/*(Lynx Smart) BMS (0x0A)
Start Bit Nr of Bits Meaning Units Range NA Value Remark
32 8 Error 0x0 VE_REG_BMS_ERROR
40 16 TTG 1min 0..45.5 days 0xFFFF VE_REG_TTG
56 16 Battery voltage 0.01V -327.68..327.66 V 0x7FFF VE_REG_DC_CHANNEL1_VOLTAGE
72 16 Battery current 0.1A -3276.8..3276.6 0x7FFF VE_REG_DC_CHANNEL1_CURRENT
88 16 IO status 0x0 VE_REG_BMS_IO
104 18 Warnings/Alarms 0x0 VE_REG_BMS_WARNINGS_ALARMS
122 10 SOC 0.1% 0..100.0% 0x3FF VE_REG_SOC
132 20 Consumed Ah 0.1Ah -104,857..0 Ah 0xFFFFF VE_REG_CAH Consumed Ah = -Record value
152 7 Temperature °C -40..86 °C 0x7F VE_REG_BAT_TEMPERATURE Temperature = Record value - 40
159 1 Unused*/
const VictronSensor = require ("./Victron/VictronSensor.js")
const VC = require("./Victron/VictronConstants.js")
const BitReader = require("./_BitReader")
class VictronLynxSmartBMS extends VictronSensor{
static async identify(device){
return await this.identifyMode(device, 0x0A)
}
async init() {
await super.init()
this.initMetadata()
}
initMetadata(){
this.addMetadatum('error','', 'error code',
(buff)=>{return buff.readUInt8(0)})
this.addMetadatum('ttg','s', 'time to go (in seconds)',
(buff)=>{return this.NaNif(buff.readUInt16LE(1),0xFFFF)*60})
this.addMetadatum('voltage','V', 'channel 1 voltage',
(buff)=>{return this.NaNif(buff.readInt16LE(3),0x7FFF)/100})
this.addMetadatum('current','A','channel 1 current',
(buff)=>{return this.NaNif(buff.readInt16LE(5),0x7FFF)/10})
this.addMetadatum('ioStatus','','IO Status', //TODO
(buff)=>{return buff.readUInt16LE(7)})
this.addMetadatum('warningsAndAlarms','','warnings and alarms')
this.addMetadatum('soc','','state of charge')
this.addMetadatum('consumedAh','Ah','amp-hours consumed')
this.addMetadatum('temp', 'K', 'battery temperature')
}
emitValuesFrom(buffer){
super.emitValuesFrom(buffer)
const br = new BitReader(buffer.subarray(9))
this.emit('warningsAndAlarms',br.read_unsigned_int(18))
this.emit('soc',
this.NaNif((br.read_unsigned_int(10),0x3FF)/1000))
this.emit('consumedAh',
this.NaNif(br.read_unsigned_int(20),0xFFFFF)/10 )
this.emit('temp',
this.NaNif( br.read_unsigned_int(7),0x7f) +233.15)
}
}
module.exports=VictronLynxSmartBMS