# READ ## Effect Returns next value(s) that has been stored in the program source by using `DATA` instructions. ## Syntax `READ <Variable>,<Variable>...` _Note: Parameters can not end with a comma alone._ ## Parameter `<Variable>` is a variable that matches with the datatype stored in `DATA` instruction. After `READ` instruction is executed the data pointer will automatically move to next item. Data pointer can be moved manually by using `RESTORE` instruction. ## Example ```basic 10 READ A$ 20 PRINT A$ 30 READ A,B 40 PRINT A 50 PRINT B 60 DATA "TEST",10,20   RUN TEST 10 20 ``` ## Related to `DATA`, `DIM`, `RESTORE` ## Compatibility MSX-BASIC 1.0 or higher ## Source Retrieved from "https://www.msx.org/wiki/READ"