# States for RIVER3PLUS
### version: 1.3.1
[RuntimePropertyUpload](#RuntimePropertyUpload)
[DisplayPropertyUpload](#DisplayPropertyUpload)
## RuntimePropertyUpload
### diagnostic
| State | Name | values |
|----------|:-------------:|------|
|pcsWorkMode| pcs work mode | {0:OK?} |
|plugInInfoAcOutType| plug in info ac out type | {0:OK?} |
|bmsBalState| bms bal state | {0:OK?} |
|bmsAlmState| bms alm state | {0:OK?} |
|bmsProState| bms pro state | {0:OK?} |
|bmsFltState| bms flt state | {0:OK?} |
|bmsAlmState_2| bms alm state_2 | {0:OK?} |
|bmsProState_2| bms pro state_2 | {0:OK?} |
|invMainFsmstate| inv main fsmstate | {0:OK?} |
|l1MainFsmstate| l1 main fsmstate | {0:OK?} |
### number
| State | Min | Max | Unit | Mult | Name |
|----------|:-------------:|:-------------:|:------:|:-----:|-----|
|tempPcsDc|0 | 100 | °C | 1 | temp pcs dc |
|tempPcsAc|0 | 100 | °C | 1 | temp pcs ac |
|plugInInfoAcOutFreq|49 | 61 | Hz | 1 | plug in info ac out freq |
|plugInInfoAcOutVol|0 | 250 | V | 1 | plug in info ac out vol |
|plugInInfoAcInVol|0 | 250 | V | 1 | plug in info ac in vol |
|plugInInfoBmsVol|0 | 60 | V | 0.001 | plug in info bms vol |
|plugInInfoAcInAmp|0 | 30 | A | 1 | plug in info ac in amp |
|plugInInfoAcOutAmp|0 | 60 | A | 1 | plug in info ac out amp |
|bmsBattVol|0 | 60 | V | 0.001 | bms batt vol |
|bmsBattAmp|-80 | 80 | A | 1 | bms batt amp |
|bmsFullCap|0 | 80000 | mAh | 1 | bms full cap |
|bmsRemainCap|0 | 80000 | mAh | 1 | bms remain cap |
|bmsMinCellVol|0 | 5 | V | 0.001 | Minimum voltage of the main battery |
|bmsMaxCellVol|0 | 5 | V | 0.001 | bms max cell vol |
|cmsBattVol|0 | 60 | V | 0.001 | cms batt vol |
|cmsBattAmp|-80 | 80 | A | 0.001 | cms batt amp |
|cmsChgReqVol|0 | 60 | V | 0.001 | cms chg req vol |
|cmsChgReqAmp|0 | 80 | A | 0.001 | cms chg req amp |
|runtimePropertyFullUploadPeriod|0 | n/a | s | 1 | runtime property full upload period |
|runtimePropertyIncrementalUploadPeriod|0 | n/a | s | 1 | runtime property incremental upload period |
|dcdcChgReqCur|0 | 80 | A | 1 | dcdc chg req cur |
|llcRecvCmsChgReqVol|0 | 60 | V | 1 | llc recv cms chg req vol |
|tempPv|0 | 60 | °C | 1 | temp pv |
|plugInInfoPvVol|0 | 60 | V | 1 | plug in info pv vol |
|plugInInfoPvAmp|0 | 60 | A | 1 | plug in info pv amp |
|plugInInfo_12vVol|0 | 16 | V | 1 | plug in info_12v vol |
|plugInInfo_12vAmp|0 | 10 | A | 1 | plug in info_12v amp |
|llcBatVol|0 | 60 | V | 1 | llc bat vol |
|llcBatCur|-60 | 60 | A | 1 | llc bat cur |
|llcBusVol|0 | 60 | V | 0.1 | llc bus vol |
|plugInInfoDcpVol|0 | 60 | V | 1 | plug in info dcp vol |
|plugInInfoDcpAmp|0 | 60 | A | 1 | plug in info dcp amp |
### string
| State | Name |
|----------|------|
|pdMpptCommErr| pd mppt comm err |
|pdLlcCommErr| pd llc comm err |
|pdBmsCommErr| pd bms comm err |
|pdIotCommErr| pd iot comm err |
|pdFirmVer| pd firm ver |
|iotFirmVer| iot firm ver |
|mpptFirmVer| mppt firm ver |
|bmsFirmVer| bms firm ver |
|bmsErrCode| bms err code |
|displayPropertyFullUploadPeriod| display property full upload period |
|displayPropertyIncrementalUploadPeriod| display property incremental upload period |
|pvVinRef| pv vin ref |
### array
| State | Name |
|----------|------|
|runtimeStatisticsSum| runtime Statistics |
## DisplayPropertyUpload
### string
| State | Name |
|----------|------|
|errcode| errcode |
|pcsFanLevel| pcs fan level |
|dcOutOpen| dc out open |
|plugInInfoDcp2Detail| plug in info dcp2 detail |
