SmartLithium (0x05)
Start Bit Nr of Bits Meaning Units Range NA Value Remark
32 32 BMS flags 0..0xFFFFFFFF VE_REG_BMS_FLAGs
64 16 SmartLithium error 0..0xFFFF VE_REG_SMART_LITHIUM_ERROR_FLAGS
80 7 Cell 1 0.01V 2.60..3.86 V 0x7F VE_REG_BATTERY_CELL_VOLTAGE*
87 7 Cell 2 0.01V 2.60..3.86 V 0x7F VE_REG_BATTERY_CELL_VOLTAGE*
94 7 Cell 3 0.01V 2.60..3.86 V 0x7F VE_REG_BATTERY_CELL_VOLTAGE*
101 7 Cell 4 0.01V 2.60..3.86 V 0x7F VE_REG_BATTERY_CELL_VOLTAGE*
108 7 Cell 5 0.01V 2.60..3.86 V 0x7F VE_REG_BATTERY_CELL_VOLTAGE*
115 7 Cell 6 0.01V 2.60..3.86 V 0x7F VE_REG_BATTERY_CELL_VOLTAGE*
122 7 Cell 7 0.01V 2.60..3.86 V 0x7F VE_REG_BATTERY_CELL_VOLTAGE*
129 7 Cell 8 0.01V 2.60..3.86 V 0x7F VE_REG_BATTERY_CELL_VOLTAGE*
136 12 Battery voltage 0.01V 0..40.94 V 0x0FFF VE_REG_DC_CHANNEL1_VOLTAGE
148 4 Balancer status 0..15 0x0F VE_REG_BALANCER_STATUS
152 7 Battery temperature 1°C -40..86 °C 0x7F VE_REG_BAT_TEMPERATURE Temperature = Record value - 40
159 1 Unused
VE_REG_BATTERY_CELL_VOLTAGE 0x00 ( 0) when cell voltage < 2.61V 0x01 ( 1) when cell voltage == 2.61V 0x7D (125) when cell voltage == 3.85V 0x7E (126) when cell voltage > 3.85 0x7F (127) when cell voltage is not available / unknown
*/
const VictronSensor = require ("./Victron/VictronSensor")
const VC = require("./Victron/VictronConstants")
const BitReader = require("./_BitReader")
const BALANCERSTATUS = {
0:"Unknown",
1:"Balanced",
2:"Balancing",
3:"Cell imbalance",
0xF:"Not applicable"
}
function _toCellVoltage(val){
return val==0x7F?NaN:2.6+(val/100)
}
class VictronSmartLithium extends VictronSensor{
static async identify(device){
return await this.identifyMode(device, 0x05)
}
async init() {
await super.init()
this.initMetadata()
}
initMetadata(){
this.addMetadatum('bmsFlags','', 'BMS Flags',
(buff)=>{return buff.readUInt32LE(0)})
this.addMetadatum('smartLithiumErrors','', 'Smart Lithium Errors Flags',
(buff)=>{return buff.readUInt16LE(4)})
this.addMetadatum('cell1Voltage','V', 'cell #1 voltage')
this.addMetadatum('cell2Voltage','V', 'cell #2 voltage')
this.addMetadatum('cell3Voltage','V', 'cell #3 voltage')
this.addMetadatum('cell4Voltage','V', 'cell #4 voltage')
this.addMetadatum('cell5Voltage','V', 'cell #5 voltage')
this.addMetadatum('cell6Voltage','V', 'cell #6 voltage')
this.addMetadatum('cell7Voltage','V', 'cell #7 voltage')
this.addMetadatum('cell8Voltage','V', 'cell #8 voltage')
this.addMetadatum('batteryVoltage','V', 'battery voltage',
(buff)=>{return this.NaNif((buff.readUInt16LE(13)&0xFFF),0xFFF)/100})
this.addMetadatum('balancerStatus','', 'balancer status', //TODO
(buff)=>{return BALANCERSTATUS[this.NaNif((buff.readUInt8(14)>>4),0xF)]})
this.addMetadatum('batteryTemp','K', 'battery temperature',
(buff)=>{return this.NaNif((buff.readUInt8(15)&0x7F),0x7F)+233.15})
}
emitValuesFrom(buffer){
super.emitValuesFrom(buffer)
const br = new BitReader(buffer.subarray(6,13))
for (let i = 0; i<8; i++)
this.emit(`cell${i+1}Voltage`,_toCellVoltage(br.read_unsigned_int(7)))
}
}
module.exports=VictronSmartLithium