@eflexsystems/node-open-protocol
Version:
A library to interface with Power Tools using the Atlas Copco Open Protocol
186 lines • 5.64 kB
JSON
{
"strategy": {
"1": "Torque control",
"2": "Torque control / angle monitoring",
"3": "Torque control / angle control AND",
"4": "Angle control / torque monitoring",
"5": "DS control",
"6": "DS control torque monitoring",
"7": "Reverse angle",
"8": "Reverse torque",
"9": "Click wrench",
"10": "Rotate spindle forward",
"11": "Torque control angle control OR",
"12": "Rotate spindle reverse",
"13": "Home position forward",
"14": "EP Monitoring",
"15": "Yield",
"16": "EP Fixed",
"17": "EP Control",
"18": "EP Angle shutoff",
"19": "Yield / torque control OR",
"20": "Snug gradient",
"21": "Residual torque / Time",
"22": "Residual torque / Angle",
"23": "Breakaway peak",
"24": "Loose and tightening",
"25": "Home position reverse",
"26": "PVT comp with Snug",
"99": "No strategy"
},
"strategyOptions": {
"0": "Torque",
"1": "Angle",
"2": "Batch",
"3": "PVT Monitoring",
"4": "PVT Compensate",
"5": "Self-tap",
"6": "Rundown",
"7": "CM",
"8": "DS control",
"9": "Click Wrench",
"10": "RBW Monitoring"
},
"tighteningErrorStatus": {
"0": "Rundown angle max shut off",
"1": "Rundown angle min shut off",
"2": "Torque max shut off",
"3": "Angle max shut off",
"4": "Self-tap torque max shut off",
"5": "Self-tap torque min shut off",
"6": "Prevail torque max shut off",
"7": "Prevail torque min shut off",
"8": "Prevail torque compensate overflow",
"9": "Current monitoring max shut off",
"10": "Post view torque min torque shut off",
"11": "Post view torque max torque shut off",
"12": "Post view torque Angle too small",
"13": "Trigger lost",
"14": "Torque less than target",
"15": "Tool hot",
"16": "Multistage abort",
"17": "Rehit",
"18": "DS measure failed",
"19": "Current limit reached",
"20": "End Time out shutoff",
"21": "Remove fastener limit exceeded",
"22": "Disable drive",
"23": "Transducer lost",
"24": "Transducer shorted",
"25": "Transducer corrupt",
"26": "Sync timeout",
"27": "Dynamic current monitoring min",
"28": "Dynamic current monitoring max",
"29": "Angle max monitor",
"30": "Yield nut off",
"31": "Yield too few samples"
},
"tighteningErrorStatus2": {
"0": "Drive deactivated",
"1": "Tool stall",
"2": "Drive hot",
"3": "Gradient monitoring high",
"4": "Gradient monitoring low",
"5": "Reaction bar failed",
"6": "Snug Max",
"7": "Cycle abort",
"8": "Necking failure",
"9": "Effective loosening",
"10": "Over speed",
"11": "No residual Torque",
"12": "Positioning fail",
"13": "Snug Mon. Low",
"14": "Snug Mon. High",
"15": "Dynamic Min. Current",
"16": "Dynamic Mac Current",
"17": "Latent result",
"18": "Reserved",
"19": "Reserved",
"20": "Reserved",
"21": "Reserved",
"22": "Reserved",
"23": "Reserved",
"24": "Reserved",
"25": "Reserved",
"26": "Reserved",
"27": "Reserved",
"28": "Reserved",
"29": "Reserved",
"30": "Reserved",
"32": "Reserved"
},
"status": {
"0": "LOW",
"1": "OK",
"2": "HIGH"
},
"torqueValuesUnit": {
"1": "Nm",
"2": "Lbf.ft",
"3": "Lbf.In",
"4": "Kpm",
"5": "Kgf.cm",
"6": "ozf.in",
"7": "%",
"8": "Ncm"
},
"resultType": {
"1": "Tightening",
"2": "Loosening",
"3": "Batch Increment",
"4": "Batch decrement",
"5": "Bypass parameter set result",
"6": "Abort Job result",
"7": "Sync tightening",
"8": "Reference setup"
},
"serializer-torqueValuesUnit": {
"Nm": 1,
"Lbf.ft": 2,
"Lbf.In": 3,
"Kpm": 4,
"Kgf.cm": 5,
"ozf.in": 6,
"%": 7,
"Ncm": 8
},
"serializer-resultType": {
"Tightening": 1,
"Loosening": 2,
"Batch Increment": 3,
"Batch decrement": 4,
"Bypass parameter set result": 5,
"Abort Job result": 6,
"Sync tightening": 7,
"Reference setup": 8
},
"serializer-strategy": {
"Torque control": 1,
"Torque control / angle monitoring": 2,
"Torque control / angle control AND": 3,
"Angle control / torque monitoring": 4,
"DS control": 5,
"DS control torque monitoring": 6,
"Reverse angle": 7,
"Reverse torque": 8,
"Click wrench": 9,
"Rotate spindle forward": 10,
"Torque control angle control OR": 11,
"Rotate spindle reverse": 12,
"Home position forward": 13,
"EP Monitoring": 14,
"Yield": 15,
"EP Fixed": 16,
"EP Control": 17,
"EP Angle shutoff": 18,
"Yield / torque control OR": 19,
"Snug gradient": 20,
"Residual torque / Time": 21,
"Residual torque / Angle": 22,
"Breakaway peak": 23,
"Loose and tightening": 24,
"Home position reverse": 25,
"PVT comp with Snug": 26,
"No strategy": 99
}
}