# ON INTERVAL GOSUB ## Effect Calls a subroutine after the specified timeout has been elapsed. ## Syntax `ON INTERVAL=<TimeoutNumber> GOSUB<LineNumber>` ## Parameters `<TimeoutNumber>` is a number to specify the timeout, which is equal to number*1/60 (or number*1/50) seconds. `<LineNumber>` is a program line number of your subroutine. The subroutine must be terminated with the `RETURN` instruction. ## Examples ```basic 10 ' Interrupt once every second on all MSX models 15 ON INTERVAL=60-10*(PEEK(&H2B)\128) GOSUB 50 20 INTERVAL ON 30 X=X+1:IF INKEY$="" THEN 30 40 END 50 PRINT X:RETURN ``` ```basic 10 ON INTERVAL=300 GOSUB 60 20 INTERVAL ON 30 FOR I=1 TO 10000:NEXT I 40 INTERVAL OFF 50 END 60 K=K+6:PRINT K;"seconds" 70 RETURN   RUN 6 seconds 12 seconds 18 seconds 24 seconds ``` ## Related to `INTERVAL`, `RETURN`, `TIME` ## Compatibility MSX-BASIC 1.0 or higher ## Source Retrieved from "https://www.msx.org/wiki/ON_INTERVAL_GOSUB"