const { toMac, signInt, msbLsb } = require('../utils');
// --- 1. DEFINE LOCAL FUNCTIONS ---
// These are defined as local variables so they can call each other easily.
module.exports = (globalDevices) => {
const get_write_buffer_size = (firmware) => {
return 22;
};
const get_config_map = (firmware) => {
console.log('Generating sync map for firmware version', firmware);
return {
"core_version": {
"read_index": 3,
"descriptions": {
"title": "Core Version",
"main_caption": "The version of the core communication stack."
},
"validator": {
"type": "uint8"
},
"tags": [
"system"
]
},
"firmware_version": {
"read_index": 4,
"descriptions": {
"title": "Firmware Version",
"main_caption": "The application-specific firmware version."
},
"validator": {
"type": "uint8"
},
"tags": [
"system"
]
},
"sensor_type": {
"read_index": 5,
"descriptions": {
"title": "Sensor Type",
"main_caption": "The hardware identifier for the specific sensor model."
},
"validator": {
"type": "uint16be"
},
"tags": [
"system"
]
},
"tx_lifetime_counter": {
"read_index": 7,
"descriptions": {
"title": "Sampling Interval",
"main_caption": "Set how often will the sensor transmit measurement data. Note: For this sensor, this value functions as the sampling interval rather than a traditional delay.",
"sub_caption": "Default value: 20 milliseconds."
},
"validator": {
"type": "uint32be"
},
"tags": [
"diagnostics"
]
},
"hardware_id": {
"read_index": 11,
"length": 3,
"descriptions": {
"title": "Hardware ID",
"main_caption": "A unique 3-byte hardware identifier."
},
"validator": {
"type": "buffer"
},
"tags": [
"system"
]
},
"network_id": {
"read_index": 14,
"write_index": 3,
"length": 2,
"descriptions": {
"title": "Network ID",
"main_caption": ""
},
"default_value": "7fff",
"validator": {
"type": "hex",
"length": 4
},
"html_id": "pan_id",
"tags": [
"communications"
]
},
"destination_address": {
"read_index": 16,
"write_index": 5,
"length": 4,
"descriptions": {
"title": "Destination Address",
"main_caption": ""
},
"default_value": "0000ffff",
"validator": {
"type": "mac",
"length": 8
},
"html_id": "destination",
"tags": [
"communications"
]
},
"node_id": {
"read_index": 20,
"write_index": 9,
"descriptions": {
"title": "Node ID",
"main_caption": ""
},
"default_value": "0",
"validator": {
"type": "uint8",
"min": 0,
"max": 255,
"generated": true
},
"html_id": "node_id",
"tags": [
"generic"
]
},
"report_rate": {
"read_index": 21,
"write_index": 10,
"descriptions": {
"title": "Delay",
"main_caption": ""
},
"default_value": "600",
"validator": {
"type": "uint32be",
"min": 0,
"max": 65535,
"generated": true
},
"html_id": "delay",
"tags": [
"generic"
]
},
"calibration_days": {
"read_index": 25,
"descriptions": {
"title": "",
"main_caption": ""
},
"default_value": 0,
"validator": {
"type": "uint8",
"min": 0,
"max": 255,
},
"converter": {
"units": " days"
}
},
"sensor_update_rate": {
"read_index": 26,
"descriptions": {
"title": "",
"main_caption": ""
},
"default_value": 0,
"validator": {
"type": "uint16be",
"min": 0,
"max": 65535,
},
"converter": {
"units": " seconds"
}
},
"heater_duration": {
"read_index": 28,
"descriptions": {
"title": "",
"main_caption": ""
},
"default_value": 0,
"validator": {
"type": "uint16be",
"min": 0,
"max": 65535,
},
"converter": {
"units": " msec"
}
},
"heater_temperature": {
"read_index": 30,
"descriptions": {
"title": "",
"main_caption": ""
},
"default_value": 0,
"validator": {
"type": "uint16be",
"min": 0,
"max": 65535,
},
"converter": {
"units": " C"
}
},
"h2_sensor_boot_time": {
"read_index": 32,
"write_index": 21,
