UNPKG

iobroker.ecoflow-mqtt

Version:
73 lines (55 loc) 3.01 kB
# States for STREAM_INVERTER ### version: 1.4.9 [RuntimePropertyUpload](#RuntimePropertyUpload) [DisplayPropertyUpload](#DisplayPropertyUpload) ## RuntimePropertyUpload ### string | State | Name | |----------|------| |displayPropertyFullUploadPeriod| Display Property Full Upload Period | |displayPropertyIncrementalUploadPeriod| Display Property Incremental Upload Period | |runtimePropertyFullUploadPeriod| Runtime Property Full Upload Period | |runtimePropertyIncrementalUploadPeriod| Runtime Property Incremental Upload Period | ## DisplayPropertyUpload ### number | State | Min | Max | Unit | Mult | Name | |----------|:-------------:|:-------------:|:------:|:-----:|-----| |powGetPv2|0 | 600 | W | 1 | pow get pv2 | |plugInInfoPv2Amp|0 | 20 | A | 1 | plug in info pv2 current | |utcTimezone|-1200 | 1200 | | 1 | utc timezone | |powGetPv|0 | 600 | W | 1 | pow get pv | |invNtcTemp3|0 | 100 | °C | 1 | inv Ntc Temp 3 | |plugInInfoPvVol|0 | 60 | V | 1 | plug in info pv1 vol | |plugInInfoPvAmp|0 | 15 | A | 1 | plug in info pv1 current | |plugInInfoPv2Vol|0 | 60 | V | 1 | plug in info pv2 vol | |feedGridModePowLimit|0 | 1500 | W | 1 | feed Grid Mode Pow Limit | |gridConnectionVol|0 | 250 | V | 1 | grid Connection Vol | |gridConnectionFreq|0 | 62 | Hz | 1 | grid connection freq | |gridConnectionPower|0 | 2000 | W | 1 | Grid Connection Power | |feedGridModePowMax|0 | 1500 | W | 1 | feed Grid Mode Pow Max | |gridConnectionAmp|0 | 15 | A | 1 | grid connection amp | |gridConnectionReactivePower|0 | 1200 | var | 1 | Grid Connection Reactive Power | |gridConnectionPowerFactor|-1 | 1 | | 1 | grid connection power factor | |invTargetPwr|0 | 1200 | W | 1 | inv target pwr | |gridConnectionPowerFactorSetting|-1 | 1 | | 1 | grid connection power factor setting | ### string | State | Name | |----------|------| |utcTimezoneId| utc timezone id | |moduleWifiRssi| Wi-Fi signal intensity | |townCode| town code | |gridCodeVersion| grid Code Version | |countryCode| country code | ### diagnostic | State | Name | values | |----------|:-------------:|------| |utcSetMode| utc set mode | {0:OK?} | |gridConnectionSta| grid Connection Sta | {0:GRD_STA_NO_VALID,1:GRID_IN,2:GRID_NOT_ONLINE,3:FEED_GRID} | |gridCodeSelection| grid Code Selection | {0:NULL,1:AUSTRIA,2:SWITZER,3:POLAND,4:NETHERLANDS,5:VDE_4105,6:IEEE_1547,7:USER_DEFINED,8:NORWAY,9:CZECH_REPUBLIC,10:DENMARK,11:IRELAND,12:SWEDEN,13:LATVIA,14:GREECE_A,15:GREECE_B,16:PORTUGAL,17:ROMANIA,18:LITHUANIA,19:HUNGARY,20:ITALY,21:G98,22:G99,23:NTS_631,24:UNE_217001,25:UNE_217002,26:UTE_MAINLAND,27:UTE_50HZ_ISLAND,28:UTE_60HZ_ISLAND,29:BELGIUM,30:UKRAINE,31:SLOVENIA,32:BULGARIA,33:EU_GENERAL,1001:NORTH_AMERICA} | |factoryModeEnable| factory mode enable | {0:disabled?,1:enabled?} | |debugModeEnable| debug mode enable | {0:disabled?,1:enabled?} | ### array | State | Name | |----------|------| |devErrcodeList| dev Errcode List | |gridCurtailmentSignal| grid curtailment signal |