|plugInInfoDcp2Sn| plug in info dcp2 sn |
|plugInInfoDcp2FirmVer| plug in info dcp2 firm ver |
|plugInInfoDcp2Resv| plug in info dcp2 resv |
|bmsErrCode| bms err code |
|errCodeRecordList| err code record list |
|pdErrCode| pd err code |
|mpptErrCode| mppt err code |
|llcInvErrCode| llc inv err code |
|upsAlram| ups alram |
|plugInInfoDcpDetail| plug in info dcp detail |
|plugInInfoDcpResv| plug in info dcp resv |
|plugInInfoDcpSn| plug in info dcp sn |
|plugInInfoDcpFirmVer| plug in info dcp firm ver |
|plugInInfoDcpErrCode| plug in info dcp err code |
|plugInInfoDcp2ErrCode| plug in info dcp2 err code |
|displayStatisticsSum| display statistics sum |
### number
| State | Min | Max | Unit | Mult | Name |
|----------|:-------------:|:-------------:|:------:|:-----:|-----|
|powInSumW|0 | 800 | W | 1 | Total input power |
|powOutSumW|0 | 1000 | W | 1 | Total output power |
|energyBackupStartSoc|0 | 100 | % | 1 | Backup reserve level |
|powGetQcusb1|0 | 120 | W | 1 | Real-time power of the USB 1 port |
|powGetQcusb2|0 | 120 | W | 1 | Real-time power of the USB 2 port |
|powGetTypec1|0 | 4000 | W | 1 | Real-time power of Type-C port 1 |
|powGetTypec2|0 | 4000 | W | 1 | Real-time power of Type-C port 2 |
|acAlwaysOnMiniSoc|0 | 100 | % | 1 | Sets the minimum SOC to enable the AC Always-on function |
|powGet_12v|0 | 60 | W | 1 | Real-time 12V power |
|powGetAc|0 | 8000 | W | 1 | Real-time AC power |
|powGetAcIn|0 | 8000 | W | 1 | Real-time AC input power |
|plugInInfoAcInFeq|0 | 61 | Hz | 1 | AC input frequency |
|powGetDcp2|0 | 60 | W | 1 | pow get dcp2 |
|powGetBms|0 | 8000 | W | 1 | pow get bms |
|acOutFreq|49 | 61 | Hz | 1 | AC output frequency |
|plugInInfoAcOutDsgPowMax|0 | 4000 | W | 1 | Maximum AC discharging power |
|bmsBattSoc|0 | 100 | % | 1 | SOC of the main battery |
|bmsBattSoh|0 | 100 | % | 1 | SOH of the main battery |
|bmsDesignCap|0 | 80000 | mAh | 1 | Battery capacity |
|bmsDsgRemTime|0 | 15999 | min | 1 | Remaining discharging time |
|bmsChgRemTime|0 | 15999 | min | 1 | Remaining charging time of the main battery |
|bmsMinCellTemp|0 | 80 | °C | 1 | Minimum temperature of the main battery |
|bmsMaxCellTemp|0 | 80 | °C | 1 | Temperature of the main battery |
|bmsMinMosTemp|0 | 100 | °C | 1 | bms min mos temp |
|bmsMaxMosTemp|0 | 100 | °C | 1 | bms max mos temp |
|cmsBattSoc|0 | 100 | % | 1 | Overall SOC |
|cmsBattSoh|0 | 100 | % | 1 | Overall SOH |
|cmsDsgRemTime|0 | 15999 | min | 1 | Remaining discharging time |
|cmsChgRemTime|0 | 15999 | min | 1 | Remaining charging time |
|timeTaskChangeCnt|0 | 60 | | 1 | time task change cnt |
|plugInInfoPvDcAmpMax|0 | 60 | A | 1 | plug in info pv dc amp max |
|lowPowerAlarm|0 | 60 | W | 1 | low power alarm |
|silenceChgWatt|0 | 600 | W | 1 | silence chg watt |
|powGetPv|0 | 60 | W | 1 | pow get pv |
|plugInInfoPvChgAmpMax|0 | 60 | A | 1 | plug in info pv chg amp max |
|plugInInfoPvChgVolMax|0 | 60 | V | 1 | plug in info pv chg vol max |
|powGetAcOut|0 | 60 | W | 1 | pow get ac out |
|powGetDcp|0 | 60 | W | 1 | pow get dcp |
|plugInInfoAcInChgHalPowMax|0 | 2000 | W | 1 | Maximum AC charging power |
### diagnostic
| State | Name | values |
|----------|:-------------:|------|
|energyBackupEn| Backup reserve function switch | {0:off,1:on} |
|flowInfoQcusb1| USB output port 1 switch status | {0:off,2:on} |
|flowInfoQcusb2| USB output port 2 switch status | {0:off,2:on} |
|flowInfoTypec1| Type-C port 1 switch status | {0:off,2:on} |