"descriptions": {
"title": "",
"main_caption": ""
},
"default_value": 15,
"validator": {
"type": "uint8",
"min": 15,
"max": 255,
},
"converter": {
"units": " seconds"
},
"html_id": "h2_sensor_boot_time_547"
}
};
};
const sync_parse = (rep_buffer) => {
let response = {
'human_readable': {},
'machine_values': {}
};
// Get the map based on the sensor type byte
const sync_map = get_config_map(rep_buffer[4]);
for (const [key, config] of Object.entries(sync_map)) {
// Destructure 'type' from inside 'validator' and rename 'read_index' to 'idx'
const { read_index: idx, length, validator: { type } = {}, converter, options } = config;
// If for some reason a config doesn't have a validator/type, skip it
if (!type) continue;
switch (type) {
case 'uint8':
response.machine_values[key] = rep_buffer[idx];
break;
case 'uint16be':
response.machine_values[key] = rep_buffer.readUInt16BE(idx);
break;
case 'uint32be':
response.machine_values[key] = rep_buffer.readUInt32BE(idx);
break;
case 'buffer':
response.machine_values[key] = rep_buffer.subarray(idx, idx + length);
break;
case 'hex':
response.machine_values[key] = rep_buffer.subarray(idx, idx + length).toString('hex');
break;
case 'mac':
response.machine_values[key] = rep_buffer.subarray(idx, idx + length).toString('hex');
break;
}
let human_value = response.machine_values[key];
if(options && options[response.machine_values[key]]){
human_value = options[response.machine_values[key]];
}else{
if(converter && converter.multiplier){
human_value = human_value * converter.multiplier;
}
if(converter && converter.units){
human_value = human_value + converter.units;
}
}
response.human_readable[key] = human_value;
}
if (Object.hasOwn(response.machine_values, 'destination_address') && response.machine_values.destination_address.toLowerCase() === '00000000') {
console.log('##############################');
console.log('#########Dest Override########');
console.log('##############################');
response.destination_address = "0000ffff";
};
return response;
};
const parse = (payload, parsed, mac) => {
let bme_status_byte = payload[7] & 0x07;
let hydro_status_byte = payload[7] & (1 << 3);
let bme_status = 'sucess';
switch(bme_status_byte){
case 1:
bme_status = {
error: 'Connection failed',
value: bme_status_byte
}
break;
case 2:
bme_status = {
error: 'No new data',
value: bme_status_byte
}
break;
case 3:
bme_status = {
error: 'Sensor not found',
value: bme_status_byte
}
break;
case 4:
bme_status = {
error: 'Sensor communication failed',
value: bme_status_byte
}
break;
case 5:
bme_status = {
error: 'Sensor generic error',
value: bme_status_byte
}
break;
}
let hydro_status = hydro_status_byte?'Failure':'sucess';
return{
environment_status: bme_status,
hydro_status: hydro_status,
h2_concentration_ppm: payload.slice(8, 12).reduce(msbLsb),
temperature: signInt(payload.slice(12, 14).reduce(msbLsb), 32) / 100,
pressure: payload.slice(14, 18).reduce(msbLsb) / 100,
humidity: payload.slice(18, 22).reduce(msbLsb) / 1000,
resistance: payload.slice(22, 26).reduce(msbLsb),
iaq: payload.slice(26, 28).reduce(msbLsb),
co2_eqv: payload.slice(28, 30).reduce(msbLsb),
breath_voc: payload.slice(30, 34).reduce(msbLsb) / 100,
static_iaq: payload.slice(34, 38).reduce(msbLsb) / 100,
iaq_accuracy: payload[38]
};
};
// --- 2. EXPORT THE MODULE ---
// Export the module with all the necessary functions and properties
// that need to be called from outside the scrip
return {
type: 547,
name: 'Wireless Hydrogen Enviorment Sensor',
parse,
get_write_buffer_size,
get_config_map,
sync_parse
};
};