdc12vWatts: { min: 0, max: 500, unit_of_measurement: 'W', mult: 0.1, entity_type: 'sensor', device_class: 'power', name: 'DC12V30A output power, which is valid only for DELTA Pro', role: 'value', }, inWatts: { min: 0, max: 500, unit_of_measurement: 'W', mult: 0.1, entity_type: 'sensor', device_class: 'power', name: 'PV input power', role: 'value', }, dcdc12vVol: { min: 0, max: 60, unit_of_measurement: 'V', mult: 0.1, entity_type: 'sensor', device_class: 'voltage', name: 'DC12V30A output voltage, which is valid only for DELTA Pro', role: 'value', }, inAmp: { min: 0, max: 13, unit_of_measurement: 'A', mult: 0.01, entity_type: 'sensor', device_class: 'current', name: 'PV input current', role: 'value', }, inVol: { min: 0, max: 65, unit_of_measurement: 'V', mult: 0.1, entity_type: 'sensor', device_class: 'voltage', name: 'PV input voltage', role: 'value', }, carOutWatts: { min: 0, max: 500, unit_of_measurement: 'W', mult: 0.1, entity_type: 'sensor', device_class: 'power', name: 'Car charging output power', role: 'value', }, mpptTemp: { min: 0, max: 80, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'MPPT temperature', role: 'value', }, outVol: { min: 0, max: 60, unit_of_measurement: 'V', mult: 0.1, entity_type: 'sensor', device_class: 'voltage', name: 'PV output voltage', role: 'value', }, dcdc12vAmp: { min: 0, max: 13, unit_of_measurement: 'A', mult: 0.01, entity_type: 'sensor', device_class: 'current', name: 'DC12V30A output current, which is valid only for DELTA Pro', role: 'value', }, dc24vTemp: { min: 0, max: 80, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'DCDC24V temperature', role: 'value', }, }, switch: { carState: { entity_type: 'switch', device_class: 'switch', role: 'switch', name: 'Car charger switch setting', payload_off: 'off', payload_on: 'on', carState: { 0: 'off', 1: 'on', }, }, }, diagnostic: { faultCode: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Error code', faultCode: { 0: 'OK?', 1: 'mppt_fault', 2: 'car_fault', 4: 'dc24v_fault', }, }, xt60ChgType: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'XT60 charging type', xt60ChgType: { 0: 'not detected', 1: 'MPPT', 2: 'adapter', }, }, dc24vState: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'DCDC24 switch state', dc24vState: { 0: 'off', 1: 'on', }, }, chgPauseFlag: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'PV charging pause flag', chgPauseFlag: { 0: 'not stopped ?', 1: 'charging stopped', }, }, chgType: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Actual charging type', chgType: { 0: 'null', 1: 'adapter (adapter/DC source)', 2: 'MPPT (solar)', 3: 'AC (mains supply)', 4: 'gas', 5: 'wind', }, }, cfgChgType: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Configured charging type: This parameter is valid when xt60_chg_type is 0.', cfgChgType: { 0: 'auto', 1: 'MPPT', 2: 'adapter', }, }, chgState: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Charging state', chgState: { 0: 'disabled', 1: 'charging', 2: 'standby (DC charging stopped during AC charging)', }, }, }, string: { swVer: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Version number', }, }, level: { cfgDcChgCurrent: { min: 4, max: 8, unit_of_measurement: 'A', step: 2, mult: 0.001, entity_type: 'select', device_class: 'current', select: ['4A', '6A', '8A'], select_obj: { '4A': 4, '6A': 6, '8A': 8, }, states: { 4: '4A', 6: '6A', 8: '8A', }, name: 'On-board charging current', role: 'level', }, }, }, pd: { number: { wattsInSum: { min: 0, max: 4000, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Total input power', role: 'value', }, typec2Watts: { min: 0, max: 500, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Typec2 output power', role: 'value', }, usb1Watts: { min: 0, max: 500, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Common usb1 output power', role: 'value', }, chgPowerDc: { min: 0, max: 65000, unit_of_measurement: 'kWh', mult: 0.001, entity_type: 'sensor', device_class: 'energy', name: 'Cumulative DC power charged (adapter)', state_class: 'total_increasing', role: 'value', }, dsgPowerDc: { min: 0, max: 65000, unit_of_measurement: 'kWh', mult: 0.001, entity_type: 'sensor', device_class: 'energy', name: 'Cumulative DC power discharged', state_class: 'total_increasing', role: 'value', }, typccUsedTime: { min: 0, max: 9999999, unit_of_measurement: 'min', mult: 0.0166, entity_type: 'sensor', device_class: 'duration', name: 'Type-C use time', entity_category: 'diagnostic', role: 'value', }, typec2Temp: { min: 0, max: 80, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'Type-C 2 temperature', role: 'value', }, carUsedTime: { min: 0, max: 9999999, unit_of_measurement: 'min', mult: 0.0166, entity_type: 'sensor', device_class: 'duration', name: 'Car use time', entity_category: 'diagnostic', role: 'value', }, typec1Watts: { min: 0, max: 500, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Typec1 output power', role: 'value', }, soc: { min: 0, max: 100, unit_of_measurement: '%', mult: 1, entity_type: 'sensor', device_class: 'battery', name: 'Displayed SOC', role: 'value', }, wattsOutSum: { min: 0, max: 4000, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Total output power', role: 'value', }, invUsedTime: { min: 0, max: 9999999, unit_of_measurement: 'min', mult: 0.0166, entity_type: 'sensor', device_class: 'duration', name: 'Inverter use time', entity_category: 'diagnostic', role: 'value', }, typec1Temp: { min: 0, max: 80, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'Type-C 1 temperature', role: 'value', }, dsgPowerAc: { min: 0, max: 65000, unit_of_measurement: 'kWh', mult: 0.001, entity_type: 'sensor', device_class: 'energy', name: 'Cumulative AC power discharged', state_class: 'total_increasing', role: 'value', }, dcInUsedTime: { min: 0, max: 9999999, unit_of_measurement: 'min', mult: 0.0166, entity_type: 'sensor', device_class: 'duration', name: 'DC charging time', entity_category: 'diagnostic', role: 'value', }, chgPowerAc: { min: 0, max: 65000, unit_of_measurement: 'kWh', mult: 0.001, entity_type: 'sensor', device_class: 'energy', name: 'Cumulative AC power charged (wall socket)', state_class: 'total_increasing', role: 'value', }, remainTime: { min: 0, max: 143999, unit_of_measurement: 'min', mult: 1, entity_type: 'sensor', device_class: 'duration', name: 'Time remaining (min) > 0: remaining charging time; time remaining (min) < 0: remaining discharging time', role: 'value', }, chgSunPower: { min: 0, max: 65000, unit_of_measurement: 'kWh', mult: 0.001, entity_type: 'sensor', device_class: 'energy', name: 'Cumulative solar power charged', state_class: 'total_increasing', role: 'value', }, carTemp: { min: 0, max: 80, unit_of_measurement: '°C', mult: 1, entity_type: 'sensor', device_class: 'temperature', name: 'CAR temperature', role: 'value', }, qcUsb2Watts: { min: 0, max: 500, unit_of_measurement: 'W', mult: 0.1, entity_type: 'sensor', device_class: 'power', name: 'Quick charge usb2 output power', role: 'value', }, qcUsb1Watts: { min: 0, max: 500, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Quick charge usb1 output power', role: 'value', }, usbqcUsedTime: { min: 0, max: 9999999, unit_of_measurement: 'min', mult: 0.0166, entity_type: 'sensor', device_class: 'duration', name: 'USB QC use time', entity_category: 'diagnostic', role: 'value', }, usbUsedTime: { min: 0, max: 9999999, unit_of_measurement: 'min', mult: 0.0166, entity_type: 'sensor', device_class: 'duration', name: 'USB use time', entity_category: 'diagnostic', role: 'value', }, mpptUsedTime: { min: 0, max: 9999999, unit_of_measurement: 'min', mult: 0.0166, entity_type: 'sensor', device_class: 'duration', name: 'MPPT use time', entity_category: 'diagnostic', role: 'value', }, carWatts: { min: 0, max: 500, unit_of_measurement: 'W', mult: 0.1, entity_type: 'sensor', device_class: 'power', name: 'CAR output power', role: 'value', }, usb2Watts: { min: 0, max: 500, unit_of_measurement: 'W', mult: 1, entity_type: 'sensor', device_class: 'power', name: 'Common usb2 output power', role: 'value', }, }, string: { wifiVer: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Wi-Fi version', }, wirelessWatts: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Wireless charging output power (W)', }, model: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Product model', }, sysVer: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'System version', }, wifiRssi: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Wi-Fi signal intensity', }, }, level: { standByMode: { min: 0, max: 5999, unit_of_measurement: 'min', mult: 1, entity_type: 'select', device_class: 'duration', select: ['Never', '30 min', '1 hr', '2 hr', '4 hr', '6 hr', '12 hr'], select_obj: { Never: 0, '30 min': 30, '1 hr': 60, '2 hr': 120, '4 hr': 240, '6 hr': 360, '12 hr': 720, }, states: { 0: 'Never', 30: '30 min', 60: '1 hr', 120: '2 hr', 240: '4 hr', 360: '6 hr', 720: '12 hr', }, UNIT_TIMEOUT_OPTIONS: { Never: 0, '30 min': 30, '1 hr': 60, '2 hr': 120, '4 hr': 240, '6 hr': 360, '12 hr': 720, '24 hr': 1440, }, role: 'level', subrole: 'timer', name: 'Device standby time /min 0 Never standby 5999 Max value', standByMode: { 0: 'Never standby', 5999: 'Max value', }, }, lcdOffSec: { min: 0, max: 1800, unit_of_measurement: 's', mult: 1, entity_type: 'select', device_class: 'duration', select: ['Never', '10 sec', '30 sec', '1 min', '5 min', '30 min'], select_obj: { Never: 0, '10 sec': 10, '30 sec': 30, '1 min': 60, '5 min': 300, '30 min': 1800, }, states: { 0: 'Never', 10: '10 sec', 30: '30 sec', 60: '1 min', 300: '5 min', 1800: '30 min', }, role: 'level', subrole: 'timer', name: 'LCD screen-off duration: 0: never off', }, }, diagnostic: { carState: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'CAR button state', carState: { 0: 'off', 1: 'on', }, }, wifiAutoRcvy: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Wi-Fi auto mode', wifiAutoRcvy: { 0: 'default mode (STA)', 1: 'The Wi-Fi network is automatically restored to the last mode (STA/AP) after powering on', }, }, sysChgDsgState: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Charging/discharging state on screen', sysChgDsgState: { 0: 'discharged', 1: 'charged', }, }, errCode: { entity_type: 'text', entity_category: 'diagnostic', role: 'info', name: 'Global error code', errCode: { 0: 'OK?', }, }, }, switch: { beepState: { entity_type: 'switch', device_class: 'switch', role: 'switch', name: 'Beep status', payload_off: 'normal', payload_on: 'quiet', beepState: { 0: 'Normal', 1: 'Quiet', }, }, dcOutState: { entity_type: 'switch', device_class: 'switch', role: 'switch', name: 'DC button state', payload_off: 'off', payload_on: 'on', dcOutState: { 0: 'off', 1: 'on', }, }, }, icon: { lcdBrigh