UNPKG

@willieee802/zigbee-herdsman-converters

Version:
125 lines 6.06 kB
"use strict"; var __createBinding = (this && this.__createBinding) || (Object.create ? (function(o, m, k, k2) { if (k2 === undefined) k2 = k; var desc = Object.getOwnPropertyDescriptor(m, k); if (!desc || ("get" in desc ? !m.__esModule : desc.writable || desc.configurable)) { desc = { enumerable: true, get: function() { return m[k]; } }; } Object.defineProperty(o, k2, desc); }) : (function(o, m, k, k2) { if (k2 === undefined) k2 = k; o[k2] = m[k]; })); var __setModuleDefault = (this && this.__setModuleDefault) || (Object.create ? (function(o, v) { Object.defineProperty(o, "default", { enumerable: true, value: v }); }) : function(o, v) { o["default"] = v; }); var __importStar = (this && this.__importStar) || function (mod) { if (mod && mod.__esModule) return mod; var result = {}; if (mod != null) for (var k in mod) if (k !== "default" && Object.prototype.hasOwnProperty.call(mod, k)) __createBinding(result, mod, k); __setModuleDefault(result, mod); return result; }; var __importDefault = (this && this.__importDefault) || function (mod) { return (mod && mod.__esModule) ? mod : { "default": mod }; }; Object.defineProperty(exports, "__esModule", { value: true }); const zigbee_herdsman_1 = require("@willieee802/zigbee-herdsman"); const exposes = __importStar(require("../lib/exposes")); const fromZigbee_1 = __importDefault(require("../converters/fromZigbee")); const toZigbee_1 = __importDefault(require("../converters/toZigbee")); const ota = __importStar(require("../lib/ota")); const constants = __importStar(require("../lib/constants")); const reporting = __importStar(require("../lib/reporting")); const e = exposes.presets; const ea = exposes.access; const definitions = [ { zigbeeModel: ["SPZB0001"], model: "SPZB0001", vendor: "Eurotronic", description: "Spirit Zigbee wireless heater thermostat", fromZigbee: [fromZigbee_1.default.eurotronic_thermostat, fromZigbee_1.default.battery], toZigbee: [ toZigbee_1.default.thermostat_occupied_heating_setpoint, toZigbee_1.default.thermostat_unoccupied_heating_setpoint, toZigbee_1.default.thermostat_local_temperature_calibration, toZigbee_1.default.eurotronic_host_flags, toZigbee_1.default.eurotronic_error_status, toZigbee_1.default.thermostat_setpoint_raise_lower, toZigbee_1.default.thermostat_control_sequence_of_operation, toZigbee_1.default.thermostat_remote_sensing, toZigbee_1.default.thermostat_local_temperature, toZigbee_1.default.thermostat_running_state, toZigbee_1.default.eurotronic_current_heating_setpoint, toZigbee_1.default.eurotronic_trv_mode, toZigbee_1.default.eurotronic_valve_position, toZigbee_1.default.eurotronic_child_lock, toZigbee_1.default.eurotronic_mirror_display, ], exposes: [ e.battery(), e.child_lock(), e .climate() .withSetpoint("occupied_heating_setpoint", 5, 30, 0.5) .withLocalTemperature() .withSystemMode(["off", "auto", "heat"]) .withRunningState(["idle", "heat"]) .withLocalTemperatureCalibration() .withPiHeatingDemand(), e .enum("trv_mode", exposes.access.ALL, [1, 2]) .withDescription("Select between direct control of the valve via the `valve_position` or automatic control of the " + "valve based on the `current_heating_setpoint`. For manual control set the value to 1, for automatic control set the value " + "to 2 (the default). When switched to manual mode the display shows a value from 0 (valve closed) to 100 (valve fully open) " + "and the buttons on the device are disabled."), e .numeric("valve_position", exposes.access.ALL) .withValueMin(0) .withValueMax(255) .withDescription("Directly control the radiator valve when `trv_mode` is set to 1. The values range from 0 (valve " + "closed) to 255 (valve fully open)"), e .binary("mirror_display", ea.ALL, "ON", "OFF") .withDescription("Mirror display of the thermostat. Useful when it is " + "mounted in a way where the display is presented upside down."), ], ota: ota.zigbeeOTA, configure: async (device, coordinatorEndpoint) => { const endpoint = device.getEndpoint(1); const options = { manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.NXP_SEMICONDUCTORS, }; await reporting.bind(endpoint, coordinatorEndpoint, [ "genPowerCfg", "hvacThermostat", ]); await reporting.thermostatTemperature(endpoint); await reporting.thermostatPIHeatingDemand(endpoint); await reporting.thermostatOccupiedHeatingSetpoint(endpoint); await reporting.thermostatUnoccupiedHeatingSetpoint(endpoint); await endpoint.configureReporting("hvacThermostat", [ { attribute: { ID: 0x4003, type: 41 }, minimumReportInterval: 0, maximumReportInterval: constants.repInterval.HOUR, reportableChange: 25, }, ], options); await endpoint.configureReporting("hvacThermostat", [ { attribute: { ID: 0x4008, type: 34 }, minimumReportInterval: 0, maximumReportInterval: constants.repInterval.HOUR, reportableChange: 1, }, ], options); }, }, ]; exports.default = definitions; module.exports = definitions; //# sourceMappingURL=eurotronic.js.map