|flowInfoTypec2| Type-C port 2 switch status | {0:off,2:on} |
|acAlwaysOnFlag| ac always on flag | {0:OK?} |
|flowInfo_12v| flow info_12v | {0:off,2:on} |
|flowInfoAc2dc| flow info ac2dc | {0:off,2:on} |
|flowInfoDc2ac| flow info dc2ac | {0:off,2:on} |
|flowInfoAcIn| AC input switch status | {0:off,2:on} |
|plugInInfoAcInFlag| Indicates whether the AC charging port is connected | {0:disconnected,1:connected} |
|flowInfoDcp2In| flow info dcp2 in | {0:OK?} |
|flowInfoDcp2Out| flow info dcp2 out | {0:OK?} |
|plugInInfoDcp2InFlag| plug in info dcp2 in flag | {0:OK?} |
|plugInInfoDcp2DsgChgType| plug in info dcp2 dsg chg type | {0:OK?} |
|plugInInfoDcp2ChargerFlag| plug in info dcp2 charger flag | {0:OK?} |
|plugInInfoDcp2Type| plug in info dcp2 type | {0:OK?} |
|plugInInfoDcp2RunState| plug in info dcp2 run state | {0:OK?} |
|outputPowerOffMemory| output power off memory | {0:OFF?,1:ON?} |
|pvChgType| pv chg type | {0:OK?} |
|flowInfoBmsDsg| flow info bms dsg | {0:off,2:on} |
|flowInfoBmsChg| flow info bms chg | {0:off,2:on} |
|plugInInfoAcChargerFlag| Indicates whether the charger is connected to the AC port | {0:not charging?,1:charging?} |
|devSleepState| Sleep status | {0:Off?,1:On?} |
|llcHvLvFlag| High-voltage/Low-voltage AC identifier | {0:LV?,1:HV?} |
|cmsBmsRunState| On/Off status | {0:off,1:on} |
|bmsChgDsgState| Charging/Discharging status of the main battery | {0:not charging or discharging,1:discharging,2:charging} |
|cmsChgDsgState| Charging/Discharging status | {0:not charging or discharging,1:discharging,2:charging} |
|timeTaskConflictFlag| time task conflict flag | {0:no conflict?,1:conflict?} |
|ledMode| led mode | {0:OK?} |
|flowInfoPv| flow info pv | {0:OK?} |
|plugInInfoPvFlag| plug in info pv flag | {0:OK?} |
|plugInInfoPvType| plug in info pv type | {0:OK?} |
|plugInInfoPvChargerFlag| plug in info pv charger flag | {0:OK?} |
|flowInfoAcOut| flow info ac out | {0:OK?} |
|flowInfoDcpIn| flow info dcp in | {0:OK?} |
|flowInfoDcpOut| flow info dcp out | {0:OK?} |
|plugInInfoDcpInFlag| plug in info dcp in flag | {0:OK?} |
|plugInInfoDcpType| plug in info dcp type | {0:OK?} |
|plugInInfoDcpDsgChgType| plug in info dcp dsg chg type | {0:OK?} |
|plugInInfoDcpChargerFlag| plug in info dcp charger flag | {0:OK?} |
|plugInInfoDcpRunState| plug in info dcp run state | {0:OK?} |
### level
| State | Min | Max | Unit | Mult | Name | cmd |
|----------|:-------------:|:-------------:|:------:|:-----:|-----|------|
|devStandbyTime| 0 | 1440 | min | 1 | Device timeout (min) | {dest:2,cmdFunc:254,cmdId:17,dataLen:3} |
|screenOffTime| 0 | 1800 | s | 1 | Screen timeout (s) | {dest:2,cmdFunc:254,cmdId:17,dataLen:3} |
|acStandbyTime| 0 | 1440 | min | 1 | AC timeout (min) | {dest:2,cmdFunc:254,cmdId:17,dataLen:3} |
|plugInInfoAcInChgPowMax| 100 | 1500 | W | 1 | Maximum AC input power for charging | {dest:2,cmdFunc:254,cmdId:17,dataLen:4} |
|cmsMaxChgSoc| 50 | 100 | % | 1 | Charge limit | {dest:2,cmdFunc:254,cmdId:17,dataLen:3} |
|cmsMinDsgSoc| 0 | 30 | % | 1 | Discharge limit | {dest:2,cmdFunc:254,cmdId:17,dataLen:3} |
### switch
| State | off | on | Name | cmd |
|----------|:-------------:|:------:|------|------|
|xboostEn| off | on | X-Boost switch | {dest:2,cmdFunc:254,cmdId:17,dataLen:3} |
|enBeep| off | on | Beeper on/off. (true: on, false: off.) | {dest:2,cmdFunc:254,cmdId:17,dataLen:3} |
### array
| State | Name |
|----------|------|
|timeTaskCurrent| time task current |