Module for using the WaveShare UPS Raspberry Pi Hat that has an embedded Texas Instruments INA219 sensor.
106 lines (100 loc) • 3.05 kB
JavaScript
/**
* @class BusVoltageModel
*
* @summary
* BUS VOLTAGE REGISTER: PDF REF: Figure 24 pg. 23
*
* @description
* BIT 1: Conversion ready<br />
* CNVR is 1 when data from conversion is available at the data registers
* reading the Power Register resets this to 0
* <br /><br />
* BIT 0: Math Overflow Flag<br />
* OVF is set when Power or Current calculations are out of range
* probably need board reset after seeing this
*/
import BaseRegisterModel from "../../BaseModels/BaseRegisterModel.js";
import Big from 'big.js';
class BusVoltageModel extends BaseRegisterModel {
constructor() {
super("BusVoltage");
}
/**
* @type {object}
*
* @summary
* If useFullReturn is true then the labels are added to the return
* object.
*
* @description
* These are labels the directly match the reference sensor PDF doc. When
* debugging or in case UI desires it, arrays of labels and bits in the
* register will be matched.
*/
bitLabels = [
'BD12', 'BD11', 'BD10', 'BD9',
'BD8', 'BD7', 'BD6', 'BD5',
'BD4', 'BD3', 'BD2', 'BD1',
'BD0',
'-',
'CNVR',
'OVF'
];
/**
* @type {object}
*
* @summary
* the type of value in the register
*
* @description
* Currently only english language value types
*/
measurement = {
en: {
full: "volt",
plural: "volts",
short: "V"
}
}
/**
* @method BusVoltageModel#calculateValue
*
* @summary
* Get the Bus voltage. Takes the raw register value and formats it
*
* @description
* Calculates the Bus voltage in volts
* The BusVoltage is set with the configuration register to be
* either 16v or 32v this means the Full Scale Range to try and
* store in bits 15 -> 3
*
* Bus voltage LSB is 4mV at both 32V and 16V settings.
*
* see pg 23 in PDF of ina219, 8.6.3.2 Bus Voltage Register (address = 02h)
*
* Note: the register value is shifted 3 bits to the left
* bit 2 '-',
* bit 1 'CNVR',
* bit 0 'OVF'
*
* TODO: Check if value is correct via bit 0
* POST-IT: Need to play with with this to see what if anything changes
* internally when it captures the bus voltage.
*
* @param {number} currentValue the current measurement in the register
*
* @returns {object} returns calculated values
*/
calculateValue = function (currentValue) {
// get bits 15 to 3
let shifted = currentValue >> 3;
// multiply by 4mV per bit
let calculation = shifted * 0.004;
let formatted = new Big(calculation).toFixed(this.defaultPrecision);
return {
rawNumber: calculation,
withPrecision: formatted
}
}
}
export default new BusVoltageModel();