UNPKG

@eflexsystems/node-open-protocol

Version:

A library to interface with Power Tools using the Atlas Copco Open Protocol

186 lines 5.64 kB
{ "strategy": { "1": "Torque control", "2": "Torque control / angle monitoring", "3": "Torque control / angle control AND", "4": "Angle control / torque monitoring", "5": "DS control", "6": "DS control torque monitoring", "7": "Reverse angle", "8": "Reverse torque", "9": "Click wrench", "10": "Rotate spindle forward", "11": "Torque control angle control OR", "12": "Rotate spindle reverse", "13": "Home position forward", "14": "EP Monitoring", "15": "Yield", "16": "EP Fixed", "17": "EP Control", "18": "EP Angle shutoff", "19": "Yield / torque control OR", "20": "Snug gradient", "21": "Residual torque / Time", "22": "Residual torque / Angle", "23": "Breakaway peak", "24": "Loose and tightening", "25": "Home position reverse", "26": "PVT comp with Snug", "99": "No strategy" }, "strategyOptions": { "0": "Torque", "1": "Angle", "2": "Batch", "3": "PVT Monitoring", "4": "PVT Compensate", "5": "Self-tap", "6": "Rundown", "7": "CM", "8": "DS control", "9": "Click Wrench", "10": "RBW Monitoring" }, "tighteningErrorStatus": { "0": "Rundown angle max shut off", "1": "Rundown angle min shut off", "2": "Torque max shut off", "3": "Angle max shut off", "4": "Self-tap torque max shut off", "5": "Self-tap torque min shut off", "6": "Prevail torque max shut off", "7": "Prevail torque min shut off", "8": "Prevail torque compensate overflow", "9": "Current monitoring max shut off", "10": "Post view torque min torque shut off", "11": "Post view torque max torque shut off", "12": "Post view torque Angle too small", "13": "Trigger lost", "14": "Torque less than target", "15": "Tool hot", "16": "Multistage abort", "17": "Rehit", "18": "DS measure failed", "19": "Current limit reached", "20": "End Time out shutoff", "21": "Remove fastener limit exceeded", "22": "Disable drive", "23": "Transducer lost", "24": "Transducer shorted", "25": "Transducer corrupt", "26": "Sync timeout", "27": "Dynamic current monitoring min", "28": "Dynamic current monitoring max", "29": "Angle max monitor", "30": "Yield nut off", "31": "Yield too few samples" }, "tighteningErrorStatus2": { "0": "Drive deactivated", "1": "Tool stall", "2": "Drive hot", "3": "Gradient monitoring high", "4": "Gradient monitoring low", "5": "Reaction bar failed", "6": "Snug Max", "7": "Cycle abort", "8": "Necking failure", "9": "Effective loosening", "10": "Over speed", "11": "No residual Torque", "12": "Positioning fail", "13": "Snug Mon. Low", "14": "Snug Mon. High", "15": "Dynamic Min. Current", "16": "Dynamic Mac Current", "17": "Latent result", "18": "Reserved", "19": "Reserved", "20": "Reserved", "21": "Reserved", "22": "Reserved", "23": "Reserved", "24": "Reserved", "25": "Reserved", "26": "Reserved", "27": "Reserved", "28": "Reserved", "29": "Reserved", "30": "Reserved", "32": "Reserved" }, "status": { "0": "LOW", "1": "OK", "2": "HIGH" }, "torqueValuesUnit": { "1": "Nm", "2": "Lbf.ft", "3": "Lbf.In", "4": "Kpm", "5": "Kgf.cm", "6": "ozf.in", "7": "%", "8": "Ncm" }, "resultType": { "1": "Tightening", "2": "Loosening", "3": "Batch Increment", "4": "Batch decrement", "5": "Bypass parameter set result", "6": "Abort Job result", "7": "Sync tightening", "8": "Reference setup" }, "serializer-torqueValuesUnit": { "Nm": 1, "Lbf.ft": 2, "Lbf.In": 3, "Kpm": 4, "Kgf.cm": 5, "ozf.in": 6, "%": 7, "Ncm": 8 }, "serializer-resultType": { "Tightening": 1, "Loosening": 2, "Batch Increment": 3, "Batch decrement": 4, "Bypass parameter set result": 5, "Abort Job result": 6, "Sync tightening": 7, "Reference setup": 8 }, "serializer-strategy": { "Torque control": 1, "Torque control / angle monitoring": 2, "Torque control / angle control AND": 3, "Angle control / torque monitoring": 4, "DS control": 5, "DS control torque monitoring": 6, "Reverse angle": 7, "Reverse torque": 8, "Click wrench": 9, "Rotate spindle forward": 10, "Torque control angle control OR": 11, "Rotate spindle reverse": 12, "Home position forward": 13, "EP Monitoring": 14, "Yield": 15, "EP Fixed": 16, "EP Control": 17, "EP Angle shutoff": 18, "Yield / torque control OR": 19, "Snug gradient": 20, "Residual torque / Time": 21, "Residual torque / Angle": 22, "Breakaway peak": 23, "Loose and tightening": 24, "Home position reverse": 25, "PVT comp with Snug": 26, "No strategy": 99 